Ten minutes into a heavy downpour, water is already spilling over the edge of the gutter and running in streams down the wall; in some houses it even seeps through the plasterboard ceiling near the roof edge. The homeowner calls: "The gutter is blocked, come up and clear it." Often it really is blocked with leaves, but sometimes the gutter is clean and still overflows, because it sags, the downpipe is blocked at the bottom, or the street drain is backing up.
This lesson shows plumbers how to locate and fix faults in the rainwater drainage system on the roof of a house: eaves gutters (metal or plastic gutters hung on the roof edge), concrete box gutters, roof outlets on roof terraces, rainwater downpipes and the inspection chamber at the foot of the pipe. By the end of this lesson, you will be able to trace the path of rainwater, pinpoint where the blockage or overflow really comes from, clear gutters, outlets and downpipes safely, correct the gutter fall and advise the client on preventing re-blockage. Most of the work is at height, so safety comes first. For bathroom drainage, see the lesson Blocked bathroom floor drain, water draining slowly; for the principles of drain pipe fall, see Drain pipe fall and how to prevent bad odours in bathrooms.
Understand the path of rainwater before climbing onto the roof
A house’s rainwater system usually consists of four sections in series. Wherever it overflows, the cause is usually that that section or the section after it cannot drain fast enough.
Collecting surface: metal sheet roof, tiled roof, concrete roof terrace, balcony.
Collecting channel: an eaves gutter hung on the roof edge, a concrete box gutter running along the parapet wall, or a channel on the roof terrace leading to the roof outlet.
Roof outlet and downpipe: the inlet (usually with a leaf guard) connected to the downpipe, most commonly uPVC pipe, running on the outside of the wall or concealed in a service duct.
The foot section: the bend at the foot of the pipe, the horizontal pipe under the floor, the inspection chamber, then out to the public sewer or drainage ditch.
Two things to understand from the start:
Rainwater should have its own route, not be connected to the septic tank or to the toilet waste pipe. Rainwater flowing into a septic tank can fill it quickly and cause backflow (see the lesson Full septic tank: warning signs and when it needs pumping out).
The place where water overflows is not always the place that is blocked. If the downpipe is blocked right at the bottom, water backs up the pipe, fills the outlet and only then overflows the gutter.
Signs and quick fault location
Observe while it is raining from the ground or inside the house, without climbing onto the roof; record a short video to compare once the rain stops.
What you see during rain | Suspected location | Check once the rain stops |
|---|---|---|
Water spills over the gutter edge along one section, other sections are normal | The gutter sags or debris has collected in that section | Look along the gutter, pour in test water, measure the fall |
Overflow all along the gutter, very weak or no flow from the pipe outlet at the bottom | The roof outlet or downpipe is blocked | Remove the leaf guard, flush test water down the downpipe |
Overflow although the gutter is clean and the pipe foot is discharging at full bore | The gutter or downpipe is too small for the roof area, or there are not enough downpipes | Count the downpipes, estimate the roof area each one must serve |
The roof terrace stays flooded for a long time, water up to the door threshold | The terrace outlet is covered, the floor falls the wrong way | Clear around the outlet, watch where the water drains to |
Water seeps or sprays out of downpipe joints near the bottom | Blockage at the foot bend or horizontal pipe, the downpipe is full of water | Tap along the pipe, open the foot bend or access cover |
The inspection chamber at the pipe foot is full and the street drain is also flooded | Not a blockage in the house; the public sewer is overloaded or there is a high tide | Watch when the sewer drains down; consider a non-return (anti-backflow) valve |

Tools and protective equipment to prepare
Tools and materials | Used for | Notes |
|---|---|---|
A-frame ladder or extension ladder of sufficient height, with non-slip feet | Reaching the roof edge and the gutter | Check the locks, rungs and feet |
Full-body harness + lanyard | Working on pitched roofs, near the roof edge, on roof terraces without railings | Only clip onto a solid anchor point |
Heavy gloves, safety glasses, non-slip shoes | Protecting hands from sheet metal edges and screws | Never go on the roof in flip-flops |
Plastic trowel, small shovel, bucket with a hanging hook | Scooping debris out of the gutter | Do not scrape plastic or painted gutters with metal tools |
Hose with a shut-off nozzle | Water testing and rinsing | Moderate flow, do not spray into roof joints |
Drain cleaning spring cable (hand-cranked) | Clearing the downpipe and foot bend | Choose a cable size to suit the pipe diameter |
Spirit level, string line, tape measure | Measuring the gutter fall |
Step 1. Assess safety before working at height
This step is compulsory, even when the job "only takes ten minutes".
Do not work while it is raining, during thunderstorms, in strong wind, or after dark. Wet, mossy roofs are very slippery.
Power lines around the roof edge: keep your distance and do not let aluminium ladders, poles or spring cables touch them. If there are bare or damaged wires close to the gutter, stop work and tell the homeowner to contact the electricity company.
Roof type: do not step on translucent roof sheets, fibre-cement sheets or old tiles, as they can break through. On metal sheet roofs, only step along the screw lines (where the sheet rests on the purlins).
Ladder: set it on firm, level ground; lean it against the wall, not against a plastic or thin metal gutter. The ladder angle usually follows the "4 up, 1 out" rule; if you step from the ladder onto the roof, the top of the ladder should extend about 1 m above the landing point (both are reference figures). Have someone hold the foot of the ladder; always keep three points of contact and do not lean out from the ladder.
On pitched roofs, near the roof edge, on roof terraces without railings: wear a full-body harness clipped onto a solid anchor point. If there is no reliable anchor point, do not do the work; propose scaffolding or another method.
At least two people: one person stays below to hold the ladder, pass up tools and guard the area where debris may fall.
Step 2. Clear debris from eaves gutters and box gutters
Temporarily cover the outlet opening (a rag, or a plastic bag loosely tied) so that debris does not fall into the downpipe.
Set up the ladder at the end furthest from the outlet and work towards the outlet, so debris is not pushed into the outlet opening.
Scoop out the debris, including the wet humus layer on the bottom of the gutter, with a plastic trowel or gloved hands, and put it in the bucket hung on the ladder. Do not sweep debris down into the yard or onto the neighbour’s property.
Only after all the debris has been scooped out, rinse gently with the hose to wash away fine sediment.
Plants growing in the gutter (Figure 2) must be pulled out with their roots. If plants have rooted into roof joints or box gutter cracks, cut them off flush and note their position for waterproofing work later; do not yank them out and crack the mortar.
If you find a wasp or hornet nest, stop; do not deal with it yourself on a ladder. Tell the homeowner to call a pest control specialist.

Step 3. Clear the roof outlet and leaf guard
On roof terraces and flat roofs, water collects at a roof outlet with a dome cover or leaf guard. This cover is often blanketed with leaves, plastic bags and sand: it looks normal, but the water cannot get through.
Remove the debris covering the dome cover or leaf guard.
Remove the dome cover or lift out the guard and shine a torch into the throat of the outlet. Remove debris, sand and gravel stuck in the throat by gloved hand or with a hook.
Check around the outlet: cracks, peeling waterproofing, gaps between the outlet body and the concrete slab. This spot often leaks into the ceiling below (for how to locate leaks, see the lesson Bathroom leaking into the ceiling of the floor below).
Refit the dome cover or leaf guard securely and the right way up. If the cover is missing, fit a new one of the right size; never leave the outlet open.

Step 4. Water test and clear the downpipe
4.1. Testing with water
One person pours water into the outlet (hose or a bucket of water), while the other stands at the discharge at the pipe foot or opens the inspection chamber cover to watch.
Pipe clear: water comes out at the bottom almost immediately and flows steadily; nothing stands in the outlet.
Partial blockage: water comes out slowly and weakly, water stands in the outlet, and you hear gurgling in the pipe.
Complete blockage: the outlet fills up and the pipe foot stays dry.
On pipes running outside the wall, you can tap gently along the pipe with a screwdriver handle: sections full of water or sludge sound dull; empty sections sound hollow. Water stands above the blockage, so the blockage is usually around the point where the sound changes from dull (above) to hollow (below).
Note: if the water is not going down, stop pouring. The higher the column of water in the downpipe, the greater the pressure on the lower joints (a water column about 10 m high creates roughly 1 bar), while solvent-welded drain pipe joints are not designed to hold pressure and can seep or blow apart.
4.2. Clear from the bottom first if possible
The blockage is usually at the foot bend (where the downpipe turns horizontally into the floor) or in the inspection chamber, because debris collects at the first change of direction.
If the pipe foot has an access cover (rodding eye), put a bucket and tarpaulin underneath and open it slowly. A pipe full of water will discharge forcefully and dirtily: stand to one side and wear safety glasses.
Remove the debris at the foot bend, then feed the spring cable upwards and along the horizontal pipe to pull out the rest.
If the foot bend is solvent-welded with no access cover and the blockage is severe: you can cut the pipe at a low point to remove the debris, then rejoin it with a coupling, fitting an access cover at the same time (see Solvent welding uPVC pipe correctly). Agree with the homeowner before cutting.
4.3. Clearing from the top
Remove the leaf guard and feed the spring cable down from the outlet, pushing while turning steadily. When you meet a hard spot, turn so that the cable head hooks the debris, then pull it out.
Once the cable gets past the blockage, flush with water to wash away the rest.
Electric drain cleaning machines should only be used once you have been trained: plug in through a socket with residual current protection (RCD/ELCB), keep the power cable out of water, and never operate it on a ladder.
Do not pour in chemical drain cleaners: chemicals hardly dissolve leaves, plastic bags, sludge and sand, they sit in the pipe, and they can easily splash on you when the pipe is opened.
A pressure washer is only used for rinsing after the pipe has been cleared; do not spray into roof joints or gutter joints.
Step 5. Check the inspection chamber and the run to the sewer
Open the inspection chamber cover and let it air for a few minutes before bending over to look. Closed chambers and sewers can accumulate toxic gases and lack oxygen. Never climb down into an inspection chamber or underground sewer.
Scoop out debris and sludge with a long-handled scoop; check whether the outlet pipe to the sewer is silted up.
If the chamber is full of clear water while the public sewer in the street is also flooded, the sewer is overloaded or there is a high tide; it is not a blockage in the house. Note it down to advise the homeowner (for example raising the floor level or fitting a non-return valve). The public sewer outside belongs to the drainage authority; plumbers must not break into it themselves.
Step 6. Check the gutter fall and condition
If the gutter is clean but long puddles still stand in it, check the fall. The gutter must fall towards the outlet; it must not sag in the middle or fall the wrong way.
Pour water at the furthest end; any section where water still stands after you stop pouring is a sag.
Stretch a string line from the end of the gutter to the outlet, or lay a spirit level along the gutter bed, to check the direction of fall.
Check the hangers and brackets: broken or rusty hangers, loose screws or hangers spaced too far apart make the gutter sag. Replace or add hangers according to the gutter manufacturer’s instructions.
Check the joints, corners and stop ends: if the sealant or gaskets have aged, redo them; if a metal gutter has rusted through at the bottom, a patch is only temporary and the section should be replaced.
Example: calculating the height difference when correcting the fall
Eaves gutters usually need only a slight fall; many gutter manufacturers specify a few millimetres per metre of length (reference; follow the instructions of the gutter brand you are using). Suppose you choose 3 mm/m (reference) for an 8 m long gutter:
Height difference between the gutter end and the outlet = 8 m × 3 mm/m = 24 mm.
Stretch a string line from the first hanger (high) to the last hanger (24 mm lower), then adjust the hangers in between to touch the line exactly.
Step 7. Test run, handover and preventing re-blockage
7.1. Test run
Remove all the rags and temporary bags from the outlet openings.
Pour water from the far end of each gutter and into each outlet; the person below watches the water come out at the pipe foot and inspection chamber.
Check the downpipe joints and any section you have just cut and rejoined: no seepage.
Take before and after photos and send them to the homeowner.
7.2. Preventing re-blockage
Leaf guards at the pipe inlets and roof outlets (Figure 5) or gutter mesh reduce the debris getting into the downpipe, but they themselves get covered with leaves, so they still need clearing.
Trim tree branches overhanging the roof (arranged by the homeowner, recommended by the plumber).
Inspection schedule: at least before the rainy season and after the leaf-fall season; houses near large trees should be checked more often (reference).
Roof terraces with parapet walls should have an emergency overflow opening (Figure 4) lower than the door threshold, so that if the outlet is blocked the water overflows to the outside rather than into the house. Cutting through the wall involves the structure and waterproofing: only propose it, and agree it with the homeowner and a qualified professional.
If the system is clean but still overflows in heavy rain: the gutters or downpipes may be too small or too few for the roof area (common when the roof has been extended). It needs recalculating; for larger buildings, call in a plumbing and drainage engineer.


Safety checklist
Weather: dry, no rain, no thunderstorms, no strong wind, enough daylight.
Electricity: checked the power lines around the roof; the ladder, spring cable and poles do not touch any wires. Electric drain cleaning machines plugged into a socket with residual current protection, power cable dry, not operated on a ladder.
Roof: no stepping on translucent sheets, fibre-cement sheets or broken tiles; on metal sheet roofs, step along the screw lines.
Ladder and fall protection: sturdy ladder, leaning on the wall and not the gutter, someone holding it; three points of contact; full-body harness when working on pitched roofs or near unguarded edges.
PPE: heavy gloves, safety glasses, non-slip shoes.
Pipes full of water: stand to one side when opening access covers or foot bends, with a bucket and tarpaulin underneath.
Chemicals: no chemical drain cleaners in rainwater pipes.
Inspection chambers: open the cover to air it first; never climb down into chambers or underground sewers.
Insects: if you find a wasp or hornet nest, stop work and inform the homeowner.
Area below: cordon it off so nobody walks into the zone where debris or tools may fall; collect debris in bags.
Real-life scenario
A town house with a metal sheet roof and a 10 m metal gutter overflowing in the middle. Pouring water from the far end: water stands in the middle section, the pipe foot still flows well, and there are only a few leaves in the gutter. Stretching a string line shows that the two middle hangers have rusted and broken, so the gutter sags. Fix: replace the hangers, add extra hangers, correct the fall to the line, and pour water again to see it all drain to the outlet. The cause was broken hangers, not a blockage.
Working with clients
Ask before you go: type of roof, number of floors, access to the roof, where the water overflows, whether they have photos or videos taken during rain. For tall houses or pitched roofs without anchor points, bring extra people and equipment, or decline the job if safety cannot be ensured.
Quote by item: clearing gutters, clearing downpipes, repairing hangers and correcting the fall, replacing gutter sections, fitting leaf guards. Tell the client in advance about extra work (cutting pipes, fitting access covers).
Do not promise "no more overflowing, ever" when the cause is too few downpipes, undersized gutters or a backed-up street sewer; explain clearly which parts the plumber can fix and which need major alterations.
Frequently asked questions
How often should gutters and rainwater outlets be cleared?
There is no single figure. Check at least before the rainy season and after the leaf-fall season; houses near large trees or where birds nest should be checked more often (reference).
Should chemical drain cleaner be poured into rainwater pipes?
No. Rainwater pipes are usually blocked by leaves, plastic bags, sludge, sand and dropped objects, which chemicals can hardly dissolve; the chemicals also sit in the pipe and can easily splash on you when the pipe is opened. Using a spring cable and opening the foot bend or access cover is more effective and safer.
Once leaf guards are fitted, do they still need clearing?
Yes. The guards keep debris at the top so it does not go down the downpipe, but over time leaves building up around the guard will also seal off the water path.
Can rainwater pipes be connected to the septic tank or the toilet waste pipe for convenience?
That is not advisable. Rainwater should have its own route to the inspection chamber and drain. Connecting them makes the septic tank fill quickly and it may back up in heavy rain. If you find a house that is already connected this way, note it down and advise the homeowner to separate the lines.
What if the gutter is clean but still overflows in heavy rain?
Check in turn: the gutter fall, whether the downpipe is clear, whether the pipe foot and inspection chamber drain, and whether the street sewer is flooded. If everything is fine and it still overflows, the gutters and downpipes may not be large enough for the roof area and need upsizing or additional downpipes; for larger buildings, call in an engineer to do the calculations.
Practice exercises
Draw the rainwater drainage diagram of a house you know: roof, gutters, outlets, downpipes, inspection chamber and route to the sewer; mark where there are leaf guards and access covers.
Practise using a ladder safely at ground level: set the ladder at the correct angle (reference), check the feet and locks, and practise climbing up and down with three points of contact while someone holds it.
Measure and correct the fall: lay a sample gutter section on the ground, stretch a string line, calculate the height difference using the reference fall, and pour water to see whether it all drains to the low end.
Simulated unblocking: stuff shredded paper and dry leaves into the 90° bend of an upright uPVC pipe section, and practise feeding the spring cable from the top down and from the bottom up to pull the debris out.
Advice role play: the homeowner asks "you cleared the gutter, so why does it still overflow in heavy rain?". Explain in 2 minutes and propose the next inspection step.