A puddle under the household pump is one of the most common call-outs a residential plumber gets. The client says "the pump is leaking" and expects to buy a new one. Often the pump is fine apart from one small part: the mechanical seal (phớt) that stops water escaping along the spinning shaft between the pump body and the motor. Replacing it is a routine bench job, but only after you have proved that the water really comes from the seal, and only with the power isolated and the pressure released.
This guide covers the small surface pumps found in Vietnamese homes (self-priming pumps, single-impeller centrifugal pumps and booster pumps on pressure tanks): confirming the leak, understanding why seals fail, isolating and dismantling the pump, choosing the right replacement, fitting it without damaging it, and testing.
Scope and safety. Written for residential plumbers in Vietnam and experienced homeowners working on small single-phase surface pumps (230 V/50 Hz). It does not cover submersible or borehole pumps, three-phase pumps or pumps under warranty, which should go back to the supplier. A pump that hums but will not start, runs without delivering water, or switches on and off constantly has its own guide. Figures marked for reference are rough working examples, not rules from a standard or a manufacturer. Never open a pump that is still plugged in or under pressure. If water has reached the motor, the terminal box, the capacitor or the wiring, do not switch it back on: electrical checks and repairs must be done by a qualified electrician.
Step 1: Understand what the mechanical seal does
Where the motor shaft passes into the water chamber, a seal must let the shaft spin while keeping the water in. In almost every modern domestic pump this is a mechanical seal with two parts:
The rotating part (seal head) sits on the shaft behind the impeller and turns with it: a face ring (often carbon or ceramic), a rubber bellows or sleeve gripping the shaft, and a spring pressing the face forward.
The stationary part (seat) is a hard ring (often ceramic or silicon carbide) held in a rubber cup or O-ring and pressed into the back plate between the pump chamber and the motor.
The two polished faces press together, and a very thin film of water between them lubricates and cools them. When the faces are scratched, cracked, burnt or held apart by dirt, or the rubber has hardened, water passes along the shaft and drips out between the pump and the motor.
Some older or larger pumps use gland packing (braided rings squeezed by a gland nut) instead, which is designed to drip slightly and can be adjusted. A mechanical seal cannot be adjusted; once it leaks steadily it must be replaced.

Figure 1. A domestic jet pump cut open lengthways to show its inside: the pump body (cut faces painted yellow), the impeller and the jet passages (cut edges in orange-red) and, behind the impeller, the shaft seal with its coiled spring on the motor shaft, just in front of the motor. The pump sits on a blue pressure tank. Brand labels have been blurred. Any leak at the seal comes out at the gap between the pump body and the motor. (Photo: Pierre5018, Wikimedia Commons, CC BY-SA 4.0)
Step 2: Confirm where the water is coming from
Many "seal leaks" turn out to be something else. Ten minutes of observation can save a needless strip-down.
Dry the pump and watch
Wipe the pump, the pipes and the base completely dry.
Lay dry tissue or newspaper under the pump so the first drops show clearly.
Watch the pump while it runs and while it stands still under pressure (pressure tank full, taps closed). Use a torch and, in tight spaces, a small mirror.
Find the highest wet point. Water runs along pipes and bodies, so where it drips is often not where it leaks.
Typical leak points
Shaft seal: water appears at the gap or small drain hole between the pump body and the motor, under the shaft line, and runs down the bracket to the base. It is often worse while running or just after starting. Rust streaks or white scale on the motor end show it has been going on for a while.
Threaded fittings: water forms at the inlet or outlet joint, a union, the non-return valve or the pressure switch connection.
Casing gasket or O-ring: a wet line around the joint between the two halves of the pump body, often at one bolt.
Drain or priming plugs: water around a plug only; a worn washer or cracked plastic plug.
Cracked casing: a hairline crack, often near an over-tightened fitting; cast iron may show a rust line.
Condensation: in humid weather cold water makes the pump and pipes "sweat". Fine droplets cover large areas evenly, including pipes away from the pump, with no single source. No repair is needed, only better ventilation.
Something above: a tank fitting or pipe joint overhead dripping onto the pump. Look up.
Has the leak reached the motor?
Rust or scale on the motor side of the bracket, water in or around the terminal box, a residual current device (RCD/ELCB, aptomat chống giật) that trips, or bearings that now rumble all mean the job is more than a seal. Keep the pump off and have an electrician check the motor before it is ever switched on again.
Step 3: Understand why the seal failed
A seal replaced without finding the cause often fails again. Ask what happened before the leak started.
Dry running. A pump running with an empty cistern, a lost prime, a closed inlet valve or an air lock has no water to cool the faces and can damage its seal very quickly. Burnt, glazed or cracked faces are typical.
Sediment and sand. Grit from wells or sludgy cisterns scratches the faces.
Scale and deposits. Hard or iron-rich water builds up on the seal and shaft and stops the faces closing.
Heat. Long running against a closed outlet, a very hot pump room, or hot water with a seal not meant for it.
Wear and age, especially on pumps that start and stop many times a day.
Wrong installation. Dirty or touched faces, grease on the faces, a crooked seat, the wrong size, a missing spacer or a scratched shaft.
Worn bearings that let the shaft wobble.
Keep the old seal and look at it in good light: burnt or cracked faces point to dry running, fine scratches to sediment, crusts to scale.
Step 4: Isolate the pump safely
A small pump is still a 230 V appliance sitting next to water, and a booster set holds water under pressure.
Switch off and unplug. Turn off the pump's circuit breaker and unplug it, or switch off the isolator. If the pump is wired into a pressure switch or controller, switch off the breaker that feeds it.
Lock out and label. Tape the breaker off with a note ("Pump under repair – do not switch on") and tell the household. If you cannot lock it, keep the plug with you.
Confirm it is dead. A competent person confirms with a proper tester that there is no voltage at the pump.
Close the valves on the suction side and the outlet side.
Release the pressure. On a booster set, open a nearby tap or the tank drain until the flow stops and any gauge reads zero. Leave the air valve on the pressure tank alone; it holds the air pre-charge.
Mind the capacitor. Single-phase pumps have a capacitor that can hold a charge after the power is off. Do not open the terminal box or touch its terminals; disconnecting wiring is an electrician's job.
Let it cool. A pump that has run dry can burn your hands.
If the pump comes out for bench work, put a bucket under the unions, undo them and mark which pipe was the inlet.
Step 5: Dismantle the pump
Models differ, so use the maker's manual if you have it and photograph each step.
Remove the pump body
Draw a pen line across the pump body and motor so the outlet points the same way on reassembly.
Undo the body bolts a little at a time in a criss-cross order.
Separate the motor and impeller from the body. On many small pumps the motor, back plate and impeller pull out together, leaving the body on the pipework. Remove the old casing O-ring or gasket.
Remove the impeller
The impeller is usually screwed onto a threaded shaft end or held by a nut, often with a key. To undo it, stop the shaft turning:
Many small motors have a screwdriver slot in the shaft end under the fan cover.
Some shafts have flats for a thin spanner.
Do not wedge a screwdriver into the impeller vanes or fan blades; plastic and brass impellers crack or bend easily.
Check the thread direction before forcing anything. Threaded impellers are normally fitted so that the motor's rotation tightens them, so the undoing direction depends on the pump. Look at the rotation arrow, check the manual, and try gently both ways. A rusted impeller can be freed with penetrating fluid on the thread and patience; clean everything thoroughly before the new seal goes on.
Remove the old seal
Rotating part: pull it off the shaft with a slight twist, or ease it with two small blades from opposite sides without scratching the shaft.
Spacers: note any washer or shim between the seal and the impeller; it sets the spring pressure and must go back in the same place.
Seat: if the back plate comes off, press the seat out from the motor side with a blunt tool such as a wooden dowel; otherwise lever it out carefully from the front without damaging the bore.
Clean and inspect
Seat bore: remove rust, scale and old rubber until it is smooth and round, using a cloth, a plastic scraper and, if needed, very fine abrasive paper used lightly. No grooves.
Shaft: polish light corrosion where the seal head sits. Deep pitting or a groove means the new seal may leak along the shaft; the shaft or motor needs specialist repair.
Bearings: the shaft should spin smoothly with no grinding and no noticeable sideways play. Rough or loose bearings are a job for a motor repairer.
Impeller and body: clean out debris and check for cracks.

Figure 2. The cast-iron housing of a small pump on a workbench after rust and mineral deposits have been scraped and brushed off, with screwdrivers, a ratchet and a wire brush beside it. A pale ring sits in the bore at the centre, apparently the stationary seat of the shaft seal. The uploader notes that some pitting remained but the pump sealed well once reassembled; the seat bore itself must be smooth and clean. (Photo: Oldforgefarm, Wikimedia Commons, public domain)
Step 6: Identify the right replacement seal
Seals come in many sizes and designs, and "nearly the same" usually leaks. Always replace the rotating part and the seat as a matched set.
Shaft diameter at the seal position, measured with a caliper away from worn areas.
Seat outside diameter (with its rubber cup or O-ring) and its height.
Seal head length uncompressed, and its spring type (conical, straight, rubber bellows).
Seat type: rubber cup, O-ring, L-shaped and so on.
Face materials, for example carbon against ceramic, or harder pairs for gritty water. Tell the shop if the pump handles hot water.
Pump nameplate details (make, model, serial) and the maker's part number if the manual gives one.
Seal shops in Vietnam often sort seals by series codes and sizes. Take the old seal, the old seat and your measurements to the shop and compare the new parts side by side before you pay. If in doubt, the maker's spare part is the safe choice. Buy a new casing O-ring or gasket at the same time.

Figure 3. Cutaway drawing of a single mechanical seal on a shaft (9). According to the original key: (1) set screw, (2) and (6) O-rings, (3) and (8) pins that stop the rings turning, (4) the rotating seal ring, (5) the stationary counter-ring, (7) the housing wall, shown only in outline, and (10) springs. The sealing happens where ring (4) presses against ring (5). Seals in small household pumps are usually simpler, with one spring and a rubber bellows, but they work in the same way. (Drawing: Silberwolf, Wikimedia Commons, CC BY-SA 2.5)
Step 7: Fit the new seal
The faces are lapped extremely flat. A fingerprint, a speck of grit or a smear of grease can make a new seal leak.
Clean hands, clean bench. Keep the seal in its packing until needed.
Do not touch the faces. Handle parts by their edges and rubber. If a face gets dirty, clean it as the seal maker recommends (often a lint-free cloth and a suitable solvent such as isopropyl alcohol) and let it dry.
Lubricate only the rubber, and only with water. Wet the seat's rubber cup, the inside of the bellows and the shaft with clean or slightly soapy water. No oil or grease on the faces; mineral oil can also damage some rubbers. Use another lubricant only if the seal maker allows it.
Press in the seat. The polished face points towards the impeller. Press it squarely into the clean bore with even thumb pressure or through a clean plastic tube or the cardboard disc from the packaging. It must sit flat, not tilted.
Fit the seal head onto the shaft, face towards the seat, with a gentle twist. Some designs are compressed by the impeller as it is tightened; others have a set screw or fixed position. Follow the seal instructions.
Refit spacers and impeller exactly as they came out. Hold the shaft and tighten firmly without overtightening plastic or brass impellers.
Turn the shaft by hand. Slightly stiffer than before is normal; rubbing or scraping is not.
Step 8: Reassemble, prime and test
Fit a new casing O-ring or gasket, seated in its groove without twisting.
Refit the body on your pen mark and tighten the bolts evenly, criss-cross.
Reconnect the pipework with fresh thread seal and refit the drain plug with a sound washer.
Prime the pump. Fill the body through the priming plug until it overflows, turning the shaft slightly to release air; on suction lifts the suction pipe must be full too. Never run the pump dry to "test" it.
Open the valves, suction side first.
Restore power. Remove the lock and label. If any wiring was disconnected, the electrician reconnects and checks it first.
Run and watch. Run with a tap open, then let it build pressure and stop. Check the seal area, casing joint, plugs and fittings with dry tissue.
Check again after the pump has cycled for a while, for example 15–30 minutes of normal use (for reference), and ask the client to look the next day.
What about a small weep?
A new seal sometimes weeps a little during its first minutes of running while the faces bed in. It should reduce and stop quickly; follow the seal maker's guidance. A steady or growing drip is not normal: isolate the pump again and look for a dirty or damaged face, a crooked seat, a missing spacer or a damaged shaft.
Step 9: Prevent the next failure
Most household seal failures come back to dry running and dirty water.
Dry-run protection: a float switch in the cistern or tank stops the pump when the water gets low. On booster pumps, a controller or pressure switch with a low-pressure or no-flow cut-out does a similar job. Wiring these in is an electrician's job.
Strainers: fit or clean the strainer on the foot valve or suction line, and keep the suction end off the cistern floor.
Clean cisterns and tanks regularly.
Correct operation: do not run the pump against closed valves, and fix suction-side air leaks that make it lose its prime.
A dry, ventilated position, out of rain and standing water, with a regular glance underneath for early weeping.

Figure 4. A cable float switch: a red plastic float on a black cable with a black weight, lying on a table. Hung in a cistern or tank, the float tips as the water level changes and switches the pump circuit, so the pump stops before it can run dry. Markings on the float have been blurred. Connecting a float switch to the pump circuit is electrical work. (Photo: S.J. de Waard, Wikimedia Commons, CC BY 2.5)
Reference table: leak sources, checks and fixes
Where the water appears | Likely source | Quick check | Fix |
|---|---|---|---|
Gap or drain hole between pump body and motor, worse when running | Worn or damaged mechanical seal | Dry the pump, watch with tissue underneath, running and standing | Replace seal head and seat as a set; find the cause |
Joint around the middle of the pump body | Casing O-ring or gasket | Wet line around the joint | New O-ring or gasket; tighten bolts evenly |
Inlet or outlet connection, unions | Thread joint or union washer | Dry tissue around each joint | Remake the joint |
Around a plug on the pump body | Plug washer or cracked plug | Wet around the plug only | New washer or plug |
Thin line on the body, rust trace | Cracked casing | Close look in good light after drying | Replace pump body or pump |
Fine droplets all over pump and pipes in humid weather | Condensation | No single source | No repair; improve ventilation |
Drips onto the pump from above | Tank, pipe or fitting overhead | Look up | Repair the source above |
Rust on motor side, RCD trips, noisy bearings | Leak has reached the motor | Visual check only, pump kept off | Electrician checks motor before restart; then seal and bearings |
Practical examples
Example 1: The booster pump that "sweated"
Every morning there was water under a booster pump in a closed space under the stairs. The pump and nearby cold pipes were wet all over, with no drip point. Dried and watched running, the seal area stayed dry: it was condensation. A vent and a drip tray solved it without touching the pump.
Example 2: Dry running after a water cut
After a long supply cut, a self-priming pump on a cistern ran dry before anyone noticed, and a few days later it dripped between the pump and motor. The seal faces were glazed, one with a fine crack. The plumber fitted a matched new seal and casing O-ring, primed the pump, and recommended a float switch, which an electrician connected.
Example 3: A new seal that leaked the same day
A homeowner's DIY seal dripped from the first start. The seat had been pressed in at a slight angle and the faces greased "to help it slide". The plumber fitted another new seal, wetting only the rubber with soapy water and seating it squarely. It wept for a few minutes, then stayed dry.
Safety checklist
Breaker off and pump unplugged or isolated; breaker locked or taped and labelled.
No voltage confirmed at the pump by a competent person with a proper tester.
Household told not to touch the breaker.
Suction and outlet valves closed.
Pressure released (gauge at zero, taps no longer flowing).
Terminal box and capacitor left closed; electrical work left to an electrician.
Pump cool enough to handle; bench clean and dry.
No oil or grease on the seal faces.
Pump primed with water before the first start.
If water reached the motor or the RCD tripped: pump kept off until an electrician has checked it.
Frequently Asked Questions
Can I tighten the seal to stop the leak?
No. A mechanical seal has nothing to tighten. Only gland packing has an adjustable nut, and even that is designed to drip slightly.
Can I stop the leak with sealant or tape?
No. The leak is between the two faces inside the pump, where sealant cannot reach. It only hides the problem while water works its way towards the motor.
Do I have to replace both parts of the seal?
Yes. The faces wear together, and a new face against an old seat will usually leak.
How long should a pump seal last?
There is no fixed figure. It depends on seal quality, running hours and starts, water cleanliness, temperature and, above all, whether the pump ever runs dry.
Is it worth replacing the seal on an old pump?
Often yes, as the seal is a small part. But if the bearings are rough, the shaft badly corroded or water has reached the windings, the whole repair may not be worth it. Explain the options and let the client decide.
Practice Exercises
Leak hunt. On a working pump, dry everything, lay tissue underneath and watch it running and standing under pressure. Record where the first drop appears and which table row it matches.
Bench strip-down. On an old pump with the power cord removed, dismantle the body, impeller and seal, photographing each step, then reassemble it.
Read the old seal. Describe the faces and rubber of a used seal and suggest what caused the failure.
Shopping list. Measure a shaft, seat and seal head and write the list a seal shop would need.
Safety briefing. Write the isolation steps for a booster pump on a pressure tank as a checklist for a new apprentice.
Client conversation. Write a short, plain reply to a client who asks why you cannot "just put some glue on it".