A bathroom washbasin is one of the first fixtures a trainee plumber installs alone, and one of the easiest to get slightly wrong. It looks fine on the day; weeks later it rocks when someone leans on it, a damp patch appears under the waste, or the trap smells. Almost all of these problems come from a few steps: checking the wall, choosing the right fixings, fitting the tap and waste correctly, and making a proper trap connection.
This guide follows the job in the order a careful plumber works: choosing and checking the basin, surveying the wall and the supply and drain points, setting out, fixing the basin or vanity, fitting the tap and waste, connecting the supply and the trap, sealing, testing and handing over.
Scope and safety. Written for trainee and working residential plumbers in Vietnam, and for homeowners who want to know what a good installation looks like. It covers ceramic washbasins that are wall-hung, on a full or half pedestal, or set into or onto a vanity cabinet, in homes typically supplied from a rooftop tank by gravity or by a booster pump, with PPR supply pipes and uPVC drains. It does not cover building new supply or drain lines inside the wall. Figures marked for reference are common examples only, not rules from a standard: always follow the installation instructions and fixing template supplied with the basin, the tap and the waste. If there is an electric instant water heater or a socket near the basin, any electrical work on it (230 V/50 Hz, RCD protection) must be done by a qualified electrician.
Know the basin types before you start
The type of basin decides how it is fixed and how much of the pipework will be on show.
Wall-hung basin: fixed directly to the wall with hanger bolts or brackets. The trap and supply are visible underneath, so a neat chrome bottle trap or P-trap is usually chosen. The wall must carry the full load of the basin plus someone leaning on it.
Full pedestal basin: the basin is still fixed to the wall; the pedestal mainly hides the pipes and gives some support. A common mistake is to rely on the pedestal alone.
Half pedestal (semi-pedestal): a short pedestal hung on the wall under the basin to hide the trap. The drain must come out of the wall, not the floor.
Countertop basins: inset (dropped into a cut-out, rim resting on the top), undermount (fixed under a stone top with brackets or adhesive) or vessel (a bowl standing on the top, needing a tall or wall-mounted tap; many have no overflow).
Unpack and inspect the basin in front of the client for cracks or chips, especially around the fixing holes and waste outlet.

Figure 1. A round white vessel basin standing on a light marble countertop, with a tall single-lever chrome mixer pouring water into it. A vessel basin needs a tall tap like this, a waste chosen to match whether the bowl has an overflow, and a neat seal where the foot of the bowl meets the countertop. (Photo: Traumrune, Wikimedia Commons, CC BY-SA 3.0)
Step 1: Survey the site
The wall
Tap the wall and look at the edge of a socket box or a nearby opening to find out what it is made of:
Solid brick or concrete: the easiest case. Standard nylon wall plugs with the screws or hanger bolts supplied with the basin usually hold well when drilled to the right size and depth.
Hollow brick (gạch lỗ): very common in Vietnamese townhouse partitions. A short plug may only grip a thin web of brick and pull out. Use longer plugs designed for hollow masonry or an injection (chemical) anchor with mesh sleeves, as the anchor maker describes, and try to place fixings where the brick is solid.
Plasterboard or other light partition walls: these cannot carry a basin on their own. Use a basin support frame or a timber or steel backing fixed into the structure before boarding.
Tiles: a hollow-sounding tile may crack when you drill or tighten against it.
Supply and drain points
Find the hot and cold supply stubs (the threaded outlets left in the wall, often 1/2-inch female threads on PPR pipe) and the drain point:
Which stub is hot and which is cold? The usual convention is hot on the left, cold on the right as you face the basin; confirm by running water.
Do the stubs suit the basin and tap, and do they sit far enough out of the finished tile face for an angle valve to screw in cleanly?
Does the drain come out of the wall or the floor, and what size is it? Measure rather than assume, and buy the matching adaptor or rubber reducer.
Is the drain clear? Pour a bucket of water in before you fit anything.
Hidden pipes and cables
A detector helps, but also think: cables often run vertically above or below sockets and switches, and supply pipes run from the stubs. Do not drill in line with the stubs or directly above or below sockets. An electric instant heater or socket near the basin must be on an RCD-protected circuit installed by a qualified electrician, away from splashes.
Step 2: Plan the heights and set out
Agree the finished height of the basin rim with the client. The rim height is often around 80–85 cm above the finished floor (for reference); families with children or elderly users may prefer different heights. Then:
Draw a vertical centre line on the wall, normally on the centre of the drain or of the space between the supply stubs, or where the client wants the basin.
Draw a level line at the planned rim height with a spirit level or a laser.
Use the template or measure the basin. Many basins come with a paper template for the fixing holes. If not, measure from the top of the rim down to the centre of the fixing holes and the distance between them, and transfer this to the wall.
Check the pipes against the basin. Hold the basin (with a helper) against the lines: will the trap line up with the drain, the stubs be hidden by the pedestal or cabinet, and the hoses reach the valves without stretching?
Mark the fixing holes through the basin's fixing holes or from the brackets.
If the stubs or drain are in the wrong place, discuss it with the client before drilling.

Figure 2. A blue steel washbasin support frame fixed in a new apartment before the wall is boarded. The two yellow-sleeved threaded rods at the top will carry the basin; below them are the supply connections, here combined with housings prepared for two water meters. On a light partition wall, a frame or solid backing like this, not the board, carries the basin. (Photo: Kai Kemmann, Wikimedia Commons, CC BY-SA 4.0)
Step 3: Drill and fix the wall anchors
Tape each mark so the bit does not wander on the glaze.
Drill through the tile without hammer action, with a tile bit; use hammer mode only once into brick or concrete, and only if needed.
Drill square to the wall to the depth the plug needs, and clear the dust from the hole.
Set the plugs so they start behind the tile layer, not inside it; a plug expanding inside the tile can crack it.
Fit the hanger bolts or brackets, leaving enough thread to pass through the basin and take the washer and nut.
With injection anchors, wait for the resin to cure as stated on the cartridge before loading them.
Step 4: Fit the tap and waste to the basin before hanging it
Do this with the basin on a padded surface; it is far easier than working under a hung basin.
The tap
Fit the tap's base gasket or O-ring so the tap sits flat on the ceramic.
Screw the flexible supply hoses into the tap body by hand until they are snug, as the tap maker describes. Over-tightening can damage the thread or the O-ring.
Fit the fixing stud, washer and backnut from below and tighten until the tap does not turn, without cracking the ceramic.
For a two-handle mixer, note which hose is hot and which is cold now; it is harder to see once the basin is up.
The waste (drain fitting)
The waste must match the basin:
Basin with an overflow hole: use a slotted waste. The slots must line up with the overflow channel inside the basin so overflow water can drain away.
Basin without an overflow (many vessel basins): use an unslotted waste. A slotted waste on a basin without an overflow can leak water through the slots past the seal.
Fit the waste with the rubber seals supplied, one above and one below the ceramic, as shown in the instructions. Some installers add a thin bead of silicone or plumber's putty under the flange; use these only if the waste maker permits, because some products are not compatible with certain plastics or finishes. Tighten the backnut while holding the waste body so it does not turn and twist the seals.
If it is a pop-up waste, set up the rod or push mechanism so the plug opens fully and closes tightly before the basin goes on the wall.

Figure 3. A white ceramic basin with a two-handle chrome mixer. The round hole below the tap is the overflow; the chrome cap at the bottom is a push-type pop-up waste plug, which appears to be raised (open). A basin with an overflow like this needs a slotted waste lined up with the overflow channel. A small maker's mark on the tap has been blurred. (Photo: deavmi, Wikimedia Commons, CC BY-SA 4.0)
Step 5: Hang and level the basin
With a helper, lift the basin onto the bolts or brackets and fit the plastic or rubber washers supplied against the ceramic, then the nuts.
Check level both ways. Correct with the brackets or thin packers as the maker allows, never by forcing the ceramic.
Tighten the nuts evenly and gently. Ceramic cracks without warning; stop as soon as the basin is firm when pressed at the front.
For a pedestal, slide it in, check the basin rests on it level, and fix it to the floor if it has fixing holes. The wall fixings still carry the basin.
Vanity and countertop basins
Level the cabinet and fix it to the wall as its maker describes so it cannot tip forward; cut neat pipe holes in the back first.
Inset: check the cut-out against the template, run silicone under the rim and press the basin down evenly.
Undermount: use the brackets or adhesive the makers specify and support the basin until it has set.
Vessel: check that the spout reaches the centre of the bowl at a height that does not splash.
Step 6: Connect the supply
Flush the stubs first. Briefly run each stub into a bucket (through a temporary valve if needed) to clear grit and swarf, which otherwise ends up in the new tap cartridge or aerator.
Fit angle stop valves (often called angle valves) on the hot and cold stubs. Wrap PTFE tape on the male thread in the direction of tightening, with the number of wraps suited to the thread, and screw in until the valve outlet points where the hose needs to go. Do not back off to line it up, as this can open a leak path; adjust by tightening a little further if the thread allows.
Connect the flexible hoses from the tap to the angle valves. Hoses should run in a gentle curve, without kinks, twists or tension. Choose the right length; a hose stretched tight or looped tightly will fail early.
Tighten the hose nuts as the hose maker describes. They seal on a rubber washer, so they normally need only a moderate tightening; do not use PTFE tape on a nut that seals with a washer.
Leave the angle valves closed until the waste and trap are connected.
Step 7: Connect the trap to the drain
The trap holds a small amount of water that blocks drain smells from coming into the bathroom. Common choices:
Bottle trap: compact and easy to clean, often used under wall-hung basins.
P-trap (U-trap) to a wall drain: the classic shape, shown in Figure 4.
Trap to a floor drain: where the drain comes out of the floor, a trap with a vertical outlet is used.
Good practice:
Join the trap outlet to the drain with a proper seal, such as the rubber reducer or adaptor made for the drain size. A loose hose pushed into a hole lets smells and insects in.
One trap only. Do not run a basin trap into another trap, such as a floor drain with its own trap, unless the drainage design allows it; two traps in series can trap air and make the basin drain slowly.
Avoid long corrugated flexible hoses as the trap. Hair and soap collect in the ridges and they sag. If space forces their use, keep them short, supported and with a proper water seal.
Keep the trap accessible so it can be cleaned without breaking tiles or a cabinet.
Tighten plastic slip nuts by hand, then a little more if the instructions allow. Over-tightening distorts the seals.

Figure 4. A chrome P-trap under a washbasin, shown in black and white: the waste tail comes down from the basin, curves through the U-bend that holds the water seal and runs back into the tiled wall behind a cover plate. Beside it, a chrome angle valve with a small screwdriver slot feeds the tap through a slim supply pipe. (Photo: Frank C. Müller, Baden-Baden, Wikimedia Commons, CC BY-SA 4.0)
Step 8: Seal the basin to the wall
Clean and dry the joint between basin (or countertop) and wall, run a continuous bead of mould-resistant sanitary silicone, tool it smooth and respect the cure time on the cartridge before the joint gets wet. Silicone is a splash seal, not what holds the basin up.
Step 9: Test everything
Test with the client watching if possible:
Open the angle valves slowly. Check every supply joint with dry tissue paper: the stub-to-valve thread, the hose nuts at both ends and the tap base. Tissue shows a weep before you can see a drip.
Run hot and cold. Check that hot comes from the hot side and the flow is steady. On a rooftop-tank or booster-pump system, also check with another tap or the shower running.
Fill the basin to the overflow with the plug closed. Check that the plug holds and that water drains away freely through the overflow without rising over the rim.
Release the full basin and watch the waste, trap and drain joints while the water rushes through. This is the hardest test for these joints. Repeat two or three times.
Check the trap holds water and there is no smell from the drain.
Press down on the front of the basin to confirm it is firm.
Look again later, or ask the client to check under the basin with a torch the next day; slow weeps can take time to show.
Step 10: Clean up and hand over
Clean the basin, tap and silicone smears, and leave the area dry.
Show the client the angle valves, how to close them, and how to remove the pop-up plug and clean the trap.
Hand over the instruction leaflets and explain the silicone cure time.
Reference table: checks and measurements
Item | What to check | Typical value or method (for reference, follow the manufacturer's instructions) |
|---|---|---|
Wall type | Solid, hollow brick or light partition | Hollow brick: long hollow-masonry plugs or injection anchors; light partition: frame or backing |
Rim height | Agreed with the client | Often around 80–85 cm above finished floor; adjust for users |
Centre line | Basin, drain and stubs aligned | Vertical line on the wall before drilling |
Hot and cold | Correct sides | Hot on the left, cold on the right as you face the basin; confirm by running water |
Stub position | Hidden by pedestal or cabinet if required, reachable for valves | Check against the basin, tap and pedestal before fixing |
Anchors | Right type and depth for the wall | Plug head just inside the tile face; resin cured before loading |
Basin nuts | Firm, even, not over-tightened | Plastic or rubber washer against the ceramic |
Waste type | Matches overflow | Overflow hole: slotted waste lined up; no overflow: unslotted waste |
Supply hoses | Length and route | Gentle curve, no kinks or tension; no PTFE tape on washer-sealed nuts |
Trap | Water seal, single trap, accessible | Proper seal at the drain; removable for cleaning |
Silicone | Continuous and cured | Sanitary, mould-resistant; cure time as on the cartridge |
Leak test | Supply, waste, trap, overflow | Tissue on joints; fill to overflow and release; check again later |
Practical examples
Example 1: The basin that came off the wall
A wall-hung basin in a rented room has started to tilt forward. The previous installer used short plugs in a hollow-brick partition, and they have pulled out of the thin brick webs. The plumber removes the basin, fills the old holes and re-fixes it with injection anchors and sleeves for hollow masonry, offset slightly from the damaged holes, re-hanging the basin once the resin has cured.
Example 2: The leaking vessel basin
A new vessel basin leaves a puddle in the cabinet whenever it is filled with the plug down. The bowl has no overflow, but a slotted waste was fitted, so water escapes through the slots and down the outside of the waste body. An unslotted waste solves it, and the client is warned that the bowl can overflow if the plug is left down with the tap running.
Example 3: The smelly corrugated hose
A homeowner complains of a drain smell. Under the basin a long corrugated hose drops loosely into a hole in the floor, with no seal and a sag full of sludge. The plumber fits a proper trap connected to the floor drain pipe through a sealed adaptor, and the smell is gone.
Common mistakes
Relying on the pedestal or silicone to hold the basin up.
Short standard plugs in hollow brick, or fixing straight into plasterboard.
Hammer-drilling through tiles; over-tightening nuts and cracking the ceramic.
Wrong waste type for the overflow, or slots not lined up.
Not flushing the stubs; swapping hot and cold.
Kinked or stretched hoses; PTFE tape on washer-sealed nuts.
An unsealed waste hose in a drain hole, or double trapping into a floor drain.
Testing with a trickle instead of filling and releasing the basin.
Safety checklist
Main supply or branch valve closed and drained before working on stubs.
Wall checked for hidden pipes and cables before drilling; no drilling in line with stubs or directly above or below sockets.
Safety glasses when drilling tiles and masonry; dust mask in dusty work.
Heavy or large basins lifted with a helper.
Power tools in good condition, used with dry hands, plugged into an RCD-protected outlet.
Any electric water heater or socket near the basin connected by a qualified electrician on an RCD-protected circuit (230 V/50 Hz), and the plumber does not open electrical covers.
Gloves for broken ceramic and cut pipe edges; ventilation when using silicone and adhesives.
Water turned back on slowly and all joints watched during the first fill.
Floor dried after work so no one slips.
Advice for the client
Do not sit on the basin or let children hang from it.
Clean the pop-up plug and trap regularly, and check under the basin for dampness every few months.
If water appears under the basin, close the angle valves, then call a plumber.
Replace braided hoses that show rust, bulges or kinks.
Frequently Asked Questions
What height should a bathroom washbasin be?
There is no single right height. Many rims sit around 80–85 cm above the finished floor (for reference); agree the height with the client, considering who will use it.
Can I install a washbasin on a hollow brick wall?
Yes, with fixings designed for hollow masonry, such as long hollow-brick plugs or injection anchors with mesh sleeves, used as the anchor maker describes. Short standard plugs are not reliable.
Do I need a slotted or unslotted waste?
Use a slotted waste on a basin with an overflow hole, with the slots lined up with the overflow channel. Use an unslotted waste on a basin without an overflow.
Should I use silicone under the waste flange?
Follow the waste maker's instructions. Many wastes seal on their own rubber washers. Some installers add a thin bead of silicone; plumber's putty is not suitable for every product.
Why does my new basin tap have low flow?
Often grit from the pipes has lodged in the aerator or the tap cartridge. Unscrew the aerator and clean it. Flushing the stubs before connecting the tap prevents this.
Practice Exercises
Wall survey. For three walls (concrete, hollow brick, light partition), write which fixing you would use for a wall-hung basin and why.
Set-out. On a training wall, draw a centre line and a level line for a basin rim at a height agreed with a "client", and mark fixing holes from a template.
Tap and waste. On a basin on the bench, fit a mixer with hoses and a pop-up waste. Decide whether the waste should be slotted and explain your choice.
Trap connection. Connect a bottle trap or P-trap to a training drain with a sealed adaptor. Fill and release the basin three times and record any leaks.
Leak test checklist. Write a short checklist for testing a newly installed basin, including what to show the client.
Client explanation. In three or four sentences, explain to a client why their old corrugated waste hose causes smells and what you recommend instead.