"The water came back this morning, but when I open the tap it keeps spluttering, the water spurts out in bursts and splashes everywhere, flowing and stopping." Plumbers often get calls like this after mains water cuts, a roof tank running dry overnight, a pump sucking in air, or just after repairing or installing new pipework. The culprit is usually air trapped in the water supply pipes.
In most cases, bleeding the air in the right order is all it takes. But if the tap splutters again every day, air is getting in from somewhere: a leaky pump suction pipe, a faulty foot valve, a roof tank running dry, or a pipe route that forms an air pocket. If you just bleed the air and leave, the customer will call again a few days later.
By the end of this lesson, you will be able to recognise the symptoms correctly, find where air is getting in, bleed the air in a sensible order, know when an air release valve is needed and handle the water heater safely when the water supply is lost. For a "bang" when a tap is shut quickly, see the lesson Water pipes knocking, vibrating and banging when a tap is closed (water hammer); for water that flows steadily but weakly, see Weak shower flow: 7 steps to find the cause.
How does air get into the pipes?
Air can only get in when a pipe has been drained or there is an opening somewhere. Common situations:
Mains water cut: the water in the house pipes gradually drains out through the taps and air rushes in to take its place. When the water comes back, the air is pushed along towards the taps.
Roof tank runs dry: a stuck float valve, a faulty electric float switch, a pump that doesn't fill the tank, or the household using too much water. When the level drops close to the outlet, the water forms a vortex and draws air down into the pipe.
The pump sucks in air: a leaky joint on the suction pipe, a foot valve that doesn't seal, the water level in the underground tank or well dropping close to the suction inlet, or a booster pump drawing from a nearly empty roof tank.
Just repaired or newly installed: after replacing a burst pipe section or completing a system, the pipework is initially full of air.
A pipe route that forms an air pocket: a pipe that loops up over a beam or runs horizontally above the ceiling before coming down. Air is lighter than water, so it collects at the high point and stays there.
Recognising the symptoms: is it really air in the pipes?
When you open the tap you hear spluttering and gurgling, the water spurts in bursts before flowing steadily; showers and bidet sprays jerk.
The water comes out milky white, and if you pour it into a glass and leave it, it clears from the bottom up within a few minutes. That is tiny air bubbles rising.
It is worst the first time a tap is opened after the supply is lost, then gradually gets better.
Telling it apart from water hammer and weak flow
Water hammer is a loud bang when a valve closes quickly (a washing machine valve, a tank float valve shutting suddenly), and it happens even when the pipes are full of water. Air in the pipes shows up mainly when a tap is opened. Refilling the pipes too quickly while there is still air in them can also cause banging. If all the air has been bled and the pipes still bang when a tap is closed, treat it as water hammer.
Weak flow that is steady with no spluttering is usually caused by a strainer, a scaled-up shower head, low roof tank pressure or a valve that isn't fully open. Water that is cloudy yellow or brown with sediment and doesn't clear after a few minutes is caused by scale or rust in the pipes or tank, not by air bubbles.
Quick lookup table: symptoms, causes, checks and fixes
Symptom | Common cause | Check | Fix |
|---|---|---|---|
Whole house splutters after the mains water comes back | Air entered the pipes during the water cut | Ask about the water cut schedule, see whether several taps are affected | Switch off the water heater, refill slowly, bleed air in order |
Splutters every morning or after peak hours, house with a roof tank | Roof tank runs dry, float valve can't keep up or is faulty | Go up to the roof and check the water level, float and pump | Repair or replace the float, adjust the on/off levels, check the pump |
Splutters every time the pump runs, pump needs frequent priming | Leaky suction pipe, foot valve not sealing, low tank level | Suction pipe joints, foot valve, water level in the tank or well | Seal the suction pipe, replace the foot valve, lower the suction inlet, add dry-run protection |
Booster pump after the roof tank switches on and off erratically, taps splutter | Tank nearly empty, pump draws air through a vortex | Water level relative to the tank outlet, is there dry-run protection | Maintain the water level, fit a float switch or dry-run protection relay |
Only one tap or one floor keeps spluttering | Air pocket in a looped section or a pipe above the ceiling | Trace the pipe route, find the branch's highest point | Bleed longer at the tap after the high point, fit an air release valve or re-route |
Hot tap splutters, water heater makes bubbling noises | Heater not yet full or air in the hot branch | Switch off the heater, open a hot tap to see whether the water flows steadily | Fill completely, bleed the hot branch, only then restore power |
Milky white water that clears from the bottom up when left standing | Tiny air bubbles | Pour into a clear glass and leave for a few minutes | Bleed more; if it recurs over several days, find where air is getting in |
A house can have two causes at the same time. Tools to bring: spanners, an adjustable wrench, PTFE tape, a bucket, towels, a torch, a voltage tester and a sturdy ladder; for jobs where you suspect the pump, also bring a foot valve, seals and a float of the right size.
The 6-step procedure for bleeding air and finding where it gets in
Step 1. Safety first: the water heater and the pump
The first question to ask when a customer's house has lost water or the taps are spluttering: "Is the water heater switched on or off?". A storage water heater must always be full of water when it is powered. Many heaters still hold water thanks to the non-return valve in the safety valve assembly, but you can't be sure that valve is still working. If the heater has lost water and is still powered, the heating element can overheat dry and burn out.
Switch off the water heater's dedicated circuit breaker (MCB) as soon as you know the house has lost water, or before bleeding the pipes.
Switch off the power to the pump if the tank or cistern is empty, so the pump doesn't run dry.
Don't touch the cables, sockets or electrical box of the heater or pump with wet hands or while standing in water.
Instantaneous water heaters usually switch on according to the flow; air makes the flow intermittent, so the water runs hot and cold. Switch these off too, and only switch them back on after bleeding the air.
Step 2. Check the water source
Mains water: open the tap nearest the water meter to see whether the water has fully returned. Don't remove or adjust the water meter or the valve before the meter on your own, because they are managed by the water supply company.
Roof tank: open the lid and check the water level, whether the mechanical float valve opens and closes, whether the electric float switch controls the pump correctly, and whether the outlet is covered with sediment. If the tank is empty, it must be filled before opening any taps.
Underground tank or well: is the water level still above the suction inlet? If you see a vortex around the suction inlet while the pump is running, the pump is sucking in air.
For float faults and tanks that don't fill, see the lesson Roof tank overflowing or not filling.

Figure 1. Black plastic water tanks on the roofs of rows of town houses in New Delhi (India). This roof-tank water supply arrangement is very similar to Vietnamese town houses: when the tank runs dry, the pipes below are left empty, and when the water returns the taps easily splutter. (Photo: BohunkaNika, Wikimedia Commons, CC BY-SA 4.0)
Step 3. Refill the pipes very slowly
Don't open the main valve fully straight away. Water rushing into pipes full of air compresses the air pockets, making air and water burst violently out of the taps, sometimes causing banging and loosening weak joints.
Close the cold supply valve to the water heater and the branch isolating valves (if any).
Open one tap at a low point, close to the source (the kitchen tap or a ground-floor yard tap) about half a turn.
Open the main valve (after the water meter or after the roof tank) slowly, listen for the water flowing into the pipes, then gradually open it fully.
Let the first tap run until there is no more spluttering or cloudiness.
Step 4. Bleed the air from each tap in order
The principle: air is lighter than water and collects at high points and at the ends of runs. So start by opening the low taps close to the source so water fills the lower sections, then move to higher and more distant taps. Let the highest, most distant tap run the longest.
Open the more distant cold taps on the lowest floor in turn: washbasin, shower, bidet spray, washing machine tap. Open them moderately.
Go to the floor above and do the same, from the tap nearest the vertical pipe to the most distant tap.
The highest, most distant tap: let it run until the water flows steadily, with no more spluttering or cloudiness.
Close them in reverse order: starting from the low taps near the source and working upwards, closing the highest tap last so any remaining air has a way out. Close them slowly to avoid water hammer.
This is practical experience for town houses, not a mandatory standard. In a system fed down from a roof tank, air still rises to the highest horizontal pipe sections, so pay attention to taps located just after a section of pipe running above the ceiling.
Trade tip: for the first bleed after repairing or installing pipes, remove the tap aerators and the shower head so debris doesn't get caught in them. Point the hand shower at the floor or into a bucket, away from sockets. If you have bled the whole house 2 to 3 times and one tap still splutters for a long time, there is most likely a permanent air pocket upstream of that tap (see Step 6).
Step 5. Fill and bleed the hot branch before switching the heater on
Slowly open the cold supply valve to the heater.
Open the hot tap nearest the heater (turn the shower mixer lever fully to hot). At first air splutters out and the water flow is broken, then it flows steadily.
Only when the hot tap flows steadily and continuously, with no more spluttering, can the heater be considered full.
Open the remaining hot taps in turn to bleed the air from the hot branch.
Check that the joints around the heater and the safety valve are not leaking, and only then switch the circuit breaker back on.
When you need to drain the heater for repairs, do the reverse: switch off the power first, close the cold supply valve, open a hot tap to let air in, and only then drain the water according to the manufacturer's instructions; be careful, the water may still be hot. See also Water heater leaking, safety valve dripping continuously or not heating.
With a solar water heater, don't fill hot evacuated tubes with cold water in strong sunshine, because the tubes can crack from thermal shock; see the lesson Installing an evacuated-tube solar water heater.
Step 6. The air keeps coming back: find and stop where it gets in
a) The roof tank runs dry. Ask the customer at what time it usually happens. If it happens early in the morning or after the whole family has showered and done the laundry, the tank may be emptying faster than it is being filled. Check for a stuck mechanical float valve, an electric float switch cutting the pump too early, or a tank outlet covered with sediment; replace the float, adjust the on/off levels, or advise adding another tank.
b) The pump sucks in air. Always switch off the power to the pump before dismantling or touching the pump or the suction pipe.
Suction pipe and joints on the suction side: the suction side is at a lower pressure than the outside, so a leak draws air in rather than dripping water out while the pump is running, which makes it very hard to spot. When the pump is off, the leaky joint is usually damp or drips water. A commonly used trick: while the pump is running, pour a little water over a suction pipe joint; if the pump suddenly runs more quietly and the water flows more steadily, that joint is leaking. Only do this on joints far from the motor, the capacitor box and the cables; for joints close to the motor, switch the pump off and check another way.
Foot valve (strainer foot valve): if the non-return valve in the foot valve doesn't seal, the water in the suction pipe drains back into the tank when the pump is idle, so next time the pump has to suck air as well, and sometimes loses its prime. Signs: the pump needs frequent priming, or runs for a while before water comes up. Pull up the suction pipe to clean or replace the foot valve.
Low water level in the underground tank or well: lower the suction inlet (still keeping it clear of the bottom so it doesn't suck up mud) or fit an electric float switch for dry-run protection.
Booster pump drawing from the roof tank: when the tank is nearly empty, the pump sucks air and may switch on and off erratically. It needs dry-run protection suited to the pump type. See the lesson Booster pump running continuously or switching on and off repeatedly.
The electrical connections for the pump, the electric float switch and relays should be made by someone with electrical expertise, with a dedicated circuit breaker and earthing according to the manufacturer's instructions.
c) Air pockets caused by the pipe route. If only one branch is affected, look for a section of pipe that is higher than both its ends: looping over a beam, running above a plasterboard ceiling, or running horizontally on the roof. Deal with it from simple to complex: bleed harder and longer at the tap right after that section; fit an air release valve at the highest point; during renovation, re-route the pipe to run straight, without high points that have no way to vent.
Air release valves: when they are needed and how to install them
An automatic air release valve usually has a float inside. When the valve body is full of water, the float rises and closes the vent hole. When air collects, the water level in the valve body drops, the float sinks and opens the hole to let the air out; when the water rises again, the float closes it.

Figure 2. A brass float-type automatic air release valve mounted upright on top of a manifold, with black and red plastic knobs on top. The photo was taken on a heating water system in France; valves for domestic water supply lines work on the same principle. (Photo: The RedBurn, Wikimedia Commons, CC BY-SA 4.0)

Figure 3. A dismantled automatic air release valve: brass body, black cylindrical plastic float, cap assembly with a lever and a needle that closes the vent hole, cap knob, threaded ring and O-ring. Scale on the float or the needle is a common reason why a valve fails to vent or drips water continuously. (Photo: Torsten Bätge, Wikimedia Commons, CC BY-SA 3.0)
When to install one
At the highest point of a looped pipe section that can't be re-routed.
At the top of a vertical pipe or a long horizontal pipe run on the roof in a system with a pump pushing water directly, where air tends to accumulate.
When the equipment manufacturer requires it, for example some solar water heating or heat pump systems.
Town houses supplied from a roof tank with correctly installed pipework usually don't need one; every valve is one more point that needs maintenance.
Installation notes
Install it vertically, in the direction marked on the valve; if it is installed at an angle, the float won't work properly.
Fit a small isolating valve underneath so it can be cleaned or replaced without cutting the water to the whole house.
Put it somewhere easy to access; if it has to go inside the ceiling, provide an access hatch and a drip tray.
Choose a valve whose working pressure and temperature suit the pipework (read the ratings on the valve) and whose materials are approved for drinking water.
Don't put it where it could be submerged in dirty water: when the pipes lose pressure, some valve types let air flow back into the pipe, and if the valve head is submerged in dirty water there is a risk of back-siphonage.

Figure 4. An air release valve installed on top of a large purple pipe section where a recycled water pipeline is raised to cross a bridge. This is a civil works pipe, not a pipe inside a house, but it clearly shows the principle: the air release valve goes at the high point, where the air collects. (Photo: Stebanoid, Wikimedia Commons, CC0 1.0)
Real examples from the job
Case 1. A 4-storey town house after a water cut
The neighbourhood's mains water was cut for a whole day, the roof tank ran dry in the evening, and the water heater on the 3rd floor was still switched on. The next morning the water came back, and every tap in the house spluttered when opened. The plumber switched off the heater's circuit breaker and checked that the tank was full and the float was working normally. He opened the valve after the tank slowly, bled the 1st-floor taps and worked upwards, with the 4th-floor tap bled the longest. When filling the heater, the hot tap spluttered for quite a long time, showing that the heater had lost water, so the plumber recommended checking the heating element before using it again. He told the customer: next time the water goes off, switch off the heater's circuit breaker immediately.
Case 2. A borehole well, taps spluttering every time the pump runs
The customer had to prime the pump several times a week. The plumber switched off the power and found that a suction pipe joint some distance from the pump was damp while the pump was idle. He switched the pump on and poured a little water over that joint, and the pump immediately ran more quietly: the joint was drawing in air. He cut the power, remade the joint, and when he checked the foot valve he found the non-return valve was stuck open with sediment, so he replaced it as well. He primed the pump and ran a test: the water flowed steadily.
Case 3. A new house where only the 3rd-floor bathroom keeps spluttering
The 3rd-floor branch loops over a beam and runs above the plasterboard ceiling before coming down to the taps, so air accumulates in the section above the ceiling. As the route couldn't be changed yet, the plumber installed an air release valve with an isolating valve at the top of that pipe section, with an access hatch and a drip tray.
Safety checklist
Switch off the water heater's circuit breaker when the water supply is lost or before bleeding the pipes; only restore power when the hot tap flows steadily with no more spluttering.
Switch off the power to the pump and confirm it with a voltage tester before touching the pump, suction pipe or electric float switch; don't let the pump run dry.
Don't work near electrical equipment with wet hands or while standing in water.
Hot water in the heater and pipes can cause scalds; bleed the hot branch carefully and wear gloves when undoing hot joints.
When working on the roof or on top of a tank: a sturdy ladder, non-slip shoes, someone to help, a handhold or a safety harness; don't go up on the roof in rain or strong wind.
Don't interfere with the water meter or the water supply company's pipework on your own.
Frequently asked questions
Can air in the pipes make the water meter turn?
Air passing through a mechanical water meter can make the counter move, but how much depends on the meter type and the amount of air, and it is hard to determine precisely. If the customer suspects an unusually high bill after a water cut, record the meter reading and the time of the cut and contact the water supply company. Plumbers should not fit extra devices before the meter on their own.
Is milky white water safe to use after the supply comes back?
If it clears from the bottom up after a few minutes, it is just tiny air bubbles. Water that is cloudy yellow or brown, with sediment or an unusual smell, needs more flushing and a check of the tank (see the lesson Cleaning and flushing roof tanks and underground tanks), and should be reported to the water supply company if it persists.
Why do the taps splutter a little every morning?
Usually because the roof tank runs dry early in the morning, a leaky foot valve lets the water in the suction pipe drain back into the tank, or there is an air pocket in a high section of pipe. Check the tank level at the time it usually happens and watch whether the pump needs re-priming.
The pump runs but no water comes up and it is noisy — is that caused by air?
Usually the pump has lost its prime because it sucked in air: a leaky suction pipe, a faulty foot valve or an empty tank. Switch off the pump immediately to avoid running it dry, deal with the source of the air, then prime the pump according to the manufacturer's instructions.
Practice exercises
Draw a diagram: draw the water supply diagram of a 3- to 4-storey town house with a roof tank, a pump and a water heater; mark the highest point of each branch and write down the order for opening and closing the taps when bleeding air.
Observe cloudy water: pour a glass of milky white water right after bleeding a tap, leave it to stand, and record how long it takes to clear and whether it clears from the bottom up or the top down.
Air bleeding practice: under the supervision of an instructor, close the valve and drain a branch, refill it slowly, bleed the air in the right order, including switching the water heater off and on again.
Role play: the customer says "Just bleed the air for me, why bother checking the pump?" Explain in 1 minute why you need to find where the air is getting in when the taps keep spluttering.