Clients who call usually describe one of three things: in the middle of the night, with nobody using water, the pump starts by itself for a while every few minutes; as soon as the shower is turned on the pump keeps switching on and off and the flow surges between strong and weak; or the pump runs on and on without stopping and the body gets very hot. Each of these has a very different cause, and replacing the pump usually doesn't cure the problem.
The pump only obeys its controller, and the controller only looks at pressure or flow, so you have to narrow down the whole system using a pressure gauge and valve-closing tests. This lesson belongs to the "Pumps, water tanks & water heaters" step. By the end of this lesson, you will be able to tell whether the pump is running because of a leak, a leaking check valve, a pressure tank that has lost its air or has a ruptured diaphragm, a pressure switch that is wrongly adjusted or faulty, or a lack of water at the suction side, and deal with each case safely.
Safety before you start
Isolate the power before opening any cover: switch off the circuit breaker (MCB) supplying the pump before opening the pressure switch cover, capacitor box or controller; inside are terminals carrying mains voltage. Double-check with a voltage tester pen or multimeter.
Dry hands, dry footing: pump locations are often damp. Dry the floor and never work with wet hands or feet.
Earthing and shock protection: the pump body must be earthed, and the supply circuit should have a residual current device (ELCB/RCD). If pressing the test button doesn't trip it, or the pump body is live: stop and have an electrician sort it out first.
Release the pressure before removing pipework: the discharge side and the pressure tank still hold pressure after the pump has stopped. Isolate the power, close the valves and open the nearest tap to bring the pressure down to 0 before removing unions, gauges or the pressure switch.
Never let the pump run dry: before any test that involves closing the suction valve, switch off the pump. A pump running without water heats up very quickly and easily damages the seal and impeller.
Never disable protection: don't bypass the pressure switch, and don't remove dry-run or thermal protection "to keep the pump running".
Understand the system before diagnosing
Systems with a mechanical pressure switch and pressure tank
When the pressure in the pipe falls to the cut-in pressure, the pressure switch contacts close and the pump runs; when the pressure rises to the cut-out pressure, the contacts open and the pump stops. The gap between them is called the differential. A pressure tank has a rubber diaphragm or bladder dividing it into two chambers: an air chamber pre-charged with air pressure, and a water chamber. When the pump runs, water compresses the air; when water is used, the air pushes the water out. Thanks to this "air cushion", each pump run lasts long enough. If the tank loses its air, the pressure rises and falls very quickly and the pump cycles on and off constantly. Old-style steel pressure vessels without a diaphragm (as in the cover photo) gradually lose air into the water; the vessel becomes "waterlogged" and must be recharged with air according to the manufacturer's instructions.

Figure 1. Schematic of a pumped water supply system (labels in English): the pressure switch turns power to the water pump on and off according to the pressure in the pipe, and the pressure tank is connected to the water supply line. A booster pump drawing from a storage tank works on the same principle. (Drawing: PAR, Wikimedia Commons, CC0)
Electronic systems using a flow sensor
Many small pumps are sold as "electronic booster pumps": the controller has a flow switch and a pressure sensor. The general principle: open a tap, the pressure drops or flow is detected and the pump runs; close all taps, flow returns to 0 and the pump stops after a few seconds. Many controllers have dry-run protection: if no flow is detected for a while, the pump stops and shows an error.
Three symptoms, three directions for narrowing down
Starts periodically when nobody is using water: almost certainly water is escaping somewhere, either leaking out or flowing back to the source through the check valve.
Rapid on-off cycling and "surging" while water is being used: usually a pressure tank that has lost its air or has a ruptured diaphragm, or a pressure switch differential set too narrow.
Runs non-stop without cutting out: the pressure never reaches cut-out (lack of water, air being drawn in, cut-out set too high), or the controller is faulty (welded contacts, stuck sensor).
Tools to bring: a temporary water pressure gauge (many pumps don't have one fitted), a tyre pressure gauge and hand pump, a voltage tester pen, a multimeter, insulated tools and PTFE tape.
The 7-step procedure for finding the cause
Step 1. Ask the client and observe one cycle
Ask: when did the problem start, did it start after a water cut-off or pipe repair; is the water drawn from a roof tank, an underground tank or a well? Then close all taps and observe a few cycles: how long the pump runs, how long it rests, at what gauge reading it cuts out and at what reading it cuts in.
If the pump runs on and on, the body becomes very hot and then it switches off by itself, rests for a while and starts again, this may be the motor's thermal protection tripping and resetting when it cools, not the pressure switch. See Step 7.
Step 2. The valve-closing test: separate the house side from the pump side
Close all taps and wait for the pump to reach cut-out and stop.
Switch off the pump's circuit breaker so the pump can't restart during the test.
Close the discharge valve, where the pipe goes from the pump assembly into the house (after the pressure tank and gauge).
Watch the gauge for longer than one on-off cycle as recorded in Step 1.
The gauge holds steady: the pump assembly is sealed and water is being lost inside the house; go to Step 3. The gauge still drops: water is being lost at the pump assembly itself; go to Step 4. If there is no discharge valve, advise the client to have one fitted.
Step 3. Find where water is being lost inside the house
Toilet cistern: a flush valve that doesn't seal, or a float set too high so water runs through the overflow. Add food colouring to the cistern and wait without flushing; if colour appears in the bowl, the cistern is leaking (the repair is covered in the lesson on a toilet that runs constantly).
Float valve on an auxiliary tank: if the pump feeds a tank with a float valve and the float sticks, water flows non-stop.
Water heater safety valve dripping continuously: check the valve and the pressure; never plug the valve's drain pipe.
Taps, flexible connectors, angle valves leaking at the threads: go round with a torch and feel the bottom of the vanity cabinet and around the washing machine.
Leaks inside walls, under floors or in outdoor pipes: close each branch in turn to narrow it down, following the procedure in the lesson on detecting concealed leaks in walls.
Note that a water purifier discharging waste water while it filters is normal.

Figure 2. A pipe rusted at a bend, with water collecting in drops underneath. According to the photographer, this well-water pipe was dripping when the photo was taken. A leak of this size is enough to make the pump restart by itself. (Photo: Shamrock Lee, Wikimedia Commons, CC BY 4.0)
Step 4. Check the check valve and the pump assembly
Pumps drawing from a tank usually have a check valve at the suction inlet or inside the pump body; well pumps have a foot valve. When the pump stops, the pressure on the discharge side is higher than on the suction side; if the valve doesn't seal, water flows back through the pump to the source, the pressure drops and the pump starts again.
Keep the pump breaker off (switch it on for one cycle to restore pressure, then switch off again) and also close the suction valve. If the gauge now holds steady, whereas with only the discharge closed it dropped: water is flowing back through the check valve. If it still drops with both sides closed: there is a leak within the assembly itself; check the pump seal (water weeping where the shaft passes between the motor and the pump chamber), threaded joints, and the tank and pressure switch connections.
Fix: release the pressure, remove the valve and check the valve disc, spring and gasket. Scale, sand or PTFE tape stuck on the seat is very common. If the valve is worn or the spring is weak, replace it with a valve of the same size, fitted in the direction of the arrow. If the seal is leaking, replace it with the correct part number or send the pump for warranty service.

Figure 3. A brass spring check valve; the arrow engraved on the body shows the direction of water flow. A valve that lets water back makes the pressure drop while the pump is resting; if fitted the wrong way round, water can't pass at all. (Photo: SilverBullet X, Wikimedia Commons, CC0)
Step 5. Check the pressure tank: lost air or ruptured diaphragm?
Signs: as soon as a tap is opened, the gauge falls quickly to cut-in, the pump runs for a few seconds and reaches cut-out, and this repeats continuously, with water coming out in surges.
Tap the tank body lightly: hollow at the top and solid at the bottom is normal; if the whole tank sounds solid, it may be full of water.
Press the air valve core lightly: only air coming out is normal; if water squirts out, the diaphragm or bladder has ruptured, and the bladder (if replaceable) or the tank must be replaced.
Measuring and recharging the air:
Switch off the pump circuit breaker.
Close the valve between the tank and the system (if fitted) or close the suction side, and open the nearest tap to drain all the water from the tank. The reading is only correct when the water chamber is empty; if there is still pressurised water, the tyre gauge will only read the system pressure.
Measure at the air valve, and pump in or let out air to the required level. Some pressure tank installation guides for pumps controlled by a pressure switch recommend setting the air pressure about 0.2 bar below the cut-in pressure (reference); electronic or variable-speed pumps have their own instructions. Always follow the manufacturer, and never exceed the maximum pressure on the tank label.
Close the tap, open the valve, switch on the breaker, and record the cut-in and cut-out pressures.
If the tank loses its air again a few weeks after recharging: test the air valve with soapy water, or the diaphragm may be starting to leak. If the tank is rusted through, dented or leaking at a weld, replace it; don't weld or patch it.

Figure 4. A wall-mounted diaphragm expansion vessel with an isolating valve and a small drain valve below the neck. According to the photographer, this valve set is used to check the air pressure once the vessel has been isolated and the water pressure released; a pump's pressure tank is measured on the same principle. (Photo: The RedBurn, Wikimedia Commons, CC BY-SA 4.0; label blurred)
Step 6. Check and adjust the controller
Mechanical pressure switch: compare the measured cut-in and cut-out pressures with the pump's instructions.
Cut-out set too high, close to or above the maximum pressure the pump can produce (see the performance curve in the manufacturer's documentation): the pump runs non-stop, especially when the supply weakens or the pump is worn.
Differential too narrow: the pump cycles frequently even though the tank is fine.
Pressure sensing port blocked with scale: the switch responds slowly or doesn't cut out; isolate the power, release the pressure, remove it and clean it.
Pitted or welded contacts: if welded, the pump runs on even though the pressure is already high. Replace the switch with one of the same pressure range and current rating.
Many mechanical pressure switches have two spring nuts: the large spring usually shifts both cut-in and cut-out, and the small spring usually adjusts the differential; the arrangement varies by manufacturer, so read the instructions. Procedure: switch off the breaker, open the cover, turn a little, close the cover, switch on, observe one cycle and repeat. Never adjust while live. If you change the cut-in pressure, readjust the tank air pressure as in Step 5.
Electronic controller: when there is a small leak, this type also restarts every time the pressure falls below its start threshold, so fix the leak first. If the system is sealed (Step 2) but the pump still runs non-stop, suspect a flow sensor stuck with scale or sand: isolate the power, release the pressure and clean it as the manufacturer instructs; if that doesn't work, replace the controller with the correct part number. If the pump cycles on and off continuously when a tap is opened only slightly, the flow may be below what the sensor can detect; open the tap further to test.

Figure 5. Inside an adjustable pressure switch: the pressure adjusting spring, a bar scale and two pointers, blue and red. The meaning of each pointer and the position of the adjusting screws vary by model; only open the cover and adjust once the breaker is off. (Photo: Sarah Adrita, Wikimedia Commons, CC BY-SA 4.0)
Step 7. Check the water source, suction line and overheating
Empty source tank or water level below the suction inlet: the pump draws air and runs dry. Also check the float valve feeding the tank.
Blocked suction strainer, Y-strainer or foot valve: the pump is "starved of water" and the pressure doesn't reach cut-out.
Air being drawn in: a leaking joint on the suction line doesn't drip water out but sucks air in; signs are air bubbles at the taps, unusual noise and loss of prime. Reseal the joints.
Re-prime the pump: isolate the power, open the priming plug, fill the pump chamber and suction line with water as the manufacturer instructs, tighten the plug, and only then run it.
Overheating: a hot enclosed location, long run times, a jammed impeller or a weak capacitor. If the pump hums but doesn't turn: isolate the power and pass it to an electrician to check.
If an electronic controller shows a dry-run error, only restart it when you are sure there is water at the suction inlet.
Quick reference table: symptom – likely cause – how to check – how to fix
Symptom | Likely cause | How to check | How to fix |
|---|---|---|---|
No water in use, but the pump still starts periodically | Leak inside the house: toilet cistern, float valve, taps, concealed leak | Close the discharge valve; the gauge holds steady | Find and repair the leak |
As above, but the gauge still drops with the discharge closed | Leaking check valve, leaking seal or joints in the pump assembly | Also close the suction; if the gauge holds, the valve is leaking | Clean or replace the valve; replace the seal, reseal joints |
Opening a tap makes the pump cycle rapidly, with surging flow | Pressure tank has lost air or has a ruptured diaphragm | Tap the tank, press the air valve, measure air pressure with the tank empty of water | Recharge air to the correct level; replace if the diaphragm has ruptured |
Pump cycles frequently even though the tank is fine | Differential too narrow | Compare cut-in and cut-out with the instructions | Readjust with the power off |
Runs non-stop, pressure stays below cut-out | Cut-out set too high, worn pump, blocked suction strainer | Compare the gauge with the pump performance curve | Reset to the instructions, clean the strainer |
Runs non-stop even though the pressure is already high | Welded contacts, stuck flow sensor | The gauge exceeds cut-out but the pump doesn't stop | Isolate immediately; clean or replace the controller |
Weak flow with air bubbles, pump hot | Empty tank, air leak, loss of prime | Check the source tank and suction line joints | Supply water, reseal, re-prime |
Gets hot, stops, then restarts by itself | Thermal protection operating | Feel the pump body, time how long it stays off | Find the cause of overload or dry running |
Reference table: pressure readings to record
The methods and examples below are for reference, following the manufacturer's instructions; the figures in the example column are not the specifications of any particular unit.
Parameter | How to determine it | Illustrative example (reference) | Notes |
|---|---|---|---|
Cut-in pressure | Gauge reading when the pump just starts | Say 1.5 bar | Per the pump and pressure switch instructions |
Cut-out pressure | Gauge reading when the pump just stops | Say 2.5 bar | Clearly lower than the pump's maximum pressure |
Differential | Cut-out minus cut-in | 1.0 bar | Too narrow causes frequent cycling |
Tank air pressure, pressure switch system | Measured at the air valve, pump off, tank empty of water | About 1.5 − 0.2 = 1.3 bar | About 0.2 bar below cut-in according to some tank documentation; follow the manufacturer |
Tank air pressure, electronic or variable-speed system | Per the pump documentation | Don't use the formula above | The manufacturer has its own specification |
Maximum pressure of the tank, pipes and appliances | Labels and documentation | Read from the label | Cut-out must not exceed it |
Conversions when reading gauges: 1 bar is approximately 14.5 psi and approximately 1 kgf/cm².
Real-life cases
Case 1: a townhouse drawing from a roof tank, with the pump starting by itself all night. Switch off the breaker and close the discharge: the gauge holds steady, so the leak is inside the house. Food colouring added to the upstairs toilet cistern ran into the bowl. Replace the flush valve seal and adjust the float; the pump no longer starts by itself.
Case 2: an apartment with a pump that has a small tank on its body; every time someone showers the pump goes "click-click". Pressing the air valve makes water squirt out: the bladder has ruptured. Replace the tank with one of the same capacity, setting the air pressure before fitting; the pump now runs smoothly.
Case 3: a pump drawing from an underground tank runs non-stop, the body is hot and the pressure stays below cut-out. The tank was nearly empty, and the pressure switch had also been turned up high. Isolate the power, wait for the tank to fill, re-prime, bring cut-out back to the recommended level and readjust the tank air pressure.
Safety and acceptance checklist
Switched off the breaker and proved dead before opening the pressure switch, capacitor box or controller; dry hands and dry footing.
The pump body is earthed; the circuit has residual current protection and the test button works.
Released the pressure before removing pipes, gauges, the pressure switch or the air valve.
Never ran the pump with the suction closed or the tank empty; fully primed before restarting.
Did not bypass the pressure switch or remove dry-run or thermal protection.
After repair: with all taps closed, the pump reaches cut-out and stops; with the breaker off, the gauge does not drop for longer than the old cycle time.
Recorded in the job report: cut-in pressure, cut-out pressure, tank air pressure with units, the cause and the parts replaced.
Call an electrician or the warranty service when: the pump body is live, the residual current device keeps tripping, the motor hums but doesn't turn, there is a burning smell, the capacitor needs replacing and you haven't been trained to do it, or the pump is still under warranty.
Frequently asked questions
Is it harmful if the pump starts by itself every few minutes?
Yes. Each start draws a higher current than steady running and the pressure switch contacts arc, so frequent cycling wears out the switch, capacitor and motor quickly. Manufacturers usually limit the number of starts per hour; see the pump documentation.
Does the pressure tank need recharging with air regularly?
A sealed diaphragm tank holds its air quite well but can still lose some through the air valve. Check it during maintenance as the manufacturer recommends, and straight away when the pump starts cycling more often.
Can the pressure tank be removed to save space?
Not for pumps controlled by a pressure switch: without a tank, the pressure rises and falls almost instantly, so the pump cycles constantly. For electronic pumps, keep the configuration the manufacturer specifies.
Can I turn the pressure switch up to get stronger water flow?
Only within the range in the instructions, and the cut-out must be clearly lower than the maximum pressure the pump can produce and the pressure rating of the pipes, water heater and appliances. If you overdo it, the pump runs non-stop or the appliances are subjected to high pressure. If you change the cut-in, readjust the tank air pressure.
Practical exercise
Draw a diagram of a real pump assembly, marking the valves on both sides, the check valve, the tank, the pressure switch and the gauge.
On a system that is working well, record the cut-in and cut-out pressures and the duration of one cycle with one particular tap open, as a baseline for comparison.
Under the guidance of a master plumber, carry out the tests in Step 2 and Step 4 (with the pump breaker off) and explain the results.
Measure and recharge the air pressure of a pressure tank that has been fully drained, following the manufacturer's instructions.
Self-assessment criteria — you pass when:
You always switch off the breaker, prove dead and release the pressure before opening the pressure switch or removing pipes; you never let the pump run dry.
You can distinguish the three symptoms and use the valve-closing test to tell whether water is being lost inside the house or at the pump assembly.
You can check whether the tank has lost air or has a ruptured diaphragm, and adjust the air pressure and pressure switch according to the manufacturer's instructions.
You carry out the final acceptance check with a pressure gauge and explain the cause to the client.
For new installations, fit isolating valves on both sides, a check valve, a pressure gauge and a pressure tank so that diagnosis is easier later on.