A traction elevator is a car and a counterweight hanging from the two ends of a set of hoist ropes that pass over the sheave of a traction machine; both run along guide rails, while the overspeed governor, the safety gear and the buffers in the pit form the anti-fall chain. A machine-room elevator keeps the machine and controller in a separate room above the shaft; a machine-room-less (MRL) elevator puts the machine at the top of the shaft and the controller in the top landing door frame or a cabinet next to the shaft. This lesson walks you from the top of the shaft to the bottom so you can recognise each part on a real lift.
By the end of this lesson, you will be able to:
- Point out the location and job of the 8 main parts: traction machine, sheave, hoist ropes, counterweight, guide rails, overspeed governor, safety gear and buffers.
- Tell a machine-room elevator from an MRL elevator using 5 signs you can see on site.
- Explain the anti-fall chain: overspeed, the governor cuts the circuit, the safety gear grips the rails, the buffers stop the car at the end of travel.
- Work out rope speed, sheave revolutions and the maximum number of passengers from the data plate.
- Compare passenger, home and freight lifts by load, speed and what to watch for during maintenance.
Learning the elevator trade? Elevator construction is step 2 of the roadmap, after hoistway safety and before control circuits and drives. See the 8-step elevator technician roadmap.
How a traction elevator works
Most lifts in apartment blocks, offices and hospitals in Vietnam are friction-driven traction elevators.
Car, counterweight and traction sheave
The hoist ropes are not wound onto a drum; they simply sit in the grooves of the traction sheave. One end of the ropes is attached to the car, the other to the counterweight. When the motor turns the sheave, friction between the grooves and the ropes drags the ropes along: when the car goes up, the counterweight goes down, and the other way round.
Why there is a counterweight
The counterweight balances the empty car plus part of the rated load, so the motor only has to lift the difference instead of the whole car. How to predict which way the car drifts when the brake is released is covered in the lesson stuck in an elevator: how technicians rescue safely.
The three zones of an elevator
- Top: the machine room (machine-room lift) or the shaft headroom (MRL lift), with the traction machine, brake, overspeed governor and controller.
- Hoistway: car, counterweight, guide rails, hoist ropes, travelling cable (flat cable) and landing doors.
- Pit: car and counterweight buffers, the governor rope tension pulley, the pit stop switch and the pit ladder.
Traction machine, sheave and hoist ropes
This is the group of parts that creates motion. In an older machine room there is usually one machine per lift, each with a large sheave, and the controller stands against the wall (Figure 1).
Geared and gearless machines
A geared machine uses a high-speed motor coupled to a reduction gearbox (usually worm and wheel) that drives the sheave. You see it on older lifts; it is noisier and needs gearbox oil changes. A gearless machine uses a slow-turning permanent-magnet synchronous motor with the sheave mounted directly on the motor shaft, so it is compact, quiet and more efficient; most new lifts, especially MRL lifts, use this type. Figure 2 shows a gearless machine; the two cylindrical units on top are most likely electromagnetic brake coils.
Photo: Darklanlan / Wikimedia Commons, CC BY 4.0
The machine brake
An elevator brake is normally closed: springs press the brake shoes onto a disc or drum, and the electromagnet only releases the brake when there is a run command. If power fails, the brake closes by itself. New machines usually have two independent brake units, so if one fails the other can still hold the car.
Traction sheave and grooves
The traction sheave has several parallel grooves, one per rope. The grooves have a special profile (undercut U groove or V groove) to create enough friction. Uneven groove wear makes the ropes wear quickly and can cause slipping. Besides the traction sheave there is a deflector sheave that moves the counterweight ropes away from the car, and a 2:1 lift also has sheaves on the car top and on top of the counterweight.
Hoist ropes and 1:1 or 2:1 roping
Passenger lifts use several parallel steel ropes (standards require at least 2 independent ropes; passenger lifts typically have 4 to 8), commonly about 8 to 13 mm in diameter; some MRL lifts use thinner ropes or coated steel belts. The sheave diameter must be many times the rope diameter (in the EN 81 family of standards, at least about 40 times) so the ropes do not suffer bending fatigue.
With 1:1 roping the ropes are attached straight to the car: the car moves exactly as far as the ropes. With 2:1 roping the ropes loop under a sheave on the car and are anchored at the top of the shaft: the car travels half the rope distance and each rope carries half the load. The machine can therefore be smaller, but it must turn twice as fast.
Counterweight and guide rails
The counterweight and rails rarely fail, but a small installation error leaves a lift that vibrates and squeaks for life.
Counterweight frame and filler weights
The counterweight is an upright steel frame filled with weights made of cast iron, steel or steel-cased concrete, held by a clamp bar so they cannot shift. Figure 3 shows 25 kg weights removed during a lift renovation in an apartment block. Adding stone cladding or mirrors to the car means the balance must be recalculated and weights added.
Photo: Garsd / Wikimedia Commons, CC BY-SA 3.0
Car rails, counterweight rails and guide shoes
Guide rails are T-section steel bars fixed to the shaft wall or a steel frame with brackets spaced according to the design. The car has its own pair of rails and the counterweight has another pair, usually smaller. Guide shoes on the car and counterweight wrap around the rails: sliding shoes have plastic liners and need oil; roller guides have three rubber-tyred rollers running on dry rails and are smoother at high speed.
Why rails must be straight and clean
A misaligned rail joint makes the car shake at that exact floor; dry rails (with sliding shoes) make the lift squeal. The rails are also where the safety gear grips, so rails that are painted over or heavily soiled must be reported to the team leader.
The anti-fall chain: overspeed governor, safety gear and buffers
The machine brake holds the car when it is stationary; when the car overspeeds for any reason, this chain of three parts stops it.
Overspeed governor
The overspeed governor is a small sheave in the machine room or at the top of the shaft, with its own rope running down to a weighted tension pulley in the pit. This rope is connected to the safety gear lever on the car, so it moves at car speed (Figure 4). When speed exceeds the setting, a centrifugal mechanism in the governor acts in two stages: first it opens an electrical switch to break the safety circuit and apply the machine brake; if the car keeps accelerating, it grips the governor rope. The tripping speed is usually from about 115% of rated speed upwards; the exact figure is on the governor's data plate and in the lift documentation.
Photo: ООО ТД "Век" / Wikimedia Commons, CC BY-SA 4.0
Safety gear
The safety gear (Vietnamese technicians often call it the "parachute brake") is mounted on the lower or upper car frame and straddles the rails (Figure 5). When the governor rope is gripped while the car is still moving down, the rope pulls the actuating lever, wedges or rollers in the safety gear are forced against the rail face and the car stops on the rails. There are two main types: instantaneous safety gear stops almost immediately and is only used on slow lifts (roughly below 0.63 m/s); progressive safety gear slides a controlled distance before stopping, used on faster lifts so passengers are not jolted. Once the safety gear has acted, only an assigned person may release it, following the manufacturer's procedure.
Photo: JeanBa / Wikimedia Commons, CC BY-SA 3.0
Buffers in the pit
Buffers sit in the pit under both the car and the counterweight and catch them if they overtravel (Figure 6). Slow lifts usually have energy-accumulation buffers: springs or polyurethane blocks. Faster lifts (typically above 1 m/s) have oil buffers: a piston forces oil through an orifice to dissipate energy, then a spring pushes the piston back.
Photo: Timeamao / Wikimedia Commons, CC BY-SA 3.0
Final limit switches
Before the buffers there are final limit switches at both ends of the shaft: if the lift runs past the top or bottom floor, the switch breaks the safety circuit and the brake closes.
⚠ Safety warning: This lesson teaches recognition, not operation. Only look at ropes, sheaves, the governor or the safety gear when the lift is locked out (LOTO) and a lead technician is with you. Never touch moving ropes or sheaves; never trip the governor or safety gear "to see what happens"; never stand under the car or counterweight before the lift is locked out. Testing the safety gear and buffers is the job of assigned staff following the manufacturer's procedure.
Machine-room and machine-room-less (MRL) elevators
The traction principle is the same, but the layout changes both maintenance and rescue.
Machine-room elevators
The machine room is usually directly above the shaft, with its own locked door, ventilation and a lifting hook in the ceiling. It holds the traction machine, overspeed governor, controller and the lift's main switch. The ropes go down into the shaft through holes in the floor. Everything sits on a flat floor, so it is easy to reach and easy to release the brake during a rescue.
Machine-room-less elevators
An MRL lift mounts a gearless machine on the rails or on a beam at the top of the shaft, and the overspeed governor is also in the shaft. The controller sits in the top landing door frame or a cabinet beside the shaft, together with a remote brake release for rescue. MRL lifts save space and suit townhouses; in exchange, most machine checks have to be done from the car top.
Five quick signs
| Sign | Machine-room elevator | MRL elevator |
|---|---|---|
| Room on the roof directly above the shaft | Yes, with its own locked door and "Lift machine room" sign | No |
| Controller location | In the machine room | Top landing door frame or cabinet beside the shaft |
| Machine location | On the machine room floor | Top of the shaft, on the rails or a beam |
| Rescue brake release | Lever or button directly at the machine | Remote mechanism (cable, or electric button with backup power) |
| Usual machine type | Geared (older lifts) or gearless | Almost always gearless |
Passenger, home and freight lifts
All three can use the same traction principle but differ in load, speed, car size and typical faults. The table shows common ranges in Vietnam for reference only; always read the real figures on the data plate and in the lift documentation.
| Criterion | Passenger lift | Home lift | Freight lift |
|---|---|---|---|
| Common rated load | 450 to 1,600 kg (6 to 21 persons) | 200 to 450 kg (2 to 6 persons) | 1,000 to 5,000 kg |
| Common speed | 1.0 to 2.5 m/s; large towers can be faster | 0.3 to 1.0 m/s | 0.25 to 1.0 m/s |
| Common drive | Traction, with or without machine room | MRL traction, hydraulic, screw drive | Traction; hydraulic for very heavy loads and short travel |
| Maintenance focus | Heavy use: rope, door and call button wear | Little use: dry rails, damp, owners tampering | Impact when loading, overloading, dented rails and doors |
Passenger lifts
Passenger lifts in apartment blocks and offices make hundreds of trips a day, so ropes, sheaves, doors and call buttons wear fastest. The maximum number of persons is based on about 75 kg per person: a 630 kg lift is rated for 8 persons, a 1,000 kg lift for 13.
Home lifts
Home lifts in Vietnamese townhouses usually have a small shaft, a shallow pit, 3 to 6 stops and low speed. Besides MRL traction lifts there are hydraulic lifts (a piston pushes the car, with the pump beside the shaft) and screw-driven lifts. They run little and often sit in damp houses, so rails dry out and contacts rust; when you take over maintenance, ask whether the owner has reset the controller or opened the cabinet.
Freight lifts
Freight lifts have a heavy-duty car and frame, a non-slip floor and wide doors. Most damage comes from overloading and trolleys hitting doors and walls. A freight lift is usually not allowed to carry people unless it was designed for that; the intended use is on the data plate and in the documentation, and you must not change it.
Worked example: reading the construction of a 9-storey office lift
You join a maintenance team at a 9-storey office building. The data plate says: 750 kg load, 1.0 m/s speed, MRL, gearless machine, 2:1 roping, 400 mm traction sheave, 5 ropes of 8 mm diameter. The team leader asks you to fill in an identification sheet before entering the shaft.
Step 1: persons and lift type
- Maximum persons: 750 kg ÷ 75 kg = 10 persons. Check it against the plate in the car.
- No room on the roof, controller next to the 9th floor landing door: consistent with an MRL lift.
Step 2: rope speed and sheave revolutions
- 2:1 roping, so rope speed at the sheave = 1.0 × 2 = 2.0 m/s.
- Sheave circumference = 3.14 × 0.4 m ≈ 1.256 m.
- Sheave speed at full speed = 2.0 ÷ 1.256 × 60 ≈ 95.5 rpm.
- Sheave-to-rope diameter ratio = 400 ÷ 8 = 50, above the minimum of about 40.
Step 3: governor threshold and counterweight
- Reference minimum governor tripping speed = 1.0 × 115% = 1.15 m/s; the team leader compares it with the governor data plate.
- The documentation gives an empty car of 800 kg and a 45% balance factor: counterweight = 800 + 0.45 × 750 = 800 + 337.5 = 1,137.5 kg.
- The counterweight frame weighs 200 kg and the filler weights are 25 kg each: filler = 1,137.5 − 200 = 937.5 kg, so 937.5 ÷ 25 = 37.5, rounded up to 38 weights (actual total 200 + 38 × 25 = 1,150 kg; the balance is fine-tuned during the load test).
The identification sheet looks like the table below. If any line does not match, report it to the team leader instead of drawing your own conclusion.
| Part | Location | Data read | Result |
|---|---|---|---|
| Traction machine | Top of shaft | Gearless, 400 mm sheave | Matches documents |
| Hoist ropes | Shaft, 2:1 roping | 5 ropes × 8 mm, D/d ratio = 50 | Matches |
| Overspeed governor | Top of shaft | Rated speed 1.0 m/s, threshold ≥ 1.15 m/s | Check data plate |
| Counterweight | Shaft, own rails | 200 kg frame + 38 × 25 kg = 1,150 kg | Matches |
| Buffers | Pit | Oil buffers for car and counterweight | Check oil level |
Common beginner mistakes when identifying parts
Confusing the machine brake with the safety gear
Sign: hearing "the lift braked" and thinking of the machine brake. Cause: both are called brakes. Fix: remember the machine brake is at the machine and holds the car at rest; the safety gear is on the car and grips the rails on overspeed. If the car stopped on its safety gear, call the team leader; do not just reset the controller.
Ignoring a change in car weight
Sign: the owner has just clad the car in stone, and now the lift stops off-level and the motor runs hot. Cause: the car is heavier but the counterweight was not adjusted. Fix: write it in the log and ask the team leader to recalculate the balance.
Frequently asked questions
What are the main components of an elevator?
A traction elevator has a traction machine with brake, traction sheave, hoist ropes, car, counterweight, guide rails, overspeed governor, safety gear, buffers, controller, landing doors and car doors.
Is a machine-room-less elevator as safe as a machine-room elevator?
Both must meet the same safety requirements and must be inspected before use. The difference is the layout: MRL lifts put the equipment in the shaft, so maintenance and rescue follow the manufacturer's specific procedure.
How does an elevator overspeed governor work?
It turns at car speed through its own rope. Above the threshold it first breaks the safety circuit to stop the machine; if the car keeps accelerating, it grips the rope, which makes the safety gear clamp onto the rails.
Will an elevator fall if a rope breaks?
Lifts have several ropes, so all of them breaking at once is very rare. If the car goes down too fast for any reason, the overspeed governor and safety gear stop it on the rails, and the buffers are the last layer of protection in the pit. This only holds if these parts are maintained and inspected on time.
Practice exercise and self-assessment
- With a lead technician, standing in a safe position, fill in an identification sheet for a real lift using the table in the example: all 8 main parts, their location and the data you can read.
- Decide whether that lift has a machine room or is MRL using at least 3 signs from the comparison table.
- From the data plate, work out maximum persons, rope speed, sheave revolutions and the reference minimum governor threshold.
- Sketch the anti-fall chain by hand: governor, governor rope, tension pulley, safety gear, rails, buffers.
Self-assessment criteria
- Pass: all 8 parts located correctly, without confusing the machine brake and the safety gear.
- Pass: calculations state the roping and the sums and products match the data plate.
- Pass: the anti-fall sketch shows the right order: break the circuit first, then grip the rope, then the safety gear clamps the rails.
- Not yet: roping ignored in the calculation, lift type not identified, or any moving part touched before LOTO.
With the mechanical construction understood, move on to the next step of the roadmap: Control circuits, VFDs & safety chain, where you see how the governor switch, final limit switches and buffer switches are wired into the series safety circuit. If you have not done step 1 yet, read elevator technician safety: lockout, hoistway and car-top work before going onto a car top to look at an MRL machine.
Keep learning elevator work: after construction come control circuits and drives, landing and car doors, checklist maintenance, rescue and fault codes. See the 8-step elevator technician roadmap.