“Our water bill went up this month but we can't see a leak anywhere.” “The bottom of the bedroom wall next to the bathroom is always damp and the paint is bubbling.” “The pump switches itself on for a while every night.” These are a plumber's hardest calls, because the pipes are inside the walls and under the floor. Inexperienced plumbers tend to break open walls on a hunch, opening three spots to hit the right one, and the customer pays extra for retiling. Good plumbers follow a sequence: prove there is a leak, isolate the branch, pressure test, narrow down the area, and only then open up one spot.
This lesson extends the “Repairing common leaks & clearing blockages” step. It reuses the pressure-testing skills from the “Installing water supply lines & pressure testing” step and the PPR welding skills from step 2. By the end of this lesson, you will be able to: (1) confirm that there is a leak using the water meter or the roof tank; (2) isolate the leaking branch using shut-off valves and pressure testing; (3) distinguish a leak in a supply pipe from a leak in a drain pipe, a waterproofing failure or condensation; (4) open up the right spot, repair it, retest and hand over.
Principles of narrowing down a leak
Prove first, break open later
Do not open anything until you have two pieces of evidence: water is being lost when nobody is using it (meter or tank level), and which branch is losing water (pressure test). A damp patch is only a clue, because water can run along the pipe or through the mortar layer and appear at a spot quite far from the actual leak.
Keep splitting in half
Like tracing a broken wire, leak detection works by halving: shut off half the system and see whether the leak continues; then shut off half of that half… Each test eliminates half of the pipework. To do this, you need to know where the branch shut-off valves are — if the house has no branch valves, you may have to isolate temporarily by removing end fittings and capping the pipe ends.
Supply pipes are pressurized, drain pipes are not
Supply pipes are always under pressure, so they leak continuously, even when nobody is using water. Drain pipes only leak when water flows through them (when showering, flushing the toilet, draining the basin). If the bathroom floor waterproofing has failed, damp increases after showering and gradually dries when the bathroom is not in use. Watching when the damp increases helps you tell them apart very quickly.

Figure 1. A group of water meters on a supply pipe, each with its own shut-off valve. Turn off all the taps: if the small needle or wheel on the meter face is still turning, the pipework after the meter is leaking. (Photo: Nizil Shah, CC BY-SA 4.0, Wikimedia Commons)
Tools and preparation
Tools
Flashlight, notebook, marker pen, masking tape for marking measurement points.
Hand pressure-test pump with pressure gauge, plugs and adapters for various pipe sizes.
Material moisture meter; thermal camera if available (useful for hot water pipes); stethoscope or acoustic listening device.
Detector for electrical cables and metal in walls.
PPR welding kit, couplers, repair fittings, uPVC cement and fittings if the drain pipe needs repairing.
Tile cutter, small chisel, dust sheets.
Questions to ask the customer over the phone
Does the house use mains water directly, or does it have a pump and a roof tank? Where is the water meter?
How many cubic meters per month has the bill gone up by (look at the m³ figure on the bill, not the amount of money)?
Where is the damp patch, and does it get worse after showering or is it damp all day?
Does the pump switch itself on when nobody is using water?
Does the house have pipe drawings or photos taken during construction? In an apartment building, has the unit above recently renovated its bathroom?
7-step leak detection procedure
Confirm there is a leak. House on direct mains supply: turn off all taps, the washing machine and the toilet (close the angle stop valve), note the meter reading and watch the small needle or wheel on the meter face. Read it again after 30–60 minutes. House with a roof tank: switch off the pump power, mark the water level in the tank, use no water for 1–2 hours, then check.
Rule out end fittings and appliances. Check the toilet (dye test), taps, the water heater, the roof tank float valve and the water purifier. Leaks at appliances are easier to fix and more common than concealed in-wall leaks. After closing the stop valves for the appliances, read the meter again.
Draw a branch diagram. Walk through the house and note the location of the meter, pump, tank, main shut-off valve, and the shut-off valves for each floor and each room. Number the valves. Ask the customer or look at construction photos to work out the pipe routes.
Isolate branches using the shut-off valves. Close each branch valve in turn (or close half of the branches at a time) and watch the meter or tank level. The branch that makes the meter stop turning when closed is the leaking branch.
Pressure test the suspect branch. Isolate the branch, cap the outlets and connect the test pump. Test as in the water supply installation lesson: test pressure about 1.5 times the working pressure, usually not less than 6 bar, stabilize for about 30 minutes while topping up with the pump, then monitor for about 1–2 hours. A pressure drop of more than about 0.5 bar means the branch fails. Record the rate of pressure drop.
Narrow down the location. On the identified branch, take moisture readings in a grid on the wall and floor, writing the numbers on masking tape. For hot water pipes, run hot water and use a thermal camera to look for unusual warm streaks. While the branch is under test pressure, listen closely against the wall at suspect points. Combine this with the pipe routes worked out from the diagram and the positions of the outlets.
Open one spot, repair, retest. Scan for electrical cables, switch off the circuit breakers for nearby circuits and put down dust sheets. Cut out one tile or a small square at the spot with the most evidence. Repair the pipe, pressure test again until it passes, let it dry and check once more before plastering and tiling.
Safety: bathroom and kitchen walls usually contain electrical cables for sockets, water heaters and lights. Always scan for cables and switch off the breakers for circuits near the area you are drilling or chiselling. When tracing hot water pipes, beware of scalding — switch off the water heater and run the water until it is cool before cutting the pipe. Wear goggles and a mask when cutting tiles. Never pressure test domestic water pipework with compressed air.
Tips for reading the water meter
Many meters have a small needle or star-shaped wheel that turns very sensitively, showing even small leaks before the digits have moved.
Take photos of the meter face before and after, with the time on the photo, as evidence for the customer.
If the meter keeps turning even when the main valve right after the meter is closed, tell the customer to contact the water supply company — the section before the meter is not something the plumber repairs.

Figure 2. A manifold with several pipe branches, each with its own valve. Number each branch and each valve like this on your diagram before testing — it is your map for narrowing down the leak.
Table for distinguishing sources of damp and how to check them
The table below is common practice for residential homes, given as a guideline; hot water lines supplied by 220 V/50 Hz electric water heaters are checked the same way.
Suspected source | Typical signs | How to check |
|---|---|---|
Cold water supply pipe leaking | Continuous damp, meter turning with taps closed | Isolate the branch, pressure test |
Hot water supply pipe leaking | As above, may feel warm when hot water is used | Pressure test, thermal camera while hot water is running |
Drain pipe leaking | Damp increases right after water is drained, dries when not in use | Run colored water into each drain point and observe |
Bathroom floor waterproofing failed | Damp at the base of the wall in the next room after showering | Flood test on the floor after ruling out the pipes |
Rainwater seepage | Damp increases after rain, on external walls | Observe in relation to the weather |
Condensation | Water beading on the surface of cold pipes or cold walls, humid weather | Wipe dry and observe again; unrelated to the meter |
Note: a house can have two sources of damp at the same time. If the wall is still damp after showering once the supply pipe has been repaired, go on to check the drain pipe and the waterproofing.
Worked example: a three-story house with the pump running at night
The situation
A three-story townhouse: mains water goes into an underground tank, a pump lifts it to a roof tank, and each floor is fed from the roof tank. The customer says the pump switches itself on every night, and the base of the second-floor bedroom wall next to the bathroom is damp with bubbling paint.
Narrowing down and calculating
You check the roof tank float valve: it closes properly. You switch off the pump, mark the water level in the tank and close the stop valves for the appliances. After 2 hours, the level has dropped noticeably — there is a leak in the supply line from the tank down. You close the third-floor branch valve: the level still drops. You close the second-floor branch valve: the level stays put. The second-floor branch is the leaking branch.
From the drop in level and the tank dimensions, you estimate the leak at about 12 liters per hour. That is about 12 × 24 = 288 liters per day, or about 288 × 30 ≈ 8,640 liters per month, which is about 8.6 m³. This calculation comes from the measurements in this case and is enough to help the customer understand why the pump keeps running.
Pressure test the second-floor branch at 6 bar: after the stabilization period, 4.8 bar remains after 1 hour — a drop of 1.2 bar, a fail. Moisture readings in a grid on the bathroom wall adjoining the bedroom: the highest area is about 40 cm below the shower valve, between the hot and cold outlets. With hot water running, the thermal camera shows no warm streak there, so you suspect the cold pipe.

Figure 3. A dial pressure gauge mounted on a pipe. When pressure testing each branch, record the reading once it has stabilized and again after one hour: a branch with a clear pressure drop is the leaking branch.
The fix and the retest
You scan for cables: a cable for the water heater socket runs horizontally above, about 30 cm from the suspect area. You switch off that circuit's breaker and the water heater breaker, put down dust sheets and cut out one tile. The cold PPR pipe has a crack right next to a welded elbow, possibly caused by overheating the weld during installation. You cut out the damaged section and weld in a new piece of the correct pipe type with couplers.
Retest the branch: stabilize for 30 minutes while topping up, monitor for 1 hour, drop below 0.5 bar — pass. You let the wall dry for a few days, take moisture readings again and see them falling, and only then plaster and refit the tile. The roof tank level no longer drops when no water is being used, and the pump no longer runs at night.
Repairing the leak by pipe type
PPR pipe
Cut out the damaged section, leaving two pipe ends that are long enough and clean enough to weld. If there is not enough room to get the welding tool in, enlarge the tile opening a little rather than trying to weld at an angle. Weld on a coupler, or join in a new piece of pipe with two couplers, at the temperature and time given in the manufacturer's table, as in step 2. The inside of the pipe must be dry; if water is dripping from the branch above, close that branch and drain it first. Some manufacturers make dedicated repair fittings for hard-to-reach spots — use the correct type and follow the manufacturer's instructions.
uPVC pipe or drain pipe
Cut out the damaged section, clean it, chamfer the edges, and use a coupling or socket with the correct solvent cement for the pipe type. Wait for the cement to cure for the time stated by the manufacturer before running water and testing.
Old galvanized steel pipe
Old, rusty galvanized pipes usually leak at the threaded joints and have thin walls in many sections. Repairing one spot can be followed immediately by a leak somewhere else. Tell the customer clearly about the risk and propose replacing the line with new pipe when possible; do not promise that fixing one spot will stop the leaks.
After the repair
Always pressure test the whole branch again, not just look at the repaired joint. Record the result in the job report and photograph the repair before plastering.
Common situations
The house has no branch shut-off valves
You have to isolate by removing end fittings and capping each pipe end, then pressure testing cluster by cluster. Suggest that the customer has branch valves installed during the repair — next time leak detection will be much faster.
Leak under the bathroom floor
This usually means opening up the floor and redoing the waterproofing, which costs much more than repairing a pipe in a wall. Explain the scope of work in advance and suggest bringing in a waterproofing specialist to work alongside you.
Apartment building, water seeping from the floor above
A damp patch on your customer's ceiling or wall may come from the unit above. Never enter or interfere with another apartment yourself. Advise the customer to take it up with the building management.
The meter turns even with the main valve closed
The leak is before the house's main shut-off valve, or the main valve does not seal. If the leaking section is before the meter, advise the customer to report it to the water supply company.

Figure 4. A moisture meter pressed against a brick wall, showing the reading on its display. Take readings in a grid of many points on the wall to narrow down the suspect area. (Photo: Etan J. Tal, CC BY-SA 4.0, Wikimedia Commons)
Common mistakes
Breaking open the dampest spot straight away — sign — you open it and find no pipe. Cause — water ran through the mortar layer, the leak is elsewhere. Fix — pressure test the branch and use the pipe diagram before opening anything.
Not ruling out end fittings and appliances — sign — you break open the wall but the real leak is in the toilet cistern. Cause — skipping step 2. Fix — dye test the toilet and check the float valve first.
Chiselling into an electrical cable — sign — the breaker trips, risk of electric shock. Cause — not scanning for cables and not switching off. Fix — always scan for cables and switch off the breakers for nearby circuits.
Not stabilizing the pressure test first — sign — pressure drops in new pipe and you wrongly conclude it is leaking. Cause — not waiting for the stabilization phase. Fix — stabilize for about 30 minutes while topping up before you start counting.
Plastering straight after the repair — sign — it leaks again and you have to break it open a second time. Cause — no retest. Fix — only plaster once the pressure test passes.
Mistaking condensation for a leak — sign — the wall is wet on humid days but the meter does not turn. Cause — not cross-checking with the meter. Fix — always check the meter or tank level first.
When to stop and call the responsible party: a leak in the section before the water meter (report to the water supply company); a leak from another apartment or from shared pipework in an apartment building (report to building management); an area to be opened that is close to beams or columns, or that shows signs of structural cracking; leaking water that has got into the electrical board or sockets — switch off the power to that area and have an electrician inspect it before switching back on.
Reporting to the customer
Record: the meter readings or tank levels before and after, the leaking branch, the test pressure and pressure drop before and after the repair, photos of the leak point before plastering, and an estimate of the water lost with clearly stated assumptions.
Sample report wording:
“When I closed the branches one by one, only the second-floor branch made the roof tank lose water. The pressure test on that branch dropped 1.2 bar in 1 hour. After taking moisture readings and scanning for cables, I opened exactly one tile below the shower and found the cold pipe cracked next to a welded elbow. I've replaced that section of pipe and the retest passed. Please let the wall dry for a few days, and I'll come back to plaster and refit the tile. If you notice the pump running on its own at night again, let me know.”
Prices for leak detection, repairs and retiling vary by region and over time; quote the customer for the survey first, and quote for the opening-up and repair after you have narrowed down the leak.

Figure 5. A plumber tightening a pipe fitting with a wrench. With concealed PPR pipe, the damaged section is replaced with heat-welded couplers; whichever repair method is used, pressure test again before plastering and tiling.
Frequently asked questions
How do I know if a house has a concealed in-wall leak?
Turn off all taps and water-using appliances, read the water meter, then read it again after 30–60 minutes. If the reading has gone up or the small needle is still turning, the pipework after the meter is leaking. Only then start isolating branch by branch.
How do I check a house with a roof tank?
The meter only measures water going into the tank. Switch off the pump, mark the water level in the tank, close the valve after the tank or close each branch in turn, and watch. If the level drops when nobody is using water, there is a leak in the supply pipework from the tank down.
Is a damp patch on the wall definitely caused by a leaking water pipe?
No. Damp can come from a drain pipe, failed bathroom floor waterproofing, rainwater seepage or condensation. Pressure testing the supply pipes is how you distinguish a supply pipe leak from the other sources.
Do I need a specialist leak detector?
Not necessarily. The water meter, branch shut-off valves and a pressure-test pump can narrow down most cases. A moisture meter, thermal camera or acoustic listening device helps pinpoint where to open up, especially with long pipe runs.
Do I need to switch off the power before drilling and chiselling a wall to repair a pipe?
Yes. Walls usually have electrical cables running close to the water pipes. Scan for cables before drilling or chiselling, and switch off the breakers for circuits near the work area, especially sockets and water heaters in the bathroom.
Practice exercises
Draw a diagram of the water supply branches and shut-off valve locations in the house you live in.
On a pipework model with a hidden leak (prepared by the instructor), use the branch shut-off valves and a pressure-test pump to identify the leaking branch.
Take moisture readings in a grid on a sample wall, record the numbers and identify the suspect area.
Cut and re-weld a section of PPR pipe with a coupler, and pressure test it to the required standard.
Calculate the monthly water loss from a 1-hour meter reading.
Self-assessment criteria — you pass when:
You prove there is a leak using the meter or tank level before doing anything else.
You correctly identify the leaking branch using shut-off valves and pressure testing.
You scan for cables and switch off the power before drilling or chiselling.
You open only one spot and find the leak.
The post-repair pressure test passes before you plaster.
After this lesson, move on to the “Technical inspection, quoting & taking on jobs” step, where you learn how to quote for leak detection jobs when the scope is still unclear.