New plumbers working with a team often run into this: they arrive at a client’s home to fix a leaking tap, open the tool bag and only then discover there is no PTFE tape, the adjustable spanner will not open wide enough for the nut, and there is no bucket to catch the water, so it spills onto the wooden floor. A fifteen-minute job drags out to an hour, and the client sees all of it. Tools do not replace skill, but with missing or wrong tools even a skilled plumber struggles to work cleanly and quickly.
This lesson belongs to the first step of the residential plumber roadmap on NAMBIN: pipe materials, tools and job-site cleanliness. By the end of this lesson, you will be able to name the groups that make up a basic tool kit, explain what each item is for, use it correctly and safely, and decide what to buy first and what can wait. The lesson does not promote brands or prices; the tool sizes mentioned are for reference only, and you should always read the manufacturer’s instructions when buying and using them. If you cannot yet tell the different pipe types apart, read the lesson Telling PPR, uPVC and HDPE pipes apart first, because the choice of cutting and joining tools depends on the pipe type.
Think about tools by task, not by list
Instead of memorizing a long list, remember that a plumber’s working day involves six kinds of operation. Each one needs a group of tools:
Measuring, marking, checking level and slope: so pipes follow the right route at the right height and drains have a proper fall.
Cutting and preparing pipe ends: cut square and deburr cleanly so the joint seals.
Joining pipe: heat fusion welding (PPR), solvent cement (uPVC), PTFE tape for threaded joints.
Tightening and loosening threads and nuts: fitting taps, valves, supply hoses, traps and water meters.
Clearing blockages: dealing with blocked toilets, washbasins and floor drains.
Testing and safety: pressure testing, checking for electricity before touching pumps and water heaters; protective equipment; job-site cleaning supplies.
When getting ready for work, ask yourself: which of these six operations will I be doing today? If a group is missing, add it before you leave.

Figure 1. A standard adjustable spanner (flat-jaw adjustable wrench), 6 inch – 150 mm, with a worm screw to adjust the jaw opening and a scale on the jaw. This is the tool you need almost every time you tighten nuts on supply hoses, taps and valves. (Photo: Fructibus, Wikimedia Commons, CC0)
Group 1: Measuring, marking and checking
Tape measure (steel tape): measure pipe lengths, centre-to-centre distances between two stub-outs, and heights from the floor. Plumbers use a few-metre tape with a lock most of all.
Marker: an oil-based marker or carpenter’s pencil to mark cut positions and insertion depth on the pipe end before welding or gluing.
Spirit level: check that taps, basins, toilets and water heaters are level; check that drain pipes slope in the right direction. Drain pipes must fall towards the outlet; the exact slope comes from the design (see step 4 of the roadmap: drainage, slope and odour prevention).
Try square: mark a square cutting line around large pipes when you have no dedicated cutting tool.
Chalk line or laser level (if available): mark pipe routes on the wall before cutting chases.
Tip for accurate measuring: measure twice, cut once. When measuring a length of pipe between two fittings, remember to add the length of pipe that goes inside the fitting at both ends; forgetting this is the classic mistake that leaves a pipe too short.
Group 2: Cutting pipe and preparing pipe ends
Each pipe type has a suitable cutting tool. Using the wrong tool easily deforms, crushes or cracks the pipe end.
Plastic pipe cutter (shears): for small PPR, PE and uPVC pipes. The sharp blade cuts quickly and cleanly. Each cutter has a maximum pipe size marked on the body or packaging; do not force it on larger pipes, as this can shatter the pipe end or break the cutter. Hold the cutter square to the pipe.
Hacksaw (steel-framed hand saw): for large uPVC pipes (drain pipes), galvanized steel pipes, threaded rod and pipe hangers. Fit the blade with the teeth pointing forward: it cuts on the push stroke, so pull back lightly. Clamp the pipe firmly before sawing.
Wheel-type metal pipe cutter: for copper pipe, thin stainless steel pipe and small galvanized pipe: clamp it around the pipe, turn it a few times, tighten a little more, and repeat until the pipe is cut through. The cut is squarer and cleaner than with a saw.
Utility knife, deburring tool, file: remove burrs inside and outside after sawing. uPVC pipes need a chamfer on the end before gluing so the cement is not all scraped off when the pipe is pushed in (details in the lesson gluing uPVC pipe with solvent cement correctly).

Figure 2. A C-frame hacksaw with a plastic handle; the blade is fitted between two pins and tensioned with a wing nut at the end of the frame. The blade must be taut, with the teeth pointing forward. (Photo: Luke Milburn, Wikimedia Commons, CC BY 2.0; text on the handle blurred)
Safety when cutting: wear glasses when sawing and deburring (plastic and metal shavings can fly into your eyes); keep your hands out of the blade’s path; never cut a pipe while it is under water pressure – close the valve and release the pressure first.
Group 3: Pipe joining tools
Heat fusion welder (for PPR pipe)
A PPR welder consists of a heating plate and pairs of welding sockets (one heats the pipe, one heats the fitting) for each pipe size. Homes usually use small pipe sizes such as Ø20, Ø25 and Ø32 (reference, depending on the project), so your kit needs sockets for the sizes you meet most often. The working temperature, heating time and holding time for each pipe size come from the pipe and welder manufacturers’ tables; the lesson welding PPR pipe correctly explains in detail how to read those tables and the mistakes that cause leaking welds.
Notes when using the welder:
The welding sockets are very hot: always place the welder on its stand/holder, never directly on a wooden floor, mattress or packaging.
Plug it into a socket protected by a residual current device (RCD / earth-leakage breaker); keep the welder and its cable out of wet areas.
Fit and tighten the welding sockets while the welder is cold, following the instructions; loose sockets transfer heat poorly.
Keep the non-stick coating of the sockets clean; clean it the way the manufacturer recommends, and never scrape it with a knife or metal object.
After welding, unplug the welder and let it cool completely on its stand before packing it in its case.
uPVC solvent cement and accessories
uPVC solvent cement (and cleaner/primer if the pipe system requires it) is a consumable "tool", but it must be in your bag when working on drain lines. Close the lid immediately after use, work in a ventilated area and keep it away from flames, because the solvent is flammable; keep a few clean dry cloths to wipe pipe ends before applying cement.
Thread-sealing materials
PTFE tape (thread seal tape): wrap clockwise when looking at the end of the thread, in the tightening direction, so the tape does not come off as you screw it in. The number of turns depends on the thread size and how tight the thread fits; detailed instructions are in the lesson wrapping PTFE tape on threaded joints.
Thread sealant/sealing cord (if used): only use types suitable for drinking water and follow the instructions on the packaging.
Spare rubber washers in common sizes: supply hose washers, tap washers, trap washers. Many leaks at the end of a supply hose only need a new washer.
Do not wrap PTFE tape on joints with flat washers (for example a flexible supply hose screwed onto an angle valve with a built-in washer): these joints seal because the washer is pressed flat, and extra tape can make the washer seat unevenly.
Group 4: Tightening and loosening threads and nuts
This is the group new plumbers misuse most often. The principle: choose a tool that fits snugly and suits the type of surface, and always hold the other side.
Commonly used tools
Standard adjustable spanner (flat jaws): for hex nuts, supply hose ends, tap bodies and angle valves. Turn the worm screw until the jaws grip the nut tightly with no gap; loose jaws will round off the corners of the nut. It is worth having two sizes (one small, one medium).
Pipe wrench (Stillson): with toothed jaws, used to grip round pipes such as galvanized steel pipe and metal threaded ends. The teeth leave bite marks, so do not use it on chrome-plated nuts, polished taps and valves, or plastic fittings.
Water pump pliers (slip-joint pliers): jaws with several adjustment positions, quick to use on trap nuts, pipe ends and flexible hoses. When gripping a plated surface, put a piece of cloth or thin rubber in between to avoid scratching it.
Spanner set, hex keys, screwdrivers: for removing tap cover caps, lever handle screws, toilet fixing screws and bracket bolts.
Box spanner/basin wrench (if available): to reach nuts in tight spaces behind washbasins and sinks.

Figure 3. A 350 mm pipe wrench: toothed jaws, with the opening adjusted by a red knurled ring. This tool is for gripping round metal pipes; the teeth can scratch plated surfaces. (Photo: Kindel Media, Pexels; rotated horizontally, cropped, brand name blurred)
The "one holds, one turns" principle
When tightening or loosening a threaded joint connected to a valve, meter or fitting that is already fixed in the wall, you must use two tools: one holds the fitting body still, and the other turns the nut or pipe. If you only turn one side, the twisting force is transmitted into the pipe behind, which can rotate or crack the pipe or open up a joint inside the wall – a place you cannot see until the wall starts to get damp.
Tighten just enough
Threaded plastic fittings usually only need to be hand-tight plus a little more with a tool; over-tightening easily cracks them. Supply hose ends with washers: tighten until the washer is compressed and sealed; if it still leaks, check the washer before tightening further. With PTFE-taped metal threads, avoid backing off to adjust the direction, as this can break the tape seal.
Group 5: Drain-clearing tools
Rubber plunger: the first tool for toilets, washbasins and sinks. For toilets, use a flanged plunger that seals around the outlet. When plunging a washbasin, block the overflow to build up pressure.
Drain snake (hand-cranked drain auger): fed into the pipe to hook out or break up the blockage when the plunger does not work. The end of the cable is usually coiled to catch debris and hair.
Electric drain-cleaning machine (optional): for long pipe runs and hard blockages; only use one after training, wear the special gloves recommended by the manufacturer, and never wrap the cable around your hand.
Plastic hair-removal hook, long reach grabber, inspection mirror and torch: for floor drains and bathroom traps.

Figure 4. Close-up of the end of a drain snake cable: the coiled steel tip is used to hook debris, and behind it is the coiled spring cable. (Photo: Frank C. Müller, Wikimedia Commons, CC BY-SA 4.0)
How to use a drain snake safely:
Wear gloves and glasses; lay a tarp or towel under the work area.
Feed the cable in slowly, pushing and turning in one direction; when you meet an obstruction, turn so the tip hooks or passes through it, and do not ram it into bends (elbows), as this can damage the pipe or the toilet’s glaze.
Pull the cable out slowly, wiping each section clean with a rag, and do not let it whip and splash dirty water.
Flush water several times to make sure the pipe is clear.
Wash, dry and coil the cable neatly; a rusty cable will snap the next time you use it.
If the client has already poured drain-cleaning chemicals into the pipe, ask exactly which product before you start: the water in the pipe may be caustic and can splash into your eyes. In that case you must wear glasses and gloves, work slowly, and not add any other chemical. A step-by-step procedure for unblocking toilets is in the lesson blocked toilet with water rising when flushed.
Group 6: Testing, electrical safety and protection
Pressure test pump and pressure gauge
After installing a new water supply line (especially before plastering walls or pouring floors), the pipework must be pressure tested: pump water into the system, raise the pressure to the test level required by the design or the pipe manufacturer’s instructions, and watch the gauge for a period of time. The usual tool is a hand pressure test pump with a water reservoir, pump lever, release valve and pressure gauge. The test pressure and holding time are not one figure for every project; the step-by-step method is in the lesson installing hot and cold supply lines and pressure testing before plastering.

Figure 5. A hand pressure test pump on the floor: blue water reservoir, long pump lever on top, pressure gauge and red hand valve, with a flexible hose attached. According to the photographer, this pump is used for testing boilers and pressure vessels; pumps for testing water pipework have a similar design. (Photo: K. Krallis, SV1XV, Wikimedia Commons, CC BY-SA 3.0)
Notes when using a pressure test pump:
The gauge must work and return to 0 when there is no pressure; its range must suit the test pressure.
Pump slowly and bleed all the air from the pipes first (open the tap at the highest point until water flows, then close it); air in the pipes makes the needle fluctuate and gives false readings.
Do not pump above the test pressure; do not stand in front of end caps or plugs while raising the pressure.
After testing, open the release valve to remove all pressure before disconnecting the pump.
The pressure gauge also helps with diagnosis: measuring water pressure after a pump, and checking for pressure drop when tracing leaks (see the lesson finding concealed in-wall leaks without breaking out).
Electrical testing tools
Plumbers often work next to pumps, water heaters, washing machines and water purifiers – all electrical and all located in damp places. Two minimum items:
A voltage tester pen for quick checks on appliance casings and power cords.
A multimeter (if you have been trained to use one) to confirm there is no voltage before disconnecting wires, and to check fuses and pressure switches.
The rule: switch off the circuit breaker (MCB) feeding the appliance and verify with a tester before disconnecting any water line or touching any wire ends. Connecting or repairing the electrical parts inside appliances should be left to someone with electrical qualifications. Do not remove a water heater’s safety components (such as the safety valve or anti-shock device) yourself unless the manufacturer’s instructions allow it.
Drilling, chiselling and working at height
Drill (with hammer mode) and masonry/tile bits: for mounting brackets for water heaters, pipes and basins. Before drilling, locate concealed water pipes and electrical cables using drawings, photos taken before plastering, or a detector. Note that metal detectors may not detect plastic pipes, so do not rely entirely on the device.
Chisel, hammer, wall chaser (for installation work): to cut chases for concealed pipes. Wall chasers create a lot of dust: wear glasses and a dust mask, and use water or a vacuum if available.
A-frame stepladder: tall enough, with firm feet and the spreader braces fully locked. When you have to go onto a roof, terrace or elevated water tank: have someone hold the ladder, and do not work in rain or strong wind.
Personal protective equipment
Safety glasses: when drilling, chiselling, sawing, clearing blockages and working with chemicals.
Gloves: fabric/leather gloves for mechanical work; rubber or nitrile gloves for clearing blockages and septic tank work.
Non-slip shoes (wet bathroom floors are very slippery), a mask, and earplugs when using a hammer drill for long periods.
Head torch: under basins and in service ducts it is usually dark; it keeps both hands free.
Group 7: Job-site cleaning supplies – what clients remember longest
Clients may not be able to tell a good weld from a bad one, but they remember very clearly a plumber who left the floor wet and dirty. A compact cleaning kit includes:
Tarp or floor protection sheet: laid under the work area and along the path where you carry tools.
Bucket and small tray to catch water: placed under traps, valves and pipe ends before disconnecting (as in the cover photo), because there is always water left in the pipe even with the valve closed.
Rags, absorbent cloths, sponges: to wipe up water and to wipe your hands before touching the client’s fixtures.
Shoe covers or separate slippers when entering homes with wooden floors or carpets.
Rubbish bags: for pipe offcuts, old PTFE tape and packaging; take them away, do not leave them behind.
Wet/dry vacuum (if available): to suck up spilled water and drilling dust.
A good habit: photograph the work area before and after the job, and run water to show the client the result.
Reference table: tools, uses and notes
Tool | Used for | Key notes |
|---|---|---|
Tape measure, marker | Measuring, marking cut positions and insertion depth | Add the length that goes into the fitting when measuring |
Spirit level | Checking level and drain pipe slope direction | Exact slope according to the design |
Plastic pipe cutter | Cutting small PPR, PE and uPVC pipe | Do not exceed the maximum pipe size marked on the cutter |
Hacksaw | Cutting large uPVC pipe, steel pipe, threaded rod | Teeth pointing forward; deburr after cutting |
Wheel pipe cutter | Cutting copper, thin stainless steel, small galvanized pipe | Tighten a little at a time, not all at once |
PPR welder + welding sockets | Welding PPR pipe and fittings | Keep on the stand; plug in through an RCD; follow the manufacturer’s time table |
uPVC solvent cement | Gluing uPVC drain and supply pipes | Ventilation, away from flames, keep the lid closed |
PTFE tape, washers | Sealing threaded and washer joints | Do not tape flat-washer joints |
Standard adjustable spanner | Hex nuts, supply hose ends, valves | Snug jaws; use a second tool to hold |
Pipe wrench | Gripping round metal pipes | Not for plated surfaces or plastic parts |
Water pump pliers | Trap nuts, pipe ends | Pad with cloth on polished surfaces |
Rubber plunger | Unblocking toilets and washbasins | Block the overflow when plunging a washbasin |
Drain snake | Clearing blockages inside pipes | Turn in one direction; gloves and glasses; dry after use |
Pressure test pump + gauge | Leak-testing new supply lines | Test pressure and duration according to the design/manufacturer |
Voltage tester pen, multimeter | Confirming there is no voltage | Switch off the breaker first, verify, then work |
Drill, drill bits | Mounting brackets, drilling walls | Locate concealed pipes and cables before drilling |
Tarp, bucket, rags, rubbish bags | Keeping the client’s home clean | Place the bucket before disconnecting any joint |
In what order should you buy tools?
You do not need to buy everything on day one. A suggestion (for reference) by stage of training:
Stage 1 – Small repairs in the home
Tape measure, marker, two sizes of adjustable spanner, water pump pliers, a screwdriver and hex key set, PTFE tape, spare washers, plastic pipe cutter, plunger, short drain snake, voltage tester pen, head torch, glasses, gloves, tarp, bucket, rags. This kit is enough for most jobs replacing taps and supply hoses, fixing leaking connections and clearing simple blockages.
Stage 2 – Installing fixtures and short pipe runs
Add a spirit level, hacksaw, deburring tool, pipe wrench, a PPR welder with sockets in the sizes you use most, uPVC solvent cement, a drill and drill bits, and an A-frame stepladder.
Stage 3 – Plumbing a whole house
Add a pressure test pump with gauge, wall chaser, laser level, electric drain-cleaning machine, wet/dry vacuum and multimeter. By this point you will have the experience to know which type and size you need.
Buy later-stage tools once you have been trained to use them; a good machine in the hands of someone who does not know how to use it can still ruin the job or cause an accident.
Organizing and caring for your tools so they last and nothing gets left behind
Divide your bag by task group: one compartment for "tightening and loosening", one for "cutting and joining", one for "clearing blockages", and a small box of consumables (washers, PTFE tape, nuts). Open the bag and you can see at once what is missing.
Keep drain-clearing tools separate in a bag or lidded box, wash them after every use, and do not store them with tools for clean water installation.
Dry metal tools after working in wet areas; occasionally put a drop of oil on spanner worm screws and plier joints so they do not rust or seize.
Power tools: check the power cord and plug before every use; replace a cracked cord or loose plug immediately, do not patch it with tape and carry on using it.
Count your tools before leaving the client’s home, and check the work area again, including inside service ducts.
Common mistakes when using tools
Using a pipe wrench on a chrome-plated nut → the nut gets bitten and scratched.
Turning with one tool without holding the other side → the pipe rotates and a joint in the wall opens up.
Adjustable spanner opened wider than the nut → the corners of the nut get rounded off.
Cutting pipe that is too large for the cutter, or using a blunt cutter → the pipe end is deformed and the joint does not seal.
Putting a hot PPR welder down on the floor → burnt floor, burns, damaged welding sockets.
Not placing a bucket before removing a trap or valve → dirty water spills onto the floor.
Disconnecting the water line of a water heater or pump without switching off the power → risk of electric shock.
Drilling a wall without locating the pipe route → drilling through a pipe.
Safety checklist before starting a job
☐ Asked the client where the main valve and the circuit breakers for the relevant appliances are.
☐ Closed the supply valve for the work area and released the pressure (opened the lowest tap) before cutting or disconnecting.
☐ Switched off the power and verified with a voltage tester/multimeter for pumps, water heaters and washing machines.
☐ The socket for the welder and drill has shock protection; cables are not lying in water.
☐ Located concealed pipes and cables before drilling or chiselling.
☐ Wearing glasses when cutting, drilling, chiselling and clearing blockages; gloves suited to each task.
☐ Welder on its stand, away from flammable materials; solvent cement lid closed, in a ventilated place.
☐ Ladder stable, with someone holding it when working at height.
☐ Tarp, bucket and rags ready.
☐ When finished: reopen the valve slowly, check for leaks, clean up, count your tools.
Frequently asked questions
Should a new plumber buy a complete tool set or individual tools?
A complete set is convenient but usually includes many rarely used items while missing things a plumber needs, such as a plastic pipe cutter, plunger and drain snake. Buying individual tools from the Stage 1 list above gives you exactly what you use every day, and you can then add to it gradually based on real jobs.
What is the difference between an adjustable spanner and a pipe wrench, and does it matter if I mix them up?
An adjustable spanner has two flat jaws that grip a hex nut. A pipe wrench has serrated jaws that grip round pipe tightly. Using a pipe wrench on nuts or plated taps leaves tooth marks; using an adjustable spanner on round pipe tends to slip. Each has its own job.
Do I need to buy a PPR welder right from the start?
If you mainly do small repairs, not yet. You only need a welder and sockets in the common sizes when you start taking on PPR pipe installation jobs. Before welding for clients, practise on offcuts and cut the welds in half to inspect them.
Is a voltage tester pen enough to be sure the power is off?
A tester pen is useful for quick checks but can give false readings when its battery is weak or contact is poor. The safe method is to switch off the breaker feeding the appliance, test the pen on a known live source to make sure it works, and only then test the appliance. If you are not sure, ask someone with electrical qualifications to check.
Can drain-clearing tools also be used for clean water installation?
Better not. Drain snakes, plungers and drain-clearing gloves come into contact with waste water; keep them separate, wash them, and do not mix them with tools and materials used for clean water lines such as welding sockets, washers and PTFE tape.
Practice exercises
Tool inventory: list all the tools you currently have and sort them into the seven groups in this lesson. Mark the groups that are missing and make a shopping list based on Stage 1.
Practise "one holds, one turns": fit an angle valve onto a threaded pipe fixed to a practice bench. Use two spanners to tighten the supply hose end, and observe whether the pipe behind rotates when you use only one tool.
Practise cutting pipe: cut three pieces of each pipe type (PPR, uPVC) with the appropriate tool, deburr them and check squareness with a try square. Note which pieces were deformed and why.
Practise with a drain snake: stuff a handful of paper into a length of uPVC pipe with an elbow and use the drain snake to hook it out; practise pushing and turning in one direction, then pulling out and wiping clean.
Pack a bag for a scenario: a client reports "the washbasin tap is leaking at the base and the trap is leaking". Write a list of what to bring (tools, materials, cleaning supplies) and the safe sequence you will follow on arrival. Compare it with the checklist in this lesson.
Once you have a basic tool kit, the next step on the roadmap is practising cutting and welding PPR pipe and gluing uPVC pipe. Later, when you take on jobs yourself, do not forget the lesson technical inspection, quoting and taking on jobs so that the tools and materials for each job are planned correctly from the start.