Tube light fittings with a ballast and starter are still common in homes, rented rooms and shops. When a fluorescent tube has blackened ends or keeps flickering without lighting up, customers often ask: “Can we just switch to LED?” Yes, but it is not simply a matter of pulling out the old tube and plugging in an LED tube.
Some LED tubes keep the ballast and only replace the starter; others require the ballast to be removed and wired directly to 220 V, and these are further divided into single-ended and double-ended supply. Wire the wrong type and at best the tube won't light; at worst you get a short circuit, a tripped breaker or a tube that burns out the first time it is switched on.
By the end of this lesson, you will be able to identify the type of tube and ballast, remove the ballast and starter, rewire the fitting, label it, test the light and troubleshoot faults.
Rule number 1: Each brand and each LED tube model may be wired differently. Always follow the wiring diagram printed on the tube itself or on the box of the exact tube you are installing. The diagrams in this lesson are only to help you understand the principle. Before opening the fitting: switch off the circuit breaker, hang a warning sign and measure to confirm there is no voltage. Review the 5 mandatory safety rules before touching any electrical wire.
How does an old fluorescent fitting work?
A traditional T8 fluorescent fitting consists of: the tube (2 pins at each end, G13 base, with a filament between the 2 pins), a magnetic ballast (an iron-cored coil connected in series to produce the striking pulse and limit current), a starter (which opens and closes at switch-on to preheat the filaments) and two lampholders.
Current path: line through the switch → ballast → pin 1 at end A; pin 2 at end A → starter → pin 1 at end B; pin 2 at end B → neutral. That is why, when switched on, the tube flickers a few times before lighting up.
Fittings with an electronic ballast have no starter; the ballast is an electronic circuit box with several output wires connected to the pins at both ends of the tube.

Types of T8 replacement LED tubes on the market
T8 LED tubes look alike (0.6 m or 1.2 m long, G13 base). The difference lies in the power circuit (driver) inside and how the power is supplied, which you must read on the tube or the box — do not guess from the appearance.
Type 1: works with a magnetic ballast, starter replaced with an LED starter
The tube runs through the existing magnetic ballast: remove the old starter, insert the supplied LED starter (dummy starter, fuse starter) and fit the tube. An LED starter basically connects its two pins together; some include a fuse.
Advantages: no need to open the fitting or rewire.
Disadvantages: the ballast remains in the circuit, still wastes power and may hum; if the ballast fails, the light goes out even though the tube is fine.
Only use the starter supplied or specified by the tube manufacturer; never short out the starter holder yourself with a piece of copper wire.

Type 2: works with an electronic ballast (plug and play)
Some tubes are marked compatible with electronic ballasts: they fit straight into a fitting with an electronic ballast without rewiring, but they only work reliably with ballasts on the manufacturer's compatibility list; with the wrong ballast they may flicker, not light or fail early. If there is no clear compatibility documentation, it is better to remove the electronic ballast entirely and use a direct-wire tube (type 3) or replace the whole fitting with an LED fitting (type 4).
Type 3: direct wire to 220 V, ballast and starter removed
This is the common conversion in renovation work: the driver inside the tube takes mains power directly. The tube is usually printed with “AC 220–240V”, “Direct wire”, “Remove ballast/starter” together with a pin diagram. There are two supply types that are wired completely differently:
a) Single-ended supply: line and neutral both go to the two pins at one end of the tube; the other end is not powered and only holds the tube in place (unless the manufacturer says otherwise). The powered end is usually marked “Input”, “L N” or with an arrow. If fitted the wrong way round, the tube will not light.
b) Double-ended supply: line goes to one end and neutral to the other end (the top diagram in Figure 1). Many tubes of this type connect the two pins at the same end together internally, so putting both line and neutral into one end can cause a direct short circuit.

Some “hybrid” tubes can run either with a ballast or wired directly; each installation method has its own diagram, so read it carefully.
Type 4: integrated LED fitting (tube and fitting as one unit)
The neatest option: remove the entire old fitting, install a new LED fitting, and connect line, neutral (and earth if present) to the terminal block according to the label. Suitable when the old fitting is rusty, the lampholders are brittle or broken, or the wiring inside has become stiff and cracked.
Reference table: comparing the options
This table is for reference for common T8 tubes; check the actual specifications on the product.
Option | Ballast | Starter | Rewire the fitting? | Notes |
|---|---|---|---|---|
Tube for magnetic ballast | Keep | Replace with LED starter | No | The ballast still wastes power and can still fail |
Tube compatible with electronic ballast | Keep | None | No | Must be on the manufacturer's compatibility list |
Direct wire, single-ended supply | Remove | Remove | Yes | L and N at the same end; fit the powered end correctly |
Direct wire, double-ended supply | Remove | Remove | Yes | L at one end, N at the other |
Integrated LED fitting | Replace the whole fitting | None | New installation | Neatest, but uses more materials |
Equivalent power ratings commonly seen on packaging (for reference, not a standard):
Tube length | Typical T8 fluorescent tube | Typical replacement T8 LED tube |
|---|---|---|
0.6 m | about 18–20 W | about 9–10 W |
1.2 m | about 36–40 W | about 18–20 W |
The fluorescent wattage does not include magnetic ballast losses. When comparing brightness, compare luminous flux (lm) rather than just watts.
Identifying which ballast the fitting uses
Switch off, remove the tube, remove the ballast cover and inspect it before buying tubes.
Sign (for reference) | Magnetic ballast | Electronic ballast |
|---|---|---|
Starter | Present | None |
Shape, weight | Long, solid block, heavy in the hand because of the iron core | Thin box, noticeably lighter |
Number of output wires | Usually 2 wires (or 2 terminals) | Usually several wires, connected to both ends of the tube |
Label | W and A ratings, often stating use with a starter | Usually marked “electronic ballast”, “EB” |
When switched on | Flickers a few times then lights, may hum | Lights almost instantly, usually silent |
The surest way is to read the ballast label; if you cannot read it, remove the ballast and wire directly, or replace the fitting.
Tools and materials
Testing equipment and tools: voltage tester, multimeter (see how electricians use a multimeter), screwdrivers, cutters and wire strippers with insulated handles.
Materials: LED tubes of the correct type, lever connectors or terminal strips, spare G13 lampholders, labels.
Protective equipment: a sturdy ladder, safety glasses, gloves, and a rigid box for the old fluorescent tubes.
Converting a fitting to a direct-wire LED tube: 8 steps
This procedure covers the most common case: removing the ballast and starter and wiring directly to 220 V. For type 1 tubes, simply switch off, replace the starter with the LED starter, fit the tube and test the light as in Step 8.

Step 1. Switch off and confirm by measurement
Switch off the lighting circuit breaker (if unsure, switch off the main breaker) and hang a “Work in progress – do not switch on” sign. Test your instrument on a live source, measure at the fitting's terminal block (line–neutral, line–fitting body), then test the instrument again. Simply turning off the light switch is not enough: in many homes the switch breaks the neutral by mistake, so line voltage still reaches the fitting.
Step 2. Remove the old tube and store it properly
Rotate the tube a quarter turn and pull it out gently; do not bend or knock it. The tube contains a small amount of mercury: keep it intact and store it in a box.
Step 3. Take photos and identify the supply wires
Photograph all the wiring before disconnecting anything. Find the terminal block where the supply enters the fitting and identify the line (via the switch), neutral and earth (if present). Do not trust wire colours in old houses.
Step 4. Remove the ballast and starter
Disconnect the wires from the ballast to the lampholders and terminal block, remove the screws and take out the ballast; remove the starter and the starter holder.
An electronic ballast must also be removed completely: if left in place, the tube receives power from the ballast output instead of the mains, which easily causes flickering, a damaged tube or a burnt-out ballast.
Do not leave exposed wire ends inside the fitting; cut off surplus wires or insulate each end fully.
Step 5. Read the diagram on the tube and identify which pins take line and which take neutral
This is the decisive step. Read the tube or box: single-ended or double-ended supply, which end is powered, which pin connects to L and which to N. If the diagram is unclear or contradicts the box: stop, do not guess; ask the seller or exchange it for a tube with a clear diagram.
Step 6. Rewire the fitting for the tube type
For a single-ended tube:
Choose one end of the fitting as the powered end (usually the one near the supply terminal block).
Connect the line (via the switch) to one contact of the lampholder at that end and the neutral to the other contact of the same lampholder, exactly as shown on the tube diagram.
The lampholder at the other end is not connected to power (unless the manufacturer says otherwise).
The two contacts of the powered lampholder must be separate from each other. Some lampholders (common in American-style fittings) connect the two contacts together internally; these must be replaced with standard lampholders.
For a double-ended tube:
Line to the lampholder at end A, neutral to the lampholder at end B; whether one pin or both pins are connected at each end follows the manufacturer's diagram.
Never put line and neutral into the same end.
For both types:
Join wires with lever connectors or correctly sized terminal strips (see how to join electrical wires properly); route wires neatly, away from sharp sheet-metal edges, and do not trap them under the cover.
Metal fittings: connect the earth wire (green/yellow) to the earth screw on the fitting if the circuit has an earth conductor.
The switch must break the line conductor; if it is breaking the neutral, tell the customer and correct it at the switch.
Step 7. Label the converted fitting
Years later, someone else may put a fluorescent tube or a different type of LED tube back in. Attach a durable label near the lampholder:
“Converted fitting – direct wire 220 V – ballast and starter removed.”
“Only fit direct-wire LED tubes, single-ended / double-ended supply.” (state the correct type)
“DO NOT fit fluorescent tubes.”
For single-ended tubes: mark the powered end of the fitting.
Step 8. Check before switching on and test the light
Before fitting the tube, disconnect the supply wires from the terminal block (so you don't measure through other lights on the same circuit), and use the multimeter's continuity range between the line and neutral wires on the fitting side: there must be no continuity. Measure each wire to the fitting body: there must be no continuity. For single-ended tubes: the two contacts of the powered lampholder must not be connected to each other.
Refit the cover, insert the tube and rotate it a quarter turn until it locks firmly; for single-ended tubes, the powered end must face the wired lampholder.
Switch on the breaker and the light switch: the light should come on instantly and evenly without flickering.
Turn off the switch and use the voltage tester to confirm that the wire to the light no longer carries line voltage. Let the light run for a while, then switch off and check whether the tube ends or connections are unusually hot.
Real-life situations
Situation 1: a rented room with 6 single fittings; one trips the breaker after conversion
The batch of “direct wire” tubes was the double-ended type; 5 fittings worked fine, but the 6th fitting had been wired out of habit as single-ended (line and neutral to the same lampholder), and the two pins at that end were connected internally, so it shorted as soon as the power was switched on.
Fix: switch off, rewire with line at one end and neutral at the other; replace the tube that suffered the short; carry out a continuity check before switching on; label all 6 fittings.
Situation 2: a shop with twin fittings on electronic ballasts; the LED tubes keep flickering
The customer had put “direct wire” tubes into twin fittings that still had their electronic ballasts; the lights flickered on and off and one tube had blackened ends. Fix: switch off, remove the ballasts, rewire both pairs of lampholders according to the tube diagram, replace the damaged tube and label the fittings.
Common faults and how to fix them
Symptom | Common cause | Fix |
|---|---|---|
Does not light | Single-ended tube fitted the wrong way round; not rotated to lock; ballast-type tube without an LED starter; single-ended/double-ended confusion | Check tube orientation and lampholders; compare the tube diagram with the fitting's wiring |
Breaker trips, short circuit at switch-on | L and N into the same end of a double-ended tube; lampholder with internally connected contacts; wire touching the body | Continuity test, rewire, replace the lampholder; replace any tube that has been shorted |
Dim, flickering | Electronic ballast still present with a direct-wire tube; incompatible ballast; poor lampholder contact | Remove the ballast and wire directly; clean or replace the lampholder |
Still glows dimly when switched off | Switch breaks the neutral; induced voltage on long cable runs | See the lesson LED lights still glowing dimly after switching off |
Burnt tube, blackened ends, burning smell | 220 V wired directly to a ballast-only tube; direct-wire tube in a fitting that still has a ballast; fluorescent tube in a fitting already converted to direct wire | Identify the correct tube type and wiring, replace the tube, label the fitting |
If the breaker keeps tripping and you have not found the fault, see also the procedure for finding why a circuit breaker keeps tripping.
Safety with old fluorescent tubes containing mercury
Do not smash tubes to make them easier to dispose of; do not snap them in half or burn them.
Keep tubes intact in a box or wrapped in paper, label them “broken fluorescent tubes”, keep them separate from household waste, and take them to a hazardous waste collection point or a take-back programme (ask your local waste collection service).
If one breaks: get people and pets out of the room, open windows to ventilate for a while before cleaning up (for reference: about 10–15 minutes), and switch off the air conditioner. Wear gloves, scoop up the pieces with stiff card, pick up fine fragments with sticky tape and put everything in a sealed bag or jar. Do not use a vacuum cleaner or a broom, because they spread the dust.
Safety checklist
Breaker switched off and sign hung; absence of voltage confirmed by measurement with an instrument tested on a live source.
Diagram on the actual tube to be fitted read: ballast type, single-ended or double-ended supply.
Direct-wire tubes: ballast (magnetic or electronic) and starter completely removed, with no exposed wire ends left.
Single-ended: L and N on the two separate contacts of the same lampholder. Double-ended: L at one end, N at the other.
Secure connections, switch breaks the line conductor, no continuity between line and neutral and no contact with the body.
Fitting labelled; old fluorescent tubes intact and packed separately for collection.
Large-scale lighting retrofits (factories, buildings) should be carried out by qualified electricians who meet the necessary requirements.
Working with customers on tube light conversions
Look at the fittings before the customer buys tubes; explain the three options (replace the starter, wire directly, replace with an LED fitting) so the customer can choose.
Agree on one tube type for the whole job and remind the customer to buy the type shown on the fitting label in future.
Clearly state the labour per fitting, materials and any extra costs if lampholders or wires have to be replaced. See also how to quote and work with customers.
Frequently asked questions
Do I need to remove the ballast when switching to LED tubes?
It depends on the type. Tubes designed for magnetic ballasts keep the ballast and only need the starter replaced with an LED starter; direct-wire 220 V tubes require the ballast and starter to be removed.
Can I fit a direct-wire LED tube into a fitting that still has an electronic ballast?
No. The electronic ballast must be removed completely. Only tubes that the manufacturer clearly states are compatible with that specific ballast may be fitted with the ballast left in place.
How do I know whether an LED tube is single-ended or double-ended?
Look at the diagram printed on the tube or box: single-ended tubes have L and N at the same end, usually with a marking for the powered end; double-ended tubes have L at one end and N at the other. If unsure, ask the seller — do not guess.
Can a fitting that has been converted to direct wire take a fluorescent tube again?
No. A fluorescent tube needs a ballast to limit the current; inserting one into a direct-wire fitting can burn the filaments, cause flashing or break the tube. To go back, you must reinstall the ballast and starter according to the original diagram.
Can a T8 LED tube be fitted into a T10 fitting?
T8 and T10 tubes have different diameters but usually the same G13 base, so tubes of the same length usually fit; what matters is still the wiring type. T5 tubes use a G5 base and cannot be swapped into a T8 fitting.
Practice exercises
Work on a practice bench with loose fittings that are not energised while you wire them; only switch on for testing on a board with a breaker and RCD under instructor supervision.
Exercise 1 – Identification: with 3 fittings (magnetic ballast, electronic ballast, integrated LED fitting) and 3 different LED tubes, identify what each fitting uses, read the tube diagrams and draw the wiring diagram before and after conversion.
Exercise 2 – Converting a fitting: remove the ballast and starter from a single fitting and rewire it for a single-ended tube; carry out a continuity test and label it; the instructor checks it before switching on for a test.
Exercise 3 – Fault finding: the instructor prepares a fitting with a fault (line and neutral into the same end for a double-ended tube, or an electronic ballast left in place). Using only your eyes and a multimeter, with the fitting de-energised, find the fault and explain what would happen if it were switched on.
Pass criteria:
No wire touched before the power has been switched off and confirmed dead by measurement.
Wired exactly according to the diagram printed on the tube, with no ballast, starter or exposed wire ends left; continuity test carried out in the correct order; fitting labelled.
Old fluorescent tubes packed correctly.
Related lessons to study next: installing recessed LED downlights: calculating the number of lights, layout and switch grouping and installing two-way switches and earthed sockets correctly.