A fridge that is not cooling usually has one of six groups of causes, checked from easy to hard: power and settings, the door and gasket, where the fridge stands and its condenser, the defrost system and evaporator fan (in frost-free fridges), the compressor starting circuit or inverter board, and finally refrigerant, a blocked line or a weak compressor. New technicians tend to jump straight to "it's out of gas", when a great many cases are simply an evaporator iced over because the defrost heater has failed. This lesson goes through each step with real readings, with an example of a two-door fridge whose fresh food compartment has risen to 14°C, from the phone call to the quote.
By the end of this lesson, you will be able to:
- Question the customer and measure both compartments with a thermometer to tell "the whole fridge is warm" from "only the fresh food side is warm".
- Check settings, door gasket, clearance and condenser in the first 15 minutes.
- Recognise an iced-up evaporator, defrost manually, and test the defrost heater, defrost thermostat and evaporator fan.
- Check the compressor starting circuit on a standard fridge, and explain why you never put 220V directly on an inverter compressor.
- Decide when a refrigeration technician must measure pressure, braze and recharge, and write a quote that adds up.
Learning appliance repair properly? Repairing standard and inverter fridges is step 4 of the roadmap, after electrical safety, component testing and basic schematics. See the 8-step appliance repair roadmap to learn in the right order.
How does a fridge cool?
A fridge does not "make cold"; it moves heat from inside to outside. The compressor squeezes refrigerant into hot high-pressure vapour, the refrigerant gives off heat in the condenser (usually on the back or sides of the cabinet), passes through a thin capillary tube to drop its pressure, then evaporates in the evaporator inside the fridge and absorbs heat. A fault anywhere in this loop means poor cooling.
Manual-defrost and frost-free fridges
- Manual defrost (direct cooling): the evaporator is the freezer wall, frost is visible and the owner defrosts by hand. Few parts; common in small and older fridges.
- Frost-free (indirect, no-frost): the evaporator is hidden behind the freezer back panel, and a fan blows cold air into the fresh food compartment through air vents. An automatic defrost system (defrost heater, defrost thermostat or sensor, and a timer or control board) switches on the heater periodically to melt the frost.
Standard and inverter fridges
A standard fridge runs its compressor directly on 220V mains, switched by a thermostat or board, and started through a start relay and an overload protector. An inverter fridge uses a variable-frequency board to drive the compressor faster or slower as needed. The compressor checks for the two types are completely different.
Refrigerant in newer fridges
Many newer fridges use R600a (isobutane), which is flammable; older ones often use R134a. The insulation foam in the walls may be blown with a flammable agent such as cyclopentane, with a warning on the label on the back (Figure 1). Read the label before working, to know the refrigerant type, power and voltage.
Photo: Kiwi128 / Wikimedia Commons, CC0
Safety before you touch the fridge
Safety warning: Unplug the fridge before removing any panel, fan or board; plug it back in only when you need a live reading and your test leads are secured. Inverter boards have large capacitors that stay charged for minutes after unplugging: wait and check before touching. Never chip ice off the evaporator with a knife, screwdriver or sharp object: a punctured tube leaks refrigerant, and with flammable R600a you must put out all flames, ventilate, and not switch any electrical switch nearby. Never use a torch or a hot dryer close to the evaporator or plastic liners. Defrost water spreads across the floor near sockets: dry it and lay towels down first. Fridges are heavy, so use two people to pull one out from the wall or tilt it. Brazing and recharging are jobs for a trained refrigeration technician with tools for the right refrigerant.
Tools you need
- A digital probe thermometer or fridge thermometer, a multimeter and a clamp meter.
- Screwdrivers, a torch, towels, a basin for water, a hair dryer on a warm setting (only where allowed, kept away from the coil and plastic).
- A power strip protected by a residual current device (RCD) for live tests.
Safe measurement with a multimeter
Most readings in this lesson are resistance and continuity with the fridge unplugged. If you are not yet confident choosing ranges, review the lesson on using a multimeter as an electrician before working on fridges.
Steps 1–3: the quick checks in the first 15 minutes
Step 1: ask and measure the real temperature
Ask: did it stop cooling suddenly or gradually, both compartments or only the fresh food side, can you hear the compressor running, has it just been moved, was there a power cut, is there an error on the display. Put a thermometer in the middle of the fresh food and freezer compartments for at least 15–30 minutes with the doors shut (Figure 2). Common reference points: fresh food about 3–5°C, freezer about −18°C.
Photo: USDAgov / Wikimedia Commons, Public domain
Step 2: power and settings
- Interior light on and display working: the fridge has power. Measure the socket voltage when the compressor starts; very low voltage can stop it starting.
- Check whether the dial or setting has been turned to the warmest level, or the fridge is in showroom, eco or holiday mode (see the user manual).
- If the fridge was just transported lying down or tilted, many makers advise standing it upright for a few hours before plugging in; read its manual.
- If it was just switched on or filled with warm food, the fresh food side needs a few hours and the freezer may need around 24 hours to reach temperature.
Step 3: door, gasket and location
Close the door on a sheet of paper and pull it: if it slides out easily, the gasket is leaking there. A torn or hardened gasket, a sagging door, or a cable or object caught at the door edge (Figure 3) lets warm humid air in constantly, so the evaporator ices up quickly and the fridge cools poorly. Check clearance: a fridge pushed against the wall, next to the stove, or with things piled on top cannot shed heat from its condenser. A condenser coated in thick dust needs cleaning with a soft brush, unplugged.
Photo: Lizlemonhead / Wikimedia Commons, CC BY-SA 4.0
Step 4: an iced-up evaporator and the defrost system
This is a very common fault in frost-free fridges: the freezer is still fairly cold, the fresh food side gets warmer, and sometimes you hear the fan blades hitting ice. Frost covers the evaporator, so the fan cannot blow cold air to the fresh food side.
How to recognise it
- The fresh food side is far above the reference; the freezer still has ice but is not deeply cold.
- With the back panel of the freezer removed (unplugged), you see solid white frost covering the coil, sometimes jamming the fan.
- After a manual defrost the fridge cools normally for a few days and then the fault returns: almost certainly a defrost system failure.
Manual defrost as a test
Unplug, open the doors, remove the food, lay towels and a basin. Melting naturally usually takes many hours; an ordinary fan blowing room air into the fridge helps. Do not chip the ice with anything sharp. When it is completely dry, plug it back in and monitor the temperature. If it cools again, the next step is to test the defrost parts to fix the root cause.
Testing the defrost heater, defrost thermostat and evaporator fan
- Defrost heater: unplug its connector and measure resistance across it. Open circuit (infinite on the ohm range) means it has failed. Normal values vary by fridge; compare with the figure on the part or the maker's data.
- Defrost thermostat (bimetal or sensor): the mechanical type closes when cold and opens when warm; test continuity while it is still below 0°C and compare with a new part of the same type. Electronic sensors are checked for resistance against the maker's table.
- Defrost timer or board: mechanical fridges use a rotary timer that switches between compressor running and defrost; electronic fridges use a control board, so read the error codes or the maker's test mode.
- Evaporator fan: stiff when turned by hand, an open winding, or powered but not spinning means a failed fan.
Step 5: the compressor does not run, or starts and cuts out
Standard fridge: start relay and overload
Sign: the fridge has power and the light is on, but you cannot hear the compressor, or you hear a "click" and it cuts out after a few seconds, over and over. Unplug, remove the terminal cover on the compressor, and check the start relay (often a PTC type on many fridges) and the overload protector: if the overload is open, the compressor never gets power; if the start relay has failed, the compressor hums, heats up and is cut by the overload. Measure the three winding terminals (C common, S start, R run): the S–R reading should be roughly equal to C–S plus C–R, and no terminal may be shorted to the casing.
Inverter fridge: never apply 220V directly
An inverter compressor is powered by the variable-frequency board and does not run directly on mains. Never wire 220V straight to the compressor "to test it"; you can destroy it. Diagnose using the error code on the display and the maker's test mode, measure the supply into the board, and check that the three compressor windings read the same. If the board is faulty, replace it with the correct part or send it for board repair.
Thermostat and fresh food temperature sensor
Mechanical fridges: a thermostat that does not close leaves the compressor off even when the fridge is warm. Turn the dial to the coldest setting and listen for a "click"; test continuity at the coldest setting. Electronic fridges: a sensor that reads wrong makes the board think the fridge is already cold enough; measure its resistance and compare with the maker's table.
Step 6: the compressor runs constantly but it still does not cool
When the compressor runs all the time, the condenser barely warms up and the evaporator frosts only partly instead of evenly, the fault is usually inside the refrigerant circuit: low refrigerant from a leak, a moisture or dirt blockage in the capillary or filter drier, or a weak compressor that cannot build pressure. The table below summarises how to read the signs.
| Sign | Suspect | Who fixes it |
|---|---|---|
| Freezer cold, fresh food warm, coil fully frosted | Defrost system failure, evaporator fan jammed | Appliance technician replaces parts |
| Light on, compressor silent or clicks and cuts out | Start relay, overload, thermostat, board | Appliance technician tests and replaces |
| Compressor runs, evaporator fan does not turn | Failed fan, no power to the fan, jammed by ice | Appliance technician |
| Compressor runs constantly, condenser only slightly warm, coil partly frosted | Low refrigerant from a leak, blocked capillary or drier | Refrigeration technician measures pressure, brazes, recharges |
| Compressor runs unusually hot or loud, coil not cold | Weak or failed compressor | Refrigeration technician; weigh up a new compressor or a new fridge |
When to call a refrigeration technician
To know for sure whether refrigerant is low or a line is blocked, you must connect a manifold gauge set to the system (Figure 4), find the leak, braze the tube, pull a vacuum and charge the correct type and amount of refrigerant shown on the label. This needs dedicated tools and skills, especially with flammable refrigerants. At this step you narrow the fault down correctly and pass the job on; never cut tubes or "top up gas" by feel.
Photo: U.S. Navy photo by Mass Communication Specialist 3rd Class Jon Husman / Wikimedia Commons, Public domain
Repair or replace the fridge
For an old fridge that needs a new compressor plus a recharge, the cost can approach a large share of a new fridge. Give the customer both options with concrete figures and let them decide.
Worked example: a two-door fridge at 14°C in the fresh food side
A customer calls: a 7-year-old two-door frost-free fridge, the fresh food side has not been cold for a few days and the vegetables are wilting, but the freezer still has ice. No error on the display, not recently moved.
Steps at the customer's home
| Step | Result | Minutes |
|---|---|---|
| Ask questions, put thermometers in both compartments | Fresh food 14°C, freezer −9°C; compressor running | 10 |
| Check settings, gasket, condenser | Settings correct, gasket sealing, good clearance behind | 10 |
| Unplug, remove the freezer back panel | Frost covering the evaporator, fan blades jammed by ice | 15 |
| Test the defrost parts | Defrost heater open circuit; defrost thermostat closed when cold; fan spins freely once ice is cleared | 10 |
| Defrost the coil (room-air fan, towels, basin) | Coil clear of frost and dry | 60 |
| Replace the defrost heater, reassemble, power on and test | Fan running, cold air blowing into the fresh food side | 25 |
Total time on site: 10 + 10 + 15 + 10 + 60 + 25 = 130 minutes. Follow-up after 24 hours: fresh food 4°C, freezer −18°C.
Quote (2026 reference, varies by region and model)
- Defrost heater, correct part: 180,000 VND (about 7 USD).
- Labour for diagnosis, defrosting and part replacement: 250,000 VND.
- Call-out fee: 50,000 VND.
- Total: 180,000 + 250,000 + 50,000 = 480,000 VND.
Some other reference prices in Vietnam: start relay or overload replacement about 150,000–400,000 VND; evaporator fan about 300,000–700,000 VND; leak repair and recharge about 600,000–1,500,000 VND; a new compressor from about 1,500,000 VND upwards depending on type (2026 reference, varies by region, labour included or not depending on the shop).
Why not say "it's out of gas"
The freezer was still at −9°C and the frost on the coil was thick and even: the refrigerant circuit was still cooling, but the cold air was not being blown to the fresh food side. Quote a recharge, and the customer pays for nothing and the fridge fails again.
Common mistakes of new technicians
Concluding "out of gas" before checking the defrost
Sign: a few days after a recharge the fridge stops cooling again. Cause: the real fault was the defrost heater or thermostat. Avoid it: follow the order, and remove the panel to look at the evaporator before thinking about refrigerant.
Chipping ice with a knife
Sign: a hissing sound, a strange smell, the fridge stops cooling completely. Cause: a punctured evaporator tube. Avoid it: defrost only by letting the ice melt naturally or with room-temperature air, as the maker instructs.
Putting 220V directly on an inverter compressor
Sign: the compressor does not run and there is a burning smell. Cause: mistaking an inverter fridge for a standard one. Avoid it: read the label and identify the inverter board before testing.
Forgetting the 24-hour check
Sign: the customer calls back because the freezer is still not cold enough. Cause: the repaired fridge had not had time to reach temperature, or a second fault remained. Avoid it: arrange a call or visit to measure again and write the readings on the warranty slip.
Frequently asked questions
The fresh food side is not cold but the freezer is. What is wrong?
In frost-free fridges the most common cause is an evaporator iced up by a failed defrost heater, defrost thermostat or timer/board, or a failed or jammed evaporator fan. Food blocking the air vent into the fresh food side can cause the same symptom.
The fridge runs but does not cool. Is it out of gas?
Possibly, but it is not the first thing to suspect. Refrigerant does not "run out" by itself; if it is low, it has leaked somewhere. Check power, settings, gasket, condenser and defrost first; to conclude that refrigerant is low you must measure pressure.
How long does a new fridge take to get cold?
The fresh food side usually needs a few hours and the freezer may need about a day to stabilise, longer if loaded with warm food. Check the fridge's user manual.
How much does it cost to fix a fridge that is not cooling?
It depends on the cause: defrost parts or a relay cost a few hundred thousand VND; leak repair and recharge about 600,000–1,500,000 VND; a new compressor from about 1,500,000 VND upwards (2026 reference in Vietnam, varies by region and model).
Can I defrost my fridge myself at home?
Yes, if you unplug it, let the ice melt naturally, never chip it with sharp objects and dry everything before plugging back in. If it ices up again within a few days, have a technician check the defrost system.
Practice tasks and self-assessment
- Measure the fresh food and freezer temperatures of 3 different fridges, recording the settings and age of each.
- On a scrap or training fridge, remove the freezer panel and identify the evaporator, defrost heater, defrost thermostat and fan.
- Measure the three compressor terminals on a standard fridge, check that S–R is roughly C–S plus C–R and nothing is shorted to the casing.
- Write a quote for an evaporator fan replacement using the template above, with figures that add up.
Self-assessment criteria
- Pass: thermometer readings before and after the repair, and all 6 steps done in order.
- Pass: you can locate and test the defrost heater, defrost thermostat and evaporator fan with the fridge unplugged.
- Pass: you can tell a job you can fix from one for a refrigeration technician and explain why to the customer.
- Not yet: chipping ice with sharp objects, putting 220V directly on an inverter compressor, or quoting a recharge without removing the panel to look at the evaporator.
The "ask, measure, narrow down from easy to hard" method here is the same one you used for washing machines in the lesson washing machine not spinning. Once fridges are solid, move on to the next roadmap step: Microwaves, rice cookers, induction hobs & water heaters, where you learn to replace fuses and thermal cut-offs and test IGBTs and heating elements.
Keep learning appliance repair: after fridges come microwaves, rice cookers, induction hobs, water heaters, sourcing replacement parts and pricing repairs. See the 8-step appliance repair roadmap.