NAMBINRoadmaps
Tools

Water pump & supply pipe sizing

For 1–6 floor houses: get the pump head, flow, pump power and main PPR pipe size. Use it to buy materials and check quotes — it does not replace a design drawing.

1. Supply method

2. The house

m

~150 L/person/day

m

From the pump down to the water in the ground tank/well

3. Water fixtures (whole house)

Result

Head needed
16.4 m
Lift height 11.4 m
Flow
0.4 m³/h
Fills 750 L in ~2 hours
Pump
125 W
Calculated ~34 W
Main PPR pipe
Ø32
Bore ≥ 19.5 mm

The roof tank should hold one day of water: about 1,000 L. Branches to each floor and pipes to the taps are usually PPR Ø20–Ø25.

Electrical safety: a pump is always wet — run the supply cable in conduit, earth it and fit a 30 mA RCBO. Never run a pump before priming it, or the seal burns out.

Learn more

Want to plumb a townhouse yourself?The Plumber roadmap: PPR pipe welding, pressure tests, pumps, roof tanks, water heaters, quoting.

Method: peak flow q = 0.2·√N L/s (N = total fixture units, TCVN 4513 style); head = lift height + suction + losses (~20%, at least 3 m) + 10 m residual pressure for a direct booster; power = ρ·g·Q·H ÷ 50% efficiency; pipe sized for ≤ 1.5 m/s at the PPR PN20 bore.

NAMBIN

NAMBIN — free step-by-step roadmaps for electricians, plumbers and spa technicians. Lessons written by working tradespeople, made for phones.

For learning only. Work on mains electricity, gas or pressurised water must be checked by a qualified person. © 2026 NAMBIN