Tag
Điều hòa
6 articles
ArticleHow to read AC manifold gauges: refrigeration cycle and R32 P-T chartTo read AC manifold gauges correctly, read the suction pressure on the blue gauge, convert that number into the refrigerant's boiling temperature using the pressure-temperature (P-…
ArticleAir conditioner installation safety: power, R32 and outdoor unitsAir conditioner installation safety revolves around three hazards: 220 V power and charged capacitors inside the unit, high-pressure refrigerant that can cause cold burns (and fire…
ArticleRecharging AC refrigerant: measure, find the leak, then chargeRecharging an air conditioner with refrigerant is only truly needed when the unit is short of refrigerant, and because refrigerant circulates in a sealed loop, being short almost a…
ArticleAir conditioner leaking water inside: 7 causes and how to checkAn air conditioner leaking water inside the room is, in most cases, condensate that cannot get out: the drain line or drain pan is blocked, the indoor unit is hung with the wrong t…
ArticleAir conditioner not cooling: 9 causes, self-checks and when to callAn air conditioner that is not cooling usually has one of three groups of causes: wrong settings or a room with too much heat load; a dirty unit (filters, indoor coil, outdoor unit…
ArticleHow to clean an air conditioner at home: how often, 2026 pricesCleaning an air conditioner at home has two parts: the owner washes the air filters every 2–4 weeks, while a technician pressure-washes the indoor coil and the outdoor unit and cle…