A customer calls: “This is the fourth bulb I've put in the hallway light this year, all brand-new LED bulbs, and every few months it just goes dead.” Another is annoyed because the newly installed bathroom ceiling light has already started flickering. In some homes, after a thunderstorm, several bulbs in different rooms fail at the same time.
Customers usually think “the bulbs are rubbish”. Sometimes that is true, but if good bulbs keep failing in the same position, the cause usually lies in the power supply, the lampholder, the temperature around the bulb, the control device or moisture. The electrician's job is to find that cause, not just to change the bulb and leave.
This lesson guides you through diagnosis in the order of a typical call-out: questioning the customer and reading the failure pattern, measuring voltage, checking the lampholder and connections, checking heat, checking switches, dimmers and sensors, checking for moisture, then choosing a replacement bulb and advising the customer. By the end of this lesson, you will be able to work through these checks systematically and fix the root cause so the lights last. The scope is screw-base LED bulbs (E27, E14), round LED bulbs, ceiling-mounted lights and recessed downlights on a single-phase 220 V household supply. The lesson does not cover repairing the circuitry inside the bulb.
Safety first: only remove bulbs, open lampholders or remove switch plates after switching off the lighting circuit breaker, hanging a sign and verifying that it is dead according to the 5 mandatory safety rules. Do not assume that turning off the switch is enough: in many homes the switch is wired into the neutral and the lampholder is still live. Use a sturdy ladder, have someone hold it when working at height, and wait for the bulb to cool before removing it. The figures in this lesson (voltage ranges, temperatures, lifetimes) are reference values; always check the ratings printed on the bulb, the manufacturer's instructions and the applicable standards.
Why LED bulbs fail: understand the construction before diagnosing
A household LED bulb has two main parts:
The LED board: many small LED chips, usually connected in series in one or a few strings. If a single chip fails open, the whole string goes out, so the bulb can be completely dead even though the other chips are fine.
The power supply (driver): a small circuit inside the bulb body that converts 220 V AC into a DC current suitable for the LED chips. The driver contains electrolytic capacitors, diodes, an IC and inductors. It is the part least tolerant of heat and voltage surges and also the part that fails most often.

Cheap LED bulbs often use a capacitive-dropper power supply: few components, no isolation, and very sensitive to high voltage and surges. Better bulbs usually use a switch-mode supply with a current-control IC, which tolerates a wider voltage range. They are hard to tell apart from the outside, so you need to rely on the ratings printed on the bulb, its origin and the warranty.

The biggest enemy of LED bulbs is heat. Both LED chips and electrolytic capacitors age faster when hot. A rule of thumb often quoted in electronics is that an electrolytic capacitor running about 10 °C hotter may have its lifetime cut roughly in half (for reference, depending on the type of capacitor). So the same bulb placed in a sealed shade or under a hot metal roof will last much less than one installed in an open, ventilated spot.
Common failure patterns:
Completely dead: usually an open LED chip or a failed driver.
Flickering, constant blinking: a driver about to fail, poor contact in the lampholder, an incompatible dimmer, or leakage current through the switch.
Gradually dimming, with a dark patch: LED chips aged by heat, or a few chips shorted.
Lights up, goes out after a few minutes, comes back on when cool: a sign of overheating or a driver component that fails when hot.
The lifetime printed on the box is declared by the manufacturer under its own test conditions; in a real home, heat, voltage and the way the bulb is installed can make the lifetime much shorter.
Step 1: Question the customer and read the failure pattern
Before climbing the ladder, spend five minutes talking. The answers often narrow down half of the possible causes:
Is it failing in one position or all over the house? Repeated failure in one position points to the lampholder, the shade, the switch or moisture at that spot. Failures in several positions and rooms point to the supply voltage, lightning surges or a bad batch of bulbs.
How long do the bulbs last before failing? A few days to a few weeks: suspect a faulty bulb, the wrong type (a standard bulb on a dimmer) or excessive voltage. A few months: suspect heat, moisture or poor contact.
Did it fail after a particular event? After a thunderstorm, after a power cut when the power came back, after the utility worked on the line, after the house installed a large new appliance.
What controls the light? A standard switch, a switch with an indicator light, a touch switch, a smart switch, a dimmer, a motion sensor or a timer switch.
Does the light flicker or glow dimly when switched off? If so, also see the lesson on LED lights glowing dimly or flickering after being switched off.
Do you still have the old bulbs? Ask to see the failed bulbs: the rating label, black burn marks on the base, and yellowed or heat-deformed plastic on the bulb body.
Step 2: Measure the supply voltage at different times
Prepare a multimeter with a suitable measurement safety category (for example CAT III, for reference), probes in good condition and probe tips with protective caps. For how to use the meter, see the lesson on using a multimeter as an electrician.
The safest and easiest way is to measure at a socket on the same circuit or near the light, rather than poking probes into a live lampholder:
Set the meter to the AC voltage range (V~), on a range above 250 V.
Measure between the two holes of the socket (line–neutral). Record the reading and the time.
If the house has an earth conductor, also measure between neutral and earth (N–PE).
Measure again at the evening peak and late at night or early in the morning, because the voltage can differ considerably between heavy-load and light-load periods on the grid.
Switch on a large load in the house (water heater, induction hob) and see how much the voltage changes.
Remember that a multimeter only shows the voltage at the moment of measurement. Short surges from lightning or switching large loads last a very short time, and the meter will not catch them. If you suspect erratic voltage fluctuations, you can plug a voltage monitor that records maximum and minimum values into a socket for a day or two.
Reference table for interpreting voltage readings
Reading (for reference) | Interpretation | What to do |
|---|---|---|
Around 220 V, little variation between readings | Stable supply; voltage is unlikely to be the main cause | Move on to checking the lampholder, heat and switches |
Regularly much higher late at night, for example above about 240 V | High voltage when the grid is lightly loaded; cheap bulbs with a narrow voltage range fail easily | Record readings and times; the customer can report to the utility; choose bulbs rated for a wide voltage range |
Regularly much lower at peak times, for example below about 200 V | Weak supply; lights may be dim or blink; other appliances are also affected | See the lesson on installing a voltage stabiliser for the home; report to the utility if it persists |
Voltage drops sharply when a large load in the house is switched on | A poor contact or undersized cable on the supply path, possibly at the main breaker, a terminal block or the cable after the meter | Switch off, check and retighten the connection points; measure again |
N–PE abnormally high (several volts) | Possibly a poor neutral connection or a problem with the earthing | Check neutral connections in the distribution board and junction boxes; check the earthing system |
Abnormal voltage surge, with many neighbouring homes also losing appliances | Possibly a fault on the grid side (for example a broken shared neutral on the low-voltage line) | Switch off the main breaker and report to the utility immediately; do not interfere with anything upstream of the meter |
The thresholds in the table are only a guide, not regulatory limits. When advising the customer, give the actual readings and times rather than declaring “your house has overvoltage”.
If bulbs often fail after thunderstorms in several rooms, think of lightning-induced surges. In that case, advise the customer to install a surge protective device in the distribution board as described in the lesson on installing a surge protective device (SPD).
Step 3: Check the lampholder, contact tab and wire connections
With screw-base bulbs, poor lampholder contact is a very common cause when bulbs fail in only one position. Poor contact makes the contact point heat up and sometimes causes the power to cut in and out repeatedly. Heat from the lampholder goes straight into the bulb base, right below the driver.
Inspection sequence:
Switch off the lighting circuit breaker, hang a sign and verify that the lampholder is dead with a voltage tester or multimeter (having tested the instrument on a live source beforehand).
Wait for the bulb to cool and remove it. Inspect the bulb base: black marks or pitted burns on the central contact are signs of poor contact.
Look into the lampholder: is the brass tab at the bottom pushed down too far, blackened or no longer springy; is the plastic brittle, cracked or turned brown; is the metal thread rusty?
Open the shade or the lampholder cover and check whether the terminal screws are loose, the wire ends oxidised or blackened, or the insulation hardened by heat.

How to fix it:
Brass tab slightly pushed down but still clean and springy: with the power off, you can use an insulated plastic stick to lift the tab slightly for a firmer contact. This is a temporary fix; if the tab is blackened or soft, replace the lampholder.
Blackened tab, brown or brittle plastic: replace the lampholder. In hot locations (sealed shades, close to a metal roof), consider a porcelain lampholder that withstands heat better.
Oxidised wire ends, hardened insulation: cut off the damaged section and strip back to clean wire. If the wire is too short, extend it properly in a junction box as described in the lesson on how to join electrical wires properly.
When rewiring a screw lampholder, connect the line wire to the central contact (bottom tab) and the neutral to the thread. That way, when the customer screws the bulb in, the metal thread — the part most likely to be touched — is on the neutral side. Also check that the switch breaks the line conductor, not the neutral.
For ceiling-mounted lights and downlights, carry out the same checks at the terminal block: are the screws tight, are there burn marks, is any wire trapped against the metal housing?
Step 4: Check the heat around the bulb and the type of shade
If the supply is stable and the lampholder is good but bulbs still keep failing in one position, think of heat. Common situations:
Sealed shades: screw-base LED bulbs inside sealed glass shades, sealed globes or enclosed wall lights. The heat cannot escape. Some bulbs clearly state that they must not be used in enclosed fittings; if the box does not say the bulb is suitable for enclosed fittings, treat it as unsuitable.
Bulbs installed base-up: for example pendants or chandeliers with bulbs pointing downwards. Hot air rises and gathers around the bulb base, where the driver is. This is an observation from experience; the effect depends on the bulb type.
Downlights and ceiling lights under a metal roof: the ceiling void gets hot at midday, and the light may also be covered by insulation or debris in the ceiling.
High-power bulbs in small shades: the customer replaces a 9 W bulb with a 20 W bulb “to make it brighter” but keeps the same shade.

A simple check: leave the light on continuously for about 30–60 minutes (for reference), then use an infrared thermometer to measure the temperature of the bulb body or light housing and compare it with an identical light installed in a ventilated spot in the house. Do not touch a bulb that has been on for a long time with bare hands, as you can easily get burned. If you have no thermometer, remove the shade and run the light without it for a few weeks to compare its lifetime.
How to fix it:
Replace with a bulb marked suitable for enclosed fittings, or switch to a light with a heat sink and a driver designed for that location.
Reduce the bulb's wattage to suit the shade.
For downlights, clear the space above them and do not let insulation cover the light unless the manufacturer allows it.
In very hot locations, advise the customer to change the type of light (a ceiling light with an aluminium heat sink, an open fitting).
Step 5: Check switches, dimmers, sensors and smart switches
Control devices are a frequently overlooked cause.
Dimmers
LED bulbs generally cannot be used with a dimmer. Fitting a bulb not marked “dimmable” on a circuit with a dimmer easily makes it flicker, buzz and fail early. Even dimmable bulbs need a compatible dimmer. Fix: either replace the dimmer with a standard switch, or use a dimmable bulb with a suitable dimmer as recommended by the bulb manufacturer.
Switches with indicator lights, touch switches, smart switches without a neutral
These types can let a small current flow through the bulb even when switched off. The LED bulb receives this current, stores charge in its capacitor and then flashes intermittently or glows dimly. A driver forced to cycle “on–off” like this all night can fail sooner. Detailed fixes are in the lesson on LED lights glowing dimly after being switched off: change to a standard switch, use a smart switch that has a neutral connection, or fit a bypass device as instructed by the switch manufacturer.
Switches with poor contact
A switch that is loose or arcing inside gives the bulb an unstable supply every time it is switched on. Customers often say, “I have to press it two or three times before it comes on.” Check and replace the switch as described in the lesson on light switches that stick, are loose, click or spark.
Motion sensors and timer switches
Hallway and stairway lights with sensors may switch on and off dozens of times a day. LED bulbs generally tolerate switching better than compact fluorescent bulbs, but each time they are switched on, the driver takes a short inrush current. A poor-quality bulb combined with a poor sensor (a relay with intermittent contacts, or an on-time set so short that the light keeps switching on and off) can make the bulb fail quickly. Set a sensible on-time and check whether the sensor chosen is the right type for LED lights (does it state a permitted LED load?).
Step 6: Check for moisture, water and insects
Bathrooms, balconies, porches, canopies and areas near the cooker are places where bulbs often fail because of moisture. Water vapour gets into the shade, condenses on the driver circuit and corrodes component leads and lampholder contacts.
With the power off, remove the shade and look for:
Water droplets, dried water marks, white deposits or green corrosion on the lampholder or terminal block.
Dead insects or a thick layer of dust inside the shade.
Whether the light's rubber gasket still seals and whether the cable entry is sealed.
Fix: replace with a light whose ingress protection rating (IP rating) suits the location, seal the cable entry, and mount the light so water cannot run along the cable into it. How to choose the IP rating and waterproof outdoor lights is covered in the lesson on installing outdoor lighting. In bathrooms, the lighting circuit should have residual current protection (RCD/RCBO) and the light should be installed away from areas reached by direct water spray.
Step 7: Assess the bulbs in use and choose suitable replacements
Only after ruling out the supply, lampholder, heat, controls and moisture should you draw conclusions about bulb quality. When choosing a replacement bulb, read the label on the bulb or the box carefully:
Operating voltage range: for example “220–240 V” or a wider range such as “100–250 V”. Where the voltage fluctuates a lot, bulbs with a wide range usually cope better (for reference, depending on the bulb design).
Wattage and base: the correct base (E27, E14, etc.) and a wattage suited to the shade.
The dimmable mark if the circuit has a dimmer.
Whether it can be used in enclosed fittings and in damp locations.
Full product labelling: the name and address of the manufacturer or importer, ratings and a clear warranty. Unlabelled goods at unusually low prices are usually bulbs with a very basic driver.
Advise the customer to buy the same type of bulb for one area and keep the receipt and warranty card. If a bulb fails within the warranty period, it can be exchanged, and you also get more data to tell whether the fault lies with the bulb or with the installation position.
Quick reference table: symptoms, common causes and fixes
Symptom | Common cause | How to check | Fix |
|---|---|---|---|
Repeated failures in one position, other positions normal | Poor lampholder contact, hot sealed shade, moisture, the light's own switch | Inspect the bulb base and lampholder tab, measure temperature, open the shade to look for water | Replace the lampholder, use a bulb suitable for enclosed fittings, protect against moisture, replace the switch |
Several rooms fail at once after a thunderstorm | Lightning-induced surge | Ask when it failed and whether other electronic devices were damaged | Recommend an SPD for the distribution board; check the earthing |
New bulbs fail after a few days or weeks, in several positions | High voltage, bad batch of bulbs, wrong bulb type | Measure voltage at several times, read the bulb label | Report to the utility if the voltage is abnormal; change to bulbs with a suitable voltage range |
Flickering or dim glow when switched off | Switch with indicator light, touch switch, smart switch without N; switch breaking the neutral | Remove the switch and check its type and wiring | Change the switch, wire the switch into the line conductor, use a bypass device as specified by the manufacturer |
Flickering, buzzing when on | Incompatible dimmer, bulb driver about to fail | Check for a dimmer, try another bulb | Remove the dimmer or use a compatible bulb and dimmer |
Lights for a few minutes then goes out, comes back on when cool | Overheating, driver component failing when hot | Measure temperature, test the bulb in a ventilated spot | Change the position or type of light, replace the bulb |
Light blinks when the pump or water heater switches on | Poor contact on the shared supply path, undersized cable | Measure voltage when the large load is switched on | Switch off, retighten terminal blocks, breakers and joints; review the cable size |
Lampholder blackened, plastic melted | Long-term poor contact, bulb wattage too high | Switch off and remove the lampholder to inspect | Replace the lampholder, check the wiring, choose a suitable wattage |
Two real-life examples
Example 1 – A stairway light on a motion sensor, one bulb every three months. The measured voltage is stable; the bulb sits in a sealed round glass shade; the sensor's on-time is set very short, so the light keeps switching on and off as people walk past. Fix: set a longer on-time, change to a bulb marked suitable for enclosed fittings, and ask the customer to let you know if the new bulb still fails early.
Example 2 – A bathroom ceiling light flickering after two months. Opening the light reveals water inside the shade and green corrosion on the terminal block; the light has no sealing gasket, is mounted right above the shower area, and the cable entry is open. Fix: switch off, replace the terminal block, replace the light with one of a suitable IP rating, seal the cable entry, and check that the bathroom circuit has residual current protection.
Safety checklist
Switch off the lighting circuit breaker, hang a sign and verify the circuit is dead before removing bulbs, opening lampholders, shades or switches.
Test the voltage tester or multimeter on a live source before and after verifying that the circuit is dead.
Wait for bulbs and shades to cool before removing them; do not touch a bulb that has been on for a long time with bare hands.
Use a sturdy ladder on flat, dry ground, with someone holding it when working at height.
Measure voltage at a socket with capped probes; do not poke probes into a live lampholder.
Screw lampholders: line to the central contact, neutral to the thread; the switch must break the line conductor.
In bathrooms and damp locations: lights with a suitable IP rating, circuits with residual current protection, cable entries sealed.
If you see signs of a grid-side fault (voltage surges, many homes affected at once): switch off the main breaker and report to the utility; do not work on anything upstream of the meter.
Collect failed bulbs separately, do not smash them; dispose of them according to local electronic waste collection guidance.
Advising the customer after the repair
At the end of the job, tell the customer briefly: what you found (for example “the lampholder tab was burnt black; the poor contact made it hot and damaged the bulbs”), what you did (“I replaced it with a porcelain lampholder, connected the line wire to the central contact and fitted a bulb suitable for enclosed fittings”) and what to watch (keep the bulb receipt, note the replacement date, and call back if the bulb fails early). Do not open a failed bulb, bridge the dead LED chip and refit it for the customer: the bulb will run at the wrong current, get hotter and risk exposing live parts. If the cause is the grid voltage, explain clearly that it is not a fault inside the house and give the customer the table of readings you recorded so they can take it up with the utility.
Frequently asked questions
Does switching LED lights on and off a lot make them fail faster?
LED bulbs generally tolerate switching better than compact fluorescent bulbs. With normal household use, switching is not the main cause of failure. But if the light is switched very frequently (a sensor with a very short on-time, a switch with intermittent contact) and the bulb has a poor driver, it can still fail early.
Can a failed LED bulb be repaired?
Technically, some faults such as an open LED chip or a failed capacitor can be fixed. But household bulbs are inexpensive, opening a bulb can expose live parts, and a repaired bulb is hard to guarantee for safety and lifetime. An electrician working for a customer should fit a new bulb and focus on finding what is making the bulbs fail.
Should a house where bulbs often fail get a voltage stabiliser?
Only if you have measured and found the voltage to be genuinely low or fluctuating a lot over a long period. If the cause is the lampholder, heat or a switch, a stabiliser will not solve it. If the grid voltage is too high or there are lightning surges, report it to the utility and consider a surge protective device; a stabiliser is not a substitute for an SPD.
Why did a newly bought bulb fail after just a few days?
It may be a manufacturing defect, but it may also be the installation position: a circuit with a dimmer, poor lampholder contact, an overheated sealed shade or abnormal voltage. Try a bulb of the same type in another position in the house and a different type of bulb in the original position, then compare the results to tell whether the fault lies with the bulb or the location.
Is it safe to change a bulb with the switch turned off?
Not necessarily. If the switch is wired into the neutral, the lampholder is still live even when the light is off. Electricians always switch off the lighting circuit breaker and verify the circuit is dead. For customers changing bulbs themselves at home, advise them to switch off the breaker, wait for the bulb to cool, stand on something stable and hold the bulb by its plastic body.
Practice exercises
Exercise 1 – Measuring voltage by time of day: At home or at your placement, measure the socket voltage at three times of day (early morning, midday, 7–9 pm) over three days. Make a table and work out the largest difference. Also measure when a large load is switched on and record the voltage drop.
Exercise 2 – Scenario: A house has a balcony light using an E27 LED bulb inside a sealed round glass shade, controlled by a touch switch with no neutral wire. The bulb fails about once every two months, while the other lights in the house are fine.
List at least three possible causes.
Put the checks in a sensible order and explain why.
Propose a fix and how you would explain it to the customer.
Suggested answer: Suspect heat from the sealed shade, leakage current through the touch switch without N making the bulb flash when off, moisture getting into the shade on the balcony, and poor lampholder contact. First check what you can see quickly with the power off (the lampholder, water in the shade), then watch the light while it is off to see whether it flashes, and then measure the temperature after it has been on for a long time. Fix: replace the switch with a suitable one or one with a neutral connection, change the balcony light to one with a suitable IP rating and a bulb suitable for enclosed fittings, and replace the lampholder if it is burnt.
Exercise 3 – Lampholder practice: On a de-energised practice board, remove an E27 lampholder, identify the central contact and the thread, connect the line wire to the central contact and the neutral to the thread, and wire the switch into the line conductor. Ask the instructor to check it before switching on, then use a voltage tester to confirm that the central contact is dead when the switch is off.
Conclusion
LED bulbs that keep failing are rarely just “bad luck”. A good electrician reads the failure pattern, measures the voltage at different times, checks the lampholder and connections, looks at the heat around the bulb, checks the control devices and moisture, and only then chooses a suitable replacement bulb. Following that sequence, you fix the problem at its root, the customer spends less on replacement bulbs, and they will trust you with bigger jobs.