A system aluminium profile differs from a basic profile because it is designed as a matched set: thicker walls (typically about 1.2–2.0 mm against 0.7–1.1 mm), standard grooves for hardware, and gaskets and glazing pockets made for each door or window type, so the finished unit is stiffer, better sealed and can take insulated glass or a multi-point lock. Choosing materials correctly means choosing three things together: a profile system that suits the size and position of the opening, a safety glass that suits where it is fitted (tempered, laminated or insulated), and hardware, gaskets and sealant that can carry the load and survive the weather. This lesson teaches you to look at a profile, a glass panel or a box of hardware and know where it belongs.
By the end of this lesson, you will be able to:
- Tell system profiles from basic profiles by eye, with a vernier caliper and with a scale, and explain why wall thickness matters.
- Tell annealed, tempered, laminated safety and insulated glass apart, and read codes such as 6.38 or 5-9-5.
- Choose a glass type by position: doors, upper-floor windows, low-level panels and overhead glazing.
- Recognise friction stays, 3D hinges, multi-point locks, EPDM gaskets and neutral-cure silicone, and know what each is for.
- Build a materials list for a two-sash window, with profile length, glass weight, metres of gasket and tubes of sealant that add up.
Learning aluminium and glass work properly? Profile systems, glass types and hardware are step 2 of the roadmap, right after safety and before measuring, fabrication and installation. See the 8-step aluminium and glass installer roadmap to learn in the right order.
How system profiles differ from basic profiles
In Vietnamese workshops, "nhom thuong" (basic aluminium) means general-purpose extruded profiles: thin bars bought one by one and combined with hardware and gaskets from different suppliers. "Nhom he" (system aluminium) means profiles designed by one manufacturer as a complete set for each door or window type, with a catalogue of bars, gaskets, hardware and fabrication instructions.
Basic profiles: loose bars, thin walls
Basic profiles have thin walls, simple sections and few internal stiffening webs. They are cheap, light and easy to cut, and suit small windows, indoor partitions, cabinets and storeroom doors. Their weaknesses: large sashes sag, crimped corners are weaker, glazing grooves only take thin single glass, and non-standard gaskets and hardware tend to let in wind-driven rain.
System profiles: bars, gaskets and hardware as one set
System profiles have thicker walls, several chambers and stiffening webs, and hardware grooves of standard size, so hinges, locks and espagnolette bars fit properly. Each system has its own gaskets that click into their grooves, drainage slots, and a glazing pocket wide enough for insulated glass. Many Vietnamese workshops name systems by frame depth, for example "55 series" for casements and "93 series" for sliders; these names come from some popular product lines and each brand differs, so always use the catalogue for the exact brand. Some premium systems add a plastic thermal break between the inner and outer halves of the profile to cut heat transfer.
Photo: HTL-Mödchen23 / Wikimedia Commons, CC BY-SA 4.0
Figure 1 shows the first thing to train your eye on: cut across a profile and you see wall thickness, chambers and gasket grooves. When collecting stock, ask for an offcut or look at the bar ends before you sign for it.
Quick comparison
| Point | Basic profile | System profile |
|---|---|---|
| Wall thickness (typical, for reference) | About 0.7–1.1 mm | About 1.2–2.0 mm depending on system and bar |
| Section | Simple, few chambers | Several chambers, stiffening webs, drainage |
| Hardware | Bought separately, no standard groove | Standard grooves for hinges and multi-point locks |
| Gaskets | Generic, prone to gaps | Matched to each groove, usually EPDM |
| Glass it takes | Mostly thin single glass | Thick single, laminated or insulated glass |
| Suits | Small windows, indoor partitions, cabinets | Front doors, large doors, upper-floor windows, noisy streets |
| Cost | Lower | Clearly higher, depending on brand and colour |
Profile wall thickness and how to check it on delivery
Wall thickness decides whether a sash is stiff, whether crimped corners hold and whether hardware screws keep their grip. A large door sash made from thin profile will sag within months, so an installer must check thickness rather than take the supplier's word for it.
How thick is enough
There is no single number for every door. As a market rule of thumb (always confirm in the brand catalogue), system window bars are often about 1.2–1.4 mm and door bars about 1.4–2.0 mm, with large sliders and shopfront doors at the thicker end. The bigger the sash, the heavier the glass and the higher the floor, the thicker the profile you need. Each system's catalogue gives the maximum sash size; beyond that, add a mullion or transom or choose a heavier system.
Measure with a caliper in the right place
- Take a freshly cut bar end and clean off chips and burrs.
- Measure the main flat wall with a vernier caliper, not ribs, fins or groove lips.
- Measure at least 3 points at both ends of the bar and record the smallest value.
- The reading includes the powder coat (roughly 0.05–0.1 mm). A bar sold as "1.4 mm" that reads 1.2 mm including paint is under thickness.
Weigh a sample
Aluminium has a density of about 2.7 g/cm³. A profile with 3.7 cm² of metal in its section weighs about 3.7 × 100 × 2.7 = 999 g per metre, roughly 1 kg/m. System catalogues usually list kg/m for each bar code. Quick check: weigh a 0.5 m piece, multiply by 2 and compare with the catalogue; clearly lighter means thinner walls than advertised.
Surface finishes
Window and door aluminium is usually a 6xxx-series alloy (6063 is common), extruded and then finished: powder coating (many colours, the most common), anodising (a hard oxide layer with a metallic look) or wood-grain transfer. On delivery, look along the bar under a light: even colour, no pits, no scratches, and the protective film intact until installation is finished.
Tempered, laminated safety and insulated glass
In the safety lesson you learned that glass weighs about 2.5 kg per m² for each millimetre of thickness (see Glass installation safety: suction lifters, cut gloves, saws). This step is about how each glass type breaks, because the way it breaks decides where it may be fitted.
Annealed (float) glass and why it is not used in doors
Annealed glass is flat glass with no heat treatment: it can be cut and drilled and is cheap, but it breaks into large knife-like shards. It suits cabinets and small panes high up; doors, low-level panels, shower enclosures and balustrades must not use it.
Tempered glass
Tempered (toughened) glass is annealed glass that has been cut, drilled and edged, then heated to roughly 600–700 °C and cooled quickly with air jets. It resists impact and bending about 4–5 times better than annealed glass of the same thickness, and breaks into small granules that rarely cause deep cuts. After tempering it cannot be cut, drilled or ground (the whole panel shatters), so every hole and notch must be ordered in advance; it can also break spontaneously because of inclusions or chipped edges. On delivery, look for the manufacturer's stamp or etched mark in a corner.
Laminated safety glass
Laminated glass is two or more glass layers bonded with a plastic interlayer, usually PVB 0.38 mm or 0.76 mm thick. The code 6.38 means two 3 mm layers plus a 0.38 mm film; 8.38 is 4 + 4 + 0.38. When it breaks, the fragments stay stuck to the film, so the panel still closes the opening and nothing falls on people below (see Figure 2). That is why laminated glass is preferred for upper-floor windows, overhead glazing, balustrades and facades over walkways. Laminated glass made from annealed layers can still be cut by a glass shop with the right technique; laminated glass made from tempered layers must be ordered to size.
Photo: Ali azid / Wikimedia Commons, CC BY-SA 3.0
Insulated glass units
An insulated glass unit (IGU, "kinh hop" in Vietnamese) is two or three panes held apart by a hollow spacer bar around the edge; the spacer contains desiccant beads and the outer edge is sealed with two layers of sealant to keep the cavity dry and airtight (Figure 3). The code 5-9-5 means 5 mm glass, a 9 mm cavity and 5 mm glass, 19 mm in total. The cavity improves sound and heat insulation compared with single glass, but only if the frame and gaskets are tight; each pane can itself be tempered or laminated. An IGU needs a wide enough glazing pocket, so it usually goes only into system profiles. A failed unit shows condensation or haze inside the cavity that cannot be wiped off.
Photo: HTL-Mödchen23 / Wikimedia Commons, CC BY-SA 4.0
Choosing glass by position
| Glass type | When it breaks | Cut or drill afterwards | Suits |
|---|---|---|---|
| Annealed | Large sharp shards | Yes | Cabinets, small high panes where nobody can hit them |
| Tempered | Small granules | No, order to size | Doors, partitions, showers, low-floor windows |
| Laminated safety | Cracks but stays on the film | Yes if made from annealed glass, at a glass shop | Upper-floor windows, overhead glazing, balustrades, street facades |
| Insulated unit | Depends on the panes inside | No, order to size | Noisy streets, air-conditioned rooms, sunny elevations |
These are trade rules for first advice. On designed projects, glass type and thickness follow the drawings and the current technical standards; if unsure, ask the design engineer or glass supplier, and never downgrade the glass on your own.
Hardware: hinges, multi-point locks and small parts
Hardware is the moving part of a door or window and the most common reason for warranty calls. It must match the profile system (the right groove), the opening direction and the sash weight.
Hinges
- Friction stays: for top-hung or outward-opening casement windows, holding the sash open by friction. Choose by sash size and the weight rating on the pack.
- 3D hinges: for doors and casements, adjustable in three directions (up and down, side to side, compression) to set the sash after installation.
- Barrel hinges: cylindrical hinges widely used on aluminium doors, with good load capacity.
- Floor springs and patch fittings: for frameless tempered glass doors, covered in the glass partitions and floor-spring doors step.
General rule: the number and type of hinges follow the sash weight, and the rating on the pack should exceed that weight with a margin, never just match it.
Multi-point locks
A multi-point lock has a drive bar running inside a groove along the sash edge. Turning the handle slides the bar and pushes several bolts (often mushroom-head cams) into keepers on the frame, so the sash is pressed onto the gasket at several points at once. The result is a tighter seal, better resistance to forcing and less bowing on tall sashes. Multi-point locks need the standard hardware groove of a system profile.
Sliding door hardware and small parts
Sliding doors need rollers rated for the sash weight, tracks, a crescent lock or a sliding multi-point lock, and brush seals in the sliding gaps. Add corner cleats for crimping, flush bolts, handles and drain-hole caps: cheap parts, but missing one means a leaking or non-closing door, so put them all on the materials list from the start.
Gaskets and silicone sealant
A good system door with cheap gaskets or the wrong sealant will still leak after one rainy season.
EPDM gaskets and cheap plastic gaskets
Gaskets sit in three main places: glazing gaskets (pressing the glass from both sides), sash gaskets (where the sash closes on the frame) and brush seals on sliders. EPDM is a synthetic rubber that resists sun and stays elastic for years; cheap plastic gaskets look similar but harden, shrink at corners and crack after a few years. Test: press with a fingernail and a good gasket springs straight back; fold it and it does not turn white at the fold.
Neutral-cure and acetic silicone
Acetic silicone (vinegar smell when applied) cures fast and is cheap, but its acid vapour can damage powder-coated or anodised aluminium, the silver backing of mirrors and some stone. For aluminium and glass work, use neutral-cure silicone (no vinegar smell) labelled for glass, aluminium or weather sealing. Structural silicone (bonding load-bearing glass to a frame) is a separate product used only with a design and the maker's instructions. Silicone skins over within tens of minutes but takes much longer to cure through; the cure rate is printed on the tube.
Which sealant for which gap
- Glass to aluminium: gaskets do the main job, neutral silicone only assists; never replace gaskets with silicone around the whole pane.
- Frame to wall: fill wide gaps with foam and seal both faces with weatherproof neutral silicone (Figure 4); this is covered in detail in the installation step.
- Silicone cannot be painted over; if the wall will be repainted, agree this with the client first.
Photo: MTA Capital Construction Mega Projects / Wikimedia Commons, CC BY 2.0
⚠ Safety with glass, aluminium and sealants: never drill, cut or grind tempered glass or insulated units on site; the panel will shatter. Always handle glass with cut-resistant gloves, safety glasses and enough people for the panel weight. Apply silicone in a ventilated area; if sealant gets in your eyes, rinse with plenty of clean water and see a doctor. Foam and many solvents are flammable, so keep them away from flames. Never fit annealed glass where safety glass is required.
Worked example: materials for a 1,200 × 1,400 mm two-sash window
Situation: a four-storey townhouse on a busy street; the owner wants to replace a third-floor bedroom window. The opening is 1,200 × 1,400 mm (width × height), two outward-opening casement sashes, and the owner wants less noise and no risk of glass falling onto the street. The sizes below are rounded for practising material choice; exact measuring and fitting gaps belong to the next step.
Step 1: choose the profile system and glass
- Profile: a casement window system with bars of about 1.4 mm, because the third floor takes wind load and needs a wide glazing pocket.
- Glass: a 5-9-5 insulated unit to cut noise; since it is high up and faces the street, ask the supplier for an option with a laminated or tempered outer pane. Weight is calculated with two 5 mm panes.
- Hardware: system friction stays, a multi-point lock with turn handle, EPDM gaskets for the system, weatherproof neutral silicone.
Step 2: profile length and glass weight
- Outer frame: 2 × (1.2 + 1.4) = 5.2 m.
- Centre mullion: about 1.3 m.
- Sashes: each about 0.58 × 1.33 m, perimeter 2 × (0.58 + 1.33) = 3.82 m; two sashes = 7.64 m.
- Glazing beads: each pane about 0.48 × 1.23 m, perimeter 2 × (0.48 + 1.23) = 3.42 m; two panes = 6.84 m.
- Total profile: 5.2 + 1.3 + 7.64 + 6.84 = 20.98 m, before cutting waste (optimising waste is part of the cutting list step).
- Glass area: 0.48 × 1.23 = 0.59 m² per pane (rounded); two panes = 1.18 m².
- Weight of the 5-9-5 unit: 10 mm of glass × 2.5 = 25 kg/m²; 1.18 × 25 = 29.5 kg, about 14.75 kg per pane.
- Weight of one sash: glass 14.75 kg + sash profile 3.82 m × about 1 kg/m = 3.82 kg + hardware about 1 kg = about 19.6 kg. The friction stays must be rated above this with a margin.
Step 3: gaskets, sealant and summary
Glazing gaskets on both faces: 6.84 × 2 = 13.68 m; sash gaskets 7.64 m; together 21.32 m, plus 10% for corners: 23.45 m, so order 24 m. Silicone along the frame-to-wall joint, both faces: 5.2 × 2 = 10.4 m. A 6 × 6 mm bead uses 36 mm² × 1,000 mm = 36,000 mm³, or 36 ml per metre; a 300 ml tube covers about 300 ÷ 36 = 8.3 m. You need 10.4 ÷ 8.3 = 1.25 tubes, so take 2.
| Item | Calculation | Quantity |
|---|---|---|
| Outer frame + mullion | 5.2 + 1.3 | 6.5 m |
| Sash profile | 3.82 × 2 | 7.64 m |
| Glazing beads | 3.42 × 2 | 6.84 m |
| Total profile (before waste) | 6.5 + 7.64 + 6.84 | 20.98 m |
| Insulated glass 5-9-5 | 2 panes × 0.59 m² | 1.18 m², about 29.5 kg |
| EPDM gasket | (13.68 + 7.64) × 1.1 | 23.45 m, order 24 m |
| Neutral silicone, 300 ml | 10.4 m ÷ 8.3 m per tube | 2 tubes |
| Hardware | Per system | 2 pairs of friction stays, 2 multi-point lock sets with handles (one per sash, because of the mullion), drain caps |
Cross-check: 6.5 + 7.64 + 6.84 = 20.98 m, matching Step 2. If the client switches to single 8 mm tempered glass, the glass weighs 1.18 × 20 = 23.6 kg, but the sound insulation of the cavity is lost.
Common material mistakes and how to avoid them
Thin profile on a large door
Sign: the sash sags, scrapes the floor and the lock becomes hard to engage within months. Cause: thin profile chosen to save money. Fix: choose the system by the maximum sash size in the catalogue, add a mullion if needed and measure thickness on delivery.
Ordering tempered glass before thinking about holes
Sign: the glass arrives on site without hinge or handle holes. Cause: holes were not marked on the glass order. Fix: mark every hole and notch on the order drawing; once tempered, order a new panel instead of drilling on site.
Insulated glass in a frame without enough pocket
Sign: gaskets have to be left out or beads forced in; after the rainy season the unit fogs inside. Cause: the glazing pocket is too narrow for glass plus gaskets. Fix: check the glazing pocket in the catalogue before ordering glass.
Frequently asked questions
Which is better, system or basic aluminium?
System profiles are stiffer, seal better and take insulated glass and multi-point locks, so they suit front doors and large openings. Basic profiles are cheaper and fine for small windows and indoor partitions. Better means right for the job, not the most expensive.
What wall thickness is standard for system aluminium?
Typically about 1.2–1.4 mm for windows and 1.4–2.0 mm for doors (for reference, depending on brand and system). The correct figure is in the brand catalogue for each bar code; use a caliper and a scale to check.
What is 6.38 laminated safety glass?
Two 3 mm glass layers bonded with a 0.38 mm PVB film, about 6.38 mm in total. When it breaks, the fragments stay on the film and do not fall, which suits upper-floor windows, overhead glazing and balustrades.
How do I tell neutral-cure silicone from acetic silicone?
Read the label (it usually says neutral or acetic, and whether it is for glass and aluminium); when applied, acetic silicone smells strongly of vinegar. Use neutral-cure on coated or anodised aluminium, mirrors and stone.
Practice tasks and self-assessment
- In the workshop, take 3 different profiles (one basic, two system bars), measure wall thickness at 3 points on each, weigh a 0.5 m piece, record kg/m and compare with the catalogue.
- Inspect 4 glass panels in stock: identify the tempered one (corner mark), the laminated one (film visible at the edge) and the insulated unit (spacer bar), and read their thickness codes.
- Open a hardware box for a window system and name the hinges, drive bar, mushroom cams, keepers, glazing gaskets and sash gaskets.
- Redo the worked example for a 1,000 × 1,200 mm two-sash window, with a materials table that adds up.
Self-assessment criteria
- Pass: thickness measured in the right place, repeat readings within 0.05 mm, and kg/m close to the catalogue.
- Pass: all 4 glass panels named correctly, with where each one goes and why.
- Pass: the materials table gives total profile, glass weight, gasket metres and sealant tubes that add up, and hinges rated above the sash weight.
- Not yet: measuring on ribs or fins, confusing laminated with tempered glass, choosing acetic silicone for coated aluminium, or totals that do not add up.
To see how these glass types and fittings come together in a finished product, read Installing a glass shower enclosure: sizes, 8 or 10 mm, no leaks. Once you know your materials, move on to the next step of the roadmap: Measuring openings & cutting lists, where you measure openings at three points, check squareness, deduct fitting gaps, plan sash layouts and build cutting lists that reduce profile waste.
Keep learning aluminium and glass work: after profile systems, glass and hardware come measuring, cutting and assembling frames, installing doors and windows, tempered glass partitions, shower enclosures and per-m² quoting. See the 8-step aluminium and glass installer roadmap.