"Could you come and install the RO purifier I just bought, under the kitchen sink?" It sounds simple, but many jobs end in a call-back because a push-fit connector weeps and floods the kitchen cabinet, a wrongly connected drain line makes the sink smell, or the unit runs all night without shutting off. Most of these faults are created during the installation itself and can be avoided by following the right sequence.
This lesson is for people who already know how to use a spanner and wrap PTFE tape, and focuses on household RO water purifiers installed under the kitchen sink (under-cabinet units, with or without a pressure tank). By the end of this lesson, you will be able to survey the site, tap the water supply, connect the drain in the right place, fit a dedicated faucet, make push-fit connections watertight, flush the filters, measure TDS and hand the unit over.
Each manufacturer has its own diagram, pressure limits, inlet water temperature limits and filter flushing procedure: the manual supplied with the unit always takes priority over this lesson.
Safety before you start
An under-cabinet RO unit involves pressurized water and electricity (pump, adapter) in a cramped space. Before you begin:
Shut off the water before cutting or disconnecting anything: close the angle valve feeding the kitchen faucet or the apartment’s main valve, and open the kitchen faucet to release all pressure in the pipes. Have a bowl and rags ready under the work area.
Do not plug the unit in until all connections are made and leak-tested: if the pump runs while connections are still open, it can spray water onto the adapter and the socket.
A socket inside the kitchen cabinet is the electrician’s job if there isn’t one already: do not run an extension lead yourself, and do not leave a socket or adapter lying on the floor of the cabinet where water can collect. The kitchen socket circuit should have residual current protection (RCD/ELCB); if the house has none, note it on the job sheet and tell the client.
Drilling the sink or stone countertop: wear safety glasses and gloves; stainless steel edges are very sharp after drilling.
Never connect the RO unit to the hot water line: hot water can damage the filters and membrane. The inlet water temperature limit is given in each unit’s manual.
Do not remove, shorten or omit the drain flow restrictor (flow-restrictor valve on the waste line): it maintains the pressure the membrane needs to work; without it the unit produces poor water and the membrane fails quickly.
Understand how water flows through an RO unit before installing it
A household RO unit usually has the following assemblies (names and number of stages vary by manufacturer):
Pre-treatment filters (usually a PP sediment cartridge and an activated carbon cartridge): they trap sediment and reduce chlorine to protect the membrane. New carbon cartridges usually release black carbon dust at first and need flushing.
Pump and solenoid valve (on pumped units): the pump pushes water through the membrane; the solenoid valve closes the supply when the unit is idle.
RO membrane: lets only part of the water through as purified water (clean water going to the faucet), while the rest carries the dissolved substances out through the waste line. Every RO unit produces waste water; the waste ratio depends on the unit’s design, the pressure and the quality of the source water.
Flow restrictor: a small restriction on the waste line that creates pressure for the membrane.
Pressure tank (if fitted): stores purified water so the faucet flows strongly; direct-flow units have no tank.
Low-pressure switch, high-pressure switch, check valve: switch the pump off when the source water fails or the tank is full, and prevent water flowing backwards.
Post-membrane filters (post-carbon, mineral cartridge, etc. depending on the unit), followed by the dedicated RO faucet.

Figure 1. A large spiral-wound RO membrane element cut open: many layers of white membrane alternate with spacer mesh, wound around a central tube. The membranes in household units are smaller but use the same spiral design. (Photo: David Shankbone, Wikimedia Commons, CC BY 3.0)
Most cases of a "faulty unit" right after installation come from connecting to the wrong port: the feed line plugged into the waste port, or the waste line plugged into the faucet outlet. The unit’s body usually has labels for each port; read the labels and the diagram before cutting any tubing.
The 7-step procedure for installing an under-sink RO purifier
Step 1. Survey the site and agree with the client before opening the box
Ask and check:
Water source: mains water, well water or water from a rooftop tank? Well water with alum, iron or limestone usually needs whole-house pre-filtration first; if the RO is connected directly, the filters and membrane can clog very quickly. When the water quality is in doubt, advise the client to have the water tested; never promise on your own that "after filtering, it’s all drinkable".
Water pressure at the kitchen: too weak (houses fed from a rooftop tank, top floors) or too strong (with a booster pump)? Temporarily attach a pressure gauge to the faucet to get a real figure and compare it with the inlet pressure range in the manual; if the pressure exceeds the limit, a pressure-reducing valve is needed.
Cabinet space: measure the inside of the cabinet, minus the trap; is there room for the pressure tank and for changing the filters later?
Power socket: is there a socket inside or near the cabinet, in a dry position above the cabinet floor?
RO faucet location: does the sink have a pre-cut hole, and can the countertop be drilled?
Photograph the cabinet before you start and tell the client clearly about any problems (no socket, pressure too high, untreated well water) before starting.
Step 2. Test-position the unit and plan the tubing routes
Place the unit in the cabinet (not yet connected) to make sure it stands steadily, does not press on the sink waste pipe or trap, does not block the angle valves, and leaves space at the front to remove the filters when changing them. Stand the pressure tank (if fitted) upright close to the unit. Route the power cord up to the socket without passing through places where water can collect.
Plan the routes for four lines: feed water, waste water, outlet to the faucet and tank line. Keep the tubing neat with wide bends and no kinks, leaving just enough slack to pull the unit out when changing filters.
Step 3. Tap the supply: a diverter valve on the cold water line
The RO unit takes water from the cold water line feeding the kitchen faucet. The common method:
Close the cold-water angle valve for the kitchen faucet and disconnect the flexible supply hose from the angle valve.
Fit the diverter valve (feed valve) supplied with the unit: usually a threaded tee with a small branch and its own shut-off valve for the purifier. Some units use a dual-outlet angle valve to replace the existing angle valve. Choose the one with the right thread size for the client’s angle valve.
Reconnect the kitchen faucet supply hose to the tee and push the purifier feed line into the small branch.
Thread-sealing technique:
Wrap PTFE tape in the tightening direction: looking straight at the end of the male thread, wrap clockwise (for a normal right-hand thread); the number of turns depends on how loose the thread is. Wrapped the wrong way, the tape gets stripped off as you screw it in.
Do not put PTFE tape on ends that seal with a flat rubber washer: those joints seal with the washer, and tape squeezed in between actually causes leaks.
Tighten plastic threads hand-firm only: over-tightening can crack the base of the thread, and a cracked joint usually does not leak immediately but starts leaking a few days later.
Use two spanners: one to hold the angle valve body and one to turn the tee, so you do not twist the pipe inside the wall.

Figure 2. A new brass shut-off valve with a round handle, its threaded ends wrapped in white PTFE tape before installation under the kitchen sink. When wrapping it yourself, do not let the tape protrude into the bore of the pipe. (Photo: Tomwsulcer, Wikimedia Commons, CC0)
A common mistake: tapping the hot water line by mistake because the two angle valves sit side by side. Before disconnecting, open the kitchen faucet on the hot and cold sides in turn to identify the cold-water angle valve correctly.
Step 4. Connect the waste line in the right place
Use the drain saddle clamp supplied with the unit, clamped onto the sink waste pipe on the section before the trap (i.e. above it, between the bottom of the sink and the water seal). This way the trap still blocks sewer odours, and the RO waste water passes through the trap just like dishwashing water.
Drill the hole in the top or side of the pipe, never in the bottom: a hole in the bottom is easily blocked by sediment and food scraps, and dirty water can easily flow back into the waste line.
Drill the hole to the correct size for the drain saddle, remove all burrs, position the gasket correctly and only then tighten.
Run the waste line with a downward slope, with no dip lower than the connection point and without being crushed.
Never connect the waste line directly to the pipe after the trap or to a stack with no trap, because sewer odours can come back up.
Some RO faucets have a built-in air gap (anti-backflow gap); if the unit uses this type of faucet, route the waste line according to the manufacturer’s diagram.
Step 5. Drill the hole and fit the dedicated RO faucet
The RO faucet only delivers purified water. If the sink has a pre-cut hole of the right size, use it; if you have to drill:
Choose the position: clear of the kitchen faucet, with nothing underneath touching the cabinet walls, and with room to tighten the nut.
Stainless steel sinks: mark the centre with a centre punch, drill a small pilot hole, then drill or cut the hole to the size given in the faucet instructions. Drill at low speed with even pressure, add a few drops of cutting oil to cool it, and file off the burrs. Wipe away all metal swarf so it does not rust and leave stains on the sink.
Stone countertops: use a drill bit made for that type of stone and drill slowly with water cooling. Natural and engineered stone can crack if drilled incorrectly; if you are not sure, explain the risk to the client clearly or use an existing pre-cut hole.
Fit the faucet: gasket on top of the sink, gasket/washer underneath, and tighten the nut until the faucet stands firmly without turning.
Step 6. Cut the tubing and make push-fit connections watertight
The water lines in household RO units are usually flexible plastic (PE) tubing pushed into push-fit connectors. The most common size is 1/4 inch; some units use a larger size for the feed line or the tank; use the connector size of your unit. Most leaks under the sink start here.
Cut the tubing square with a tube cutter or a sharp knife. Do not use cutting pliers: they squash the end of the tube, so the O-ring in the connector does not seal around it.
Check the tube end: round, with no lengthwise scratches and no burrs. If the end is scratched, cut off a length.
Push in to the full depth: push the tubing in until it hits the internal stop. Mark the tubing with a pen before inserting so you know it has gone in far enough.
Fit the locking clip if the connector has one, so the release collet cannot be pressed accidentally.
Pull test: correctly inserted tubing will not pull out.
To disconnect: shut off the water, release the pressure, press the release collet down evenly and pull the tubing out.
Connect all the lines according to the diagram, then check each line against the labels on the unit once more before turning on the water.

Figure 3. A white mesh-wrapped activated carbon filter cartridge with blue end caps, next to a clear filter housing with a blue cap; the tape measure on the left shows the cartridge is about 25 cm long. When fitting or replacing housing-type cartridges, check that the housing O-ring sits correctly in its groove before screwing it closed. (Photo: Cschirp, Wikimedia Commons, CC BY-SA 3.0; product label blurred)
Step 7. Turn on the water, leak-test, connect power, flush the filters and test
Follow the sequence; do not skip steps:
Pressure tank (if fitted): before connecting it, check the tank’s air pressure while it is empty using a pressure gauge on the air valve, and compare it with the figure given by the manufacturer. Close the tank valve while flushing the filters if the manual requires it.
Open the diverter valve slowly, with the unit still unplugged. Water enters the first filter housings; look at and feel every connector and every threaded joint. If you see a weep, shut off the water and fix it immediately.
Wrap dry tissue paper around each connector and place a sheet under the unit: wet paper reveals leaks more clearly than your eyes.
Plug in the power and let the unit run. Listen for the pump and check that water is flowing out through the waste line (listen or look at the waste pipe).
Flush the filters according to the manufacturer’s instructions: usually you open the RO faucet and let water run for a while to flush out carbon dust and air bubbles; many manufacturers recommend discarding the first purified water (for example the first full tank; refer to the manual). Milky-white water caused by air bubbles clears after a few minutes; black water with carbon particles needs more flushing.
Check automatic shut-off when full (units with a pressure tank): close the RO faucet and wait for the tank to fill. The unit must stop the pump and the waste water must stop flowing. If the waste keeps flowing after the tank is full, the unit is wasting water; check the shut-off valve, solenoid valve and check valve.
Measure the TDS of the feed water and the output water and record them on the job sheet (see the reference table below).
Check the sheets of paper again after the unit has run for at least several tens of minutes, and tell the client to check under the cabinet again after one day.

Figure 4. A white handheld TDS meter pen with a display and three buttons, ON/OFF, TEMP and HOLD; the probe’s protective cap has been removed and placed beside it. (Photo: Morn, Wikimedia Commons, CC BY-SA 3.0)
Reference table: parameters to measure and record during installation
Parameter | How to measure or determine it | Illustrative example | Notes |
|---|---|---|---|
Water pressure at the kitchen | Temporarily attach a pressure gauge to the faucet, with other taps closed | Record the actual reading | Compare with the inlet pressure range in the unit’s manual |
Source water TDS | TDS pen, water from the kitchen faucet | Say 300 ppm (assumed figure) | For comparison only, not a safety indicator |
Purified water TDS | TDS pen, water from the RO faucet after flushing the filters | Say 20 ppm (assumed figure) | Units with a post-membrane mineral cartridge give a higher reading |
Rejection rate (estimated) | (TDS in − TDS out) ÷ TDS in × 100 | (300 − 20) ÷ 300 × 100 ≈ 93% | Reference; compare with the manufacturer’s published specification |
Pressure tank air pressure when empty | Pressure gauge on the tank’s air valve | See the tank label | Wrong pressure means weak faucet flow and low storage |
Purified water and waste water flow | Collect in a measuring jug for 1 minute | Record the actual reading | Used for comparison at the next service |
Installation date, filter types | Write on a sticker on the unit | 27/10/2026 | Reference point for filter changes |
A note when talking to the client: a TDS pen only estimates total dissolved solids through electrical conductivity; it does not tell you whether the water contains bacteria and cannot detect many other substances. Never say "low TDS means the water is completely safe".
Quick reference table: common faults right after installation
Symptom | Likely cause | How to check | What to do |
|---|---|---|---|
Water weeping at a push-fit connector | Tube not cut square, tube squashed by pliers, not fully inserted | Pull the tube out and inspect the end; compare with the pen mark | Recut square, push in fully, fit the locking clip |
The sink smells after installation | Waste connected after the trap, drain saddle not sealing | Follow the waste line to its connection point | Move the connection to before the trap, replace the saddle gasket |
Waste water keeps flowing when the tank is full | Shut-off valve, solenoid valve or check valve not working | Close the faucet, wait for the tank to fill, listen to the waste line | Check against the manufacturer’s diagram, replace the faulty part |
Pump keeps starting and stopping | Fluctuating supply pressure, wrong tank air pressure, a leak downstream | Measure supply pressure, check tank pressure, look for leaks | Fix the water supply, adjust the tank pressure, repair the leak |
RO faucet gives very little or no water | Diverter or tank valve not opened, wrong port connected, low supply pressure | Trace each line against the diagram | Connect to the correct ports, open the valves, deal with the supply pressure |
Real-life scenarios
Scenario 1: the kitchen cabinet floods after two days
A plumber installs an RO unit, sees that it is watertight during testing and leaves. Two days later, the cabinet’s bottom panel has swollen with water. The feed line had been cut with pliers, leaving the tube end slightly flattened; it did not weep during the test, but at night, when few people use water, the line pressure is higher and water began to seep out. The fix: recut the tube end with a knife, push it in to the full depth, fit the locking clip, place a drip tray under the unit and tell the client to check the cabinet after one day.
Scenario 2: "the kitchen sink has smelled since the purifier was installed"
The previous plumber had drilled the drain saddle into the section of pipe after the trap, close to where the pipe enters the wall. That section connects directly to the sewer, so if the saddle is even slightly loose, odours escape straight into the cabinet. The fix: replace the drilled section of pipe (or plug the hole with a suitable fitting) and reconnect the drain saddle on the section before the trap, with the hole in the side.
Safety and acceptance checklist
☐ The unit takes water from the cold line, with its own shut-off valve for the purifier.
☐ PTFE tape wrapped in the correct direction, not on joints that use washers; plastic threads not over-tightened.
☐ Drain saddle before the trap, with the hole in the top or side; the waste line does not sag.
☐ The flow restrictor is intact and the correct type for the unit.
☐ Every push-fit connector: tube cut square, fully inserted, locking clip fitted, pull-tested without coming out.
☐ Socket and adapter in a dry place above the cabinet floor; no makeshift extension leads.
☐ Filters flushed according to the manual, and the water runs clear.
☐ The unit shuts off when the tank is full and the waste water stops (units with a pressure tank).
☐ Feed and output TDS, installation date and filter types recorded on the job sheet and the sticker.
☐ The test paper under the connectors is still dry after the test-run period.
Handover and advice to the client
Show the client in person the unit’s own shut-off valve: if they see a leak under the cabinet, close it immediately and unplug the unit.
Explain why an RO unit always produces waste water, so the client does not think the unit is broken when they hear water running into the waste pipe.
Filter replacement schedule according to the manual and the actual water quality; do not promise one fixed interval for every household.
When away for a long time: close the feed valve and unplug the unit; on returning, discard the stagnant water according to the manufacturer’s instructions.
Frequently asked questions
Can an RO purifier be connected to the hot water line or to water from the water heater?
No. The filters and membrane of household RO units are designed for cold water; hot water can damage them. The inlet water temperature limit is given in the manual.
Can the RO waste water be reused?
RO waste water contains more dissolved substances than the source water and must not be used for drinking or cooking. Some households collect it for mopping floors or flushing toilets. If the client wants to collect it, the waste line must run into a container with an overflow back to the drain, and the end of the waste line must not be submerged in the container (to prevent dirty water being siphoned back into the line).
What TDS reading after filtering counts as acceptable?
There is no universal figure: units with a remineralizing cartridge give a higher TDS than units without one. Compare with the manufacturer’s specification and the reading taken at installation; a clear drop in rejection rate over time is a sign that the membrane and filters need checking.
Practice exercises
On a sample RO unit in the workshop (not plugged in), read the labels and identify all the ports: feed water, waste water, faucet outlet, pressure tank; draw the water flow diagram by hand.
Practise cutting 10 lengths of PE tubing with a tube cutter, pushing them into push-fit connectors, marking the depth, fitting locking clips and pull-testing; then disconnect them correctly without scratching the tubing.
On a sample sink waste assembly, fit a drain saddle before the trap and explain why it must not be connected after the trap.
Attach a pressure gauge to a tap and record the pressure; measure the TDS of tap water and a sample of purified water, and calculate the rejection rate using the formula in the table.
Self-assessment criteria — you pass when you:
Always shut off the water and release the pressure before disconnecting, and only plug in the unit after leak-testing.
Tap the correct cold line and connect the waste in the correct position before the trap.
The unit shuts off correctly when the tank is full and the waste water stops flowing.
Can explain the waste water, TDS and filter replacement schedule to the client without over-promising.