“Every night we hear the cistern refilling for a while by itself.” “There’s always a trickle of water running down the inside of the toilet bowl.” “Our water bill went up this month and we don’t know where it’s leaking.” A toilet that keeps running is one of the most common plumbing repairs, in the same family as a dripping tap. Most jobs take just thirty minutes and one small washer — if you diagnose correctly. When a plumber replaces the whole cistern fitting set without testing, the client usually does not call them a second time.
This lesson is an extension of the “Fixing common leaks & blockages” step and follows on from the “Installing a toilet” lesson in the sanitary fixtures step. By the end of this lesson, you will be able to: (1) understand how a cistern is built and its two main leak paths; (2) diagnose with a dye test and by watching the water level for the first fifteen minutes; (3) deal with the six most common causes, from adjusting the float to replacing a valve; (4) re-test and report to the client with an estimate of the water saved.
Understand the cistern before you repair it
Two valve assemblies, two leak paths
A cistern has two main assemblies. The fill valve (float valve) lets water into the cistern and shuts off when the float rises to the set level. The flush valve holds water in the cistern and opens when you press the button or pull the lever. Water can only run continuously into the bowl by two paths: through a leaking flush valve, or by spilling over the top of the overflow pipe when the water level is too high. Every diagnostic step is aimed at answering one question: which path?
Valve types commonly found in Vietnam
Sliding-float fill valves (the float wraps around the valve body and is adjusted with a clip or screw) and ball-and-arm fill valves (a round float at the end of an arm, the older style).
Flapper flush valves with a chain (older, budget toilets) and tower flush valves with a dual-flush push button (common on TOTO, INAX, Viglacera, Caesar and many other brands).
Concealed in-wall cisterns: the valves sit inside a frame in the wall and are reached through the flush plate.
Each brand has its own parts, which are often not interchangeable. Always photograph the code printed on the valve body and the toilet model before buying.
The correct water level
As in the toilet installation lesson, the water level after the float shuts off should stop about 2–3 cm below the top of the overflow pipe, or at the water-level line printed inside the cistern by the manufacturer if there is one. Higher than that and water easily spills over into the overflow pipe; too low and the flush will not clear the bowl.

Figure 1. Diagram of a ball-float cistern: the float ball and float rod close the inlet valve when the cistern is full; the handle lifts the piston in the siphon to flush. Modern cisterns use sliding floats and flush valves with seals, but the fill – shut-off – flush principle is the same. (Image: Mcgill, CC BY-SA 2.5, Wikimedia Commons)
Tools and preparation
Tools and materials
Gloves, towels, a small bucket and a sponge to soak up the water remaining in the cistern.
Food colouring or a purpose-made leak-detection dye.
Screwdrivers, spanners, water-pump pliers, a torch, a small brush and vinegar or a mild descaler to clean the seals.
Replacement parts with the correct code: flush valve seal, fill valve washer, a complete valve if needed, and a flexible supply hose.
A ruler to measure the water level.
Questions to ask the client by phone
What brand and model is the toilet? Could you send a photo of the flush button and the cistern lid beforehand?
Does the cistern refill for a while and then stop (common when the flush valve leaks), or does it run continuously without stopping?
Does the button stick, so you have to press it again or jiggle it to make it stop?
Does the house use a booster pump or direct mains water? Has any pipework been repaired recently?
Does the toilet have an electronic seat (which needs to be plugged in)?
The 7-step diagnosis and repair procedure
Observe the water level. Remove the cistern lid (ceramic lids are heavy and fragile; lay it flat on a towel on the floor, never lean it against the wall). See whether water is spilling into the top of the overflow pipe. If it is, the cause lies with the fill valve and float.
Dye test. If the water level is below the top of the overflow pipe, put a few drops of dye into the cistern, do not flush, and wait about 15–20 minutes. Coloured water appearing in the bowl means the flush valve is leaking.
Shut off the water and empty the cistern. Close the angle stop valve supplying the toilet, flush, and soak up the remaining water with a sponge.
Deal with the fill valve. Lower the float (turn the adjusting screw or slide the clip) so the water level stops about 2–3 cm below the top of the overflow pipe. If the water still rises after lowering it, remove the fill valve cap, rinse out the debris and check the washer; replace the washer or the whole fill valve if worn.
Deal with the flush valve. For a flapper valve with a chain: check whether the chain is too tight or snagged and whether the flapper is warped. For a tower valve: remove the tower (usually by turning it through an angle and lifting it out), check the bottom seal and clean the sealing surface on the valve seat. Replace the seal or the whole tower with the correct code.
Check the refill tube and the push-button mechanism. The refill tube (the small tube from the fill valve into the overflow pipe) must be clipped in the correct position, with its end not pushed down below the water level, to avoid back-siphoning that makes the cistern refill continuously. The push-button linkage must not press on the valve tower when the button is not pressed.
Turn the water back on and re-test. Open the stop valve slowly and watch the float shut off and the water level. Flush both modes several times. Repeat the dye test for 15–20 minutes. Check that every connection under the cistern and the supply hose are not weeping.
Safety: Ceramic cistern lids and bodies are heavy and broken edges are very sharp — wear gloves and lay the lid flat on a towel on the floor. With electronic toilet seats, unplug the power before dismantling and do not let water splash onto the socket or plug. On two-piece toilets, if you have to remove the cistern, tighten the cistern bolts evenly on each side and do not over-tighten, because the ceramic can crack.
Tips when buying parts
Take the old seal or tower with you and photograph the code printed on the valve body, the toilet model and the flush plate.
“Universal” parts can serve as a temporary fix for old toilets, but tell the client that durability and sealing may be worse than with genuine parts.
For concealed in-wall cisterns, only buy parts that match the manufacturer’s frame system.

Figure 2. Inside a flapper-type cistern: a black fill valve, the overflow pipe and a red flush flapper, with a metal lever connected to the handle. Photograph the inside of the cistern like this before going shopping so you choose the right type of part.
Six common causes and how to recognize them
The table below is a common reference for domestic toilet cisterns in homes on mains water or a pump. Dismantling details vary by manufacturer.
Cause | How to recognize it | How to fix it |
|---|---|---|
1. Float set too high | Water spills continuously into the top of the overflow pipe | Lower the float so the water stops about 2–3 cm below the top of the overflow pipe |
2. Fill valve not closing fully | Water still rises after lowering the float, with a hissing sound | Rinse out debris, replace the fill valve washer or the fill valve |
3. Flush valve seal hardened or scaled | Positive dye test; the cistern refills by itself from time to time | Clean the valve seat and replace the seal with the correct code |
4. Chain or push-button mechanism sticking | Must press again or jiggle to stop the water running | Adjust the chain slack, adjust the push-button linkage |
5. Refill tube wrongly placed, causing back-siphoning | The cistern refills by itself even though the flush valve seals | Clip the refill tube in the correct position, with its end above the water level |
6. Water pressure too high | The fill valve does not shut off cleanly and hisses; even a new valve soon leaks | Recommend fitting a pressure-reducing valve or readjusting the booster pump |
Note: cause 6 is common in houses with booster pumps. Do not conclude what pressure is “too high” without measuring with a pressure gauge; measure at the nearest tap and compare with the fixture manufacturer’s recommendations.

Figure 3. A cistern viewed from above: the fill valve and supply pipe at the top, and the flush valve assembly with a chain connected to the handle at the bottom. Sediment on the bottom of the cistern, as in the photo, easily stops the flush valve sealing properly.
Worked case: a cistern that refills every 10 minutes
Situation
An apartment with a one-piece toilet and a dual-button tower flush valve. The client says that at night, about every ten minutes, they hear the cistern refilling for a few seconds. The recent water bills are higher than before even though the number of people has not changed.
Narrowing down and calculating
You open the cistern lid: the water level is about 2.5 cm below the top of the overflow pipe and not spilling over — ruling out causes 1 and 2. Dye test: after 15 minutes, there is a blue streak in the bowl — the flush valve is leaking. The refill tube is clipped in the correct position.
Estimating the water lost: assume each refill is about 0.5 litres, about 6 times per hour; over 24 hours that is 0.5 × 6 × 24 = 72 litres per day, or about 72 × 30 ≈ 2,160 litres, roughly 2.2 m³ per month. This is an illustrative calculation using the assumptions of this case; the real amount depends on the size of the leak.
Solution and re-check
Close the stop valve, empty the cistern and remove the valve tower. The bottom seal has hardened, its edge has a dent, and the valve seat is covered with a layer of scale. You clean the seat with a soft brush (no sandpaper, which would scratch the sealing surface) and replace the seal with the same code you photographed. Turn the water on and repeat the dye test for 20 minutes: no colour in the bowl. Monitor for another 30 minutes: the cistern does not refill by itself. You advise the client to read the water meter before going to bed and the next morning to double-check.

Figure 4. Two flush valve seals next to a ruler (cm): the one on the left is scaled, the one on the right has a cleaner surface. Measure the diameter of the old seal to buy the right size; a hardened or scaled seal is the most common cause. (Photo: Abrev, CC BY-SA 3.0, Wikimedia Commons)
Replacing the fill valve and flush valve: detailed steps
Replacing the fill valve
When you need to replace the whole fill valve, close the stop valve, empty the cistern and dry the bottom. Place a small bucket under the cistern because the supply hose still holds a little water. Undo the supply hose nut at the bottom of the cistern, then the plastic nut holding the fill valve body. Lift out the old valve, clean the mounting hole and check that the ceramic around the hole is free of scale and chips.
Fit the new valve with its supplied washer on the correct side (the washer usually sits inside the cistern), and adjust the height of the valve body if it is adjustable so the top of the valve is above the overflow pipe as specified by the manufacturer. Tighten the plastic nut by hand and then a little more with pliers; do not over-tighten, because both plastic and ceramic crack easily. Refit the supply hose; if the old hose is stiff, rusty or bulging, replace it. Turn the water on, set the float to the correct level and check the bottom of the cistern with a dry towel.
Replacing the flush valve tower
On most one-piece toilets, the tower of the flush valve can be removed without taking off the cistern: turn it through an angle in the direction printed on the body and lift it out. If the whole valve base needs replacing (cracked base or damaged sealing surface), on a two-piece toilet you usually have to remove the cistern from the bowl: shut off the water, disconnect the supply hose, undo the cistern bolts and lift the cistern off, laying it on a towel. Fit the new base, replace the cistern-to-bowl gasket as well, refit and tighten the bolts alternately on each side.
After fitting, adjust the length of the linkage rod or pull cable for the push button so that when the button is released, the valve tower drops fully onto its seat without being held up. Test both the half-flush and full-flush modes and check that both close cleanly.
Final check before replacing the lid
Wait for the cistern to fill, watch the float shut off, check that the water level stops at the correct mark, with no hissing. Place a dry sheet of paper under the cistern and under the supply hose nut for ten minutes to detect small weeps. Replace the cistern lid gently and check that it does not press on the float arm or the push-button linkage.
Common situations
Water seeping onto the floor around the base of the cistern or toilet
This is not a “running toilet” fault but is often confused with one. Check the supply hose, the stop valve nut, the cistern bolts (on two-piece toilets) and the connections under the cistern. Water pooling around the base of the toilet after flushing may be caused by the toilet’s floor seal — review the toilet installation lesson.
Weak flush, needing two flushes
Usually caused by a water level that is too low (float lowered too far) or scale in the outlet or the rim holes of the bowl. Set the float to the correct level before thinking about unblocking.
Concealed in-wall cisterns
Remove the flush plate and the mechanism frame to reach the valves. Do not lever against the plastic frame. If you would have to open up the wall to make the repair, that is a sign you should call the manufacturer’s technician.
Very hard water with lots of sediment
Seals and fill valves will fail again quickly. Recommend a coarse filter at the supply inlet and regular cleaning of the cistern; do not promise “fix it once and it’s fixed forever”.
Common mistakes
Replacing the whole cistern fitting set without testing — symptom — still leaking after the replacement. Cause — the real fault was the pressure or the refill tube. Fix — always check the water level and do a dye test first.
Bending the float arm — symptom — the float touches the cistern wall and shuts off only some of the time. Cause — using an old-style adjustment on a sliding-float valve. Fix — use the valve’s proper adjusting screw or clip.
Sanding the flush valve seat — symptom — a worse leak after the repair. Cause — scratching the sealing surface. Fix — clean only with a soft brush and a mild descaler.
Buying the wrong part — symptom — the seal does not fit tightly, the tower is loose. Cause — not photographing the code. Fix — take the old part with you and photograph the code before buying.
Tightening the cistern bolts unevenly — symptom — leaking at the base of the cistern, or in bad cases cracked ceramic. Cause — over-tightening one side. Fix — tighten alternately on each side a little at a time.
Forgetting to fully reopen the stop valve — symptom — the cistern fills very slowly. Cause — the valve was only partly opened after the repair. Fix — open the stop valve fully and check the time it takes to fill the cistern.
When to stop and call the responsible party: the cistern or toilet body has hairline cracks or leaks from the ceramic itself; the toilet is still under warranty and the client wants to keep the warranty valid; a concealed cistern requires opening the wall; in an apartment building, water is leaking to the floor below or the apartment’s main valve cannot be shut off — inform the building management.

Figure 5. A plastic flush valve flapper that has lost its rubber sealing layer — a type of failure that makes water trickle continuously into the bowl. Take the old flapper with you, or photograph the code printed on the valve body and the toilet model, when buying parts.
Reporting to the client
Record: the cause found, the dye test results before and after, the parts replaced (with codes) and the water level after adjustment. If possible, give an estimate of the water lost with clear assumptions so the client understands why it is worth repairing promptly.
Sample report wording:
“The cistern wasn’t overflowing, but the dye test showed the flush valve seal had hardened, so water was trickling into the bowl and the cistern kept refilling. I cleaned the valve seat and fitted a seal with the same code. A 20-minute dye test after the repair showed no more leakage. Please don’t put cleaning tablets in the cistern, as they can make the seal fail faster; if you hear the cistern refilling by itself again, give me a call to check it.”
Parts and labour prices vary by brand, region and over time. Quote the parts price to the client once you have identified the correct code.
Frequently asked questions
How can I tell whether the toilet is leaking when I can’t see water running?
Put a few drops of food colouring into the cistern, do not flush, and wait about 15–20 minutes. If the water in the bowl becomes coloured, the flush valve is leaking.
What does it mean when water runs into the overflow pipe continuously?
It is usually caused by a float set too high or a fill valve that does not close fully (worn fill valve washer, debris, water pressure too high). Lower the float first; if the water still rises, clean or replace the fill valve.
Do I need to replace the whole cistern fitting set?
Not necessarily. In most cases you only need to adjust the float, or clean or replace the flush valve seal. Replace the whole set when the valve body is cracked, the plastic has become brittle, or parts with the correct code are no longer available.
Should I put chlorine cleaning tablets in the cistern?
It is better not to. Many manufacturers advise against in-cistern cleaning tablets because the chemicals can make rubber seals fail faster. Check the toilet manufacturer’s instructions.
How do I repair a concealed in-wall cistern?
Remove the flush plate on the wall to reach the fill valve and flush valve through the frame. The procedure and parts vary by manufacturer; you need the correct parts for that frame system.
Practice exercises
On a training cistern, adjust the float so the water level stops exactly 2–3 cm below the top of the overflow pipe.
Remove and refit the flush valve tower of a dual-button cistern, naming each component.
Dye-test a cistern with a faulty seal (prepared by the instructor), identify the leak path and repair it.
Set up a situation where the refill tube is pushed below the water level, observe what happens and fix it.
Calculate the monthly water loss from the number of self-refills you count in one hour.
Self-assessment criteria — you pass when you:
Correctly diagnose the leak path (overflow or flush valve) before removing any component.
The water level after the repair is at the correct mark.
A 15–20 minute dye test after the repair shows no colour in the bowl.
There are no leaks at the supply hose or the connections under the cistern.
Your report includes the part codes and the test results before and after.
After this lesson, move on to the lesson on tracing concealed in-wall water leaks in the same step, for when the sanitary fixtures have been ruled out but the water meter is still turning.