A dripping shower set is one of the most common call-outs for a residential plumber in Vietnam. The client says "the shower leaks", but on site that can mean five different faults: the shower head dripping after the mixer is closed, a spray from a hose nut, a damp patch under the wall mixer, water running down the wall behind the cover plates, or the bath spout and the shower running at the same time.
This guide follows a typical Vietnamese shower set from the wall outwards, shows how to trace a leak to one joint or one part, and explains how to repair it with washers, PTFE tape, a new cartridge or a new diverter, and when to replace the whole mixer.
Scope and safety. This article covers exposed wall-mounted shower and bath-shower mixers ("củ sen") with a hose and hand shower, as fitted in most Vietnamese homes. Concealed (in-wall) valves are mentioned only briefly. Sizes and times given here are typical values for reference; the manufacturer's instructions always take priority. Learners should work under the supervision of an experienced plumber.
How a typical shower set is put together
From the wall outwards, these are the joints where water can escape:
Two wall outlets. The hot and cold supply pipes (usually PPR) end in threaded female fittings set at the finished tile surface. They belong to the concealed pipework, not to the mixer.
Two eccentric S-unions ("chân sen lệch tâm" or "cút lệch tâm"). One end screws into the wall outlet; the other end, offset from the first, carries the mixer nut. Turning the unions adjusts the distance between the mixer inlets and levels the mixer when the wall outlets are not perfectly placed. A chrome cover plate slides over each union to hide the wall thread.
The mixer body, held on the unions by two nuts, each sealed with a flat rubber washer.
The control parts: a ceramic disc cartridge in single-lever mixers, or two headworks in two-handle mixers.
A diverter on bath-shower mixers, sending water to either the spout or the shower: a push-pull knob, a rotating knob or a button.
The shower hose, with a nut and flat washer at each end.
The hand shower and its holder: a wall bracket or an adjustable holder on a slide rail.
On most shower sets sold in Vietnam these connections use the 1/2-inch British pipe size, marked G1/2 (a parallel thread): the wall outlets, the unions, the mixer's shower outlet, both hose nuts and the hand-shower connection. This is the usual rule, not a guarantee. Some imported or designer sets use other sizes or special connectors, so always compare the old and new part before buying.

Figure 1. A hand shower on a slide-rail holder, with its hose connected to a wall outlet elbow. The holder itself carries no water; leaks at this point come from the hand-shower connection or the hose nuts. (Photo: AJ Ahamad, Pexels, Pexels License)
Shut off the water and make it safe
Every repair below starts the same way:
Find the right valve. Many bathrooms have no stop valve for the shower. Use the bathroom branch valve, the rooftop tank outlet valve or the main valve after the meter. For the hot line, also close the water heater's cold inlet valve.
Switch off an electric storage water heater ("bình nóng lạnh") at its circuit breaker before working on the hot line. Do not work next to a live appliance while its water is being disturbed.
Let the hot water cool. Water straight from a heater can scald. Run the hot side to the drain until it runs cool before opening any hot joint.
Release the pressure. With the supply closed, open the mixer on hot and cold, in both diverter positions, until it stops running.
Cover the drain and lay a towel in the shower tray to catch small parts and protect the tiles.
Step 1: Ask, look and dry before you touch anything
Ask the client: Does it leak only while the shower runs, or also when everything is closed? Only on hot, or on both? Since when? Was anything replaced recently?
Dry everything, then wrap dry tissue around each joint in turn while the water runs; tissue shows a slow weep that eyes miss on wet chrome.
Test in a fixed order:
Everything closed (supply open, mixer off): watch the head and spout for a minute or two, then check the wall below the mixer.
Shower on cold, then on hot: check the hose nuts, the hand shower, the lever and the mixer nuts.
Diverter to spout, then to shower: check that only one outlet runs at a time.
Note which joint is wet in which test; this usually points to the fault.
Step 2: Leaks at the hose and the hand shower
Drip or spray from the hose nuts
Water from the nut at either end of the hose almost always means a faulty flat rubber washer: hardened, cracked, squashed out of shape, or missing after a hose change.
Unscrew the nut by hand, or with an adjustable spanner padded with a cloth so the chrome is not marked.
Inspect the washer. Replace it if it is hard, flat, cracked or deformed.
Clean the end of the outlet and the seat inside the nut; grit or old tape on the sealing face will leak even with a new washer.
Fit a new washer of the same type. Some hand-shower ends use a washer with a filter screen; replace like with like.
Screw the nut on by hand until it grips the washer, then a little more by hand or with a light turn of the spanner.
Do not wrap PTFE tape on a washer-sealed joint. The hose nut seals where the washer presses on the end of the outlet, not on the threads. Tape there does nothing useful and can stop the nut seating squarely.

Figure 2. A new shower hose with 1/2-inch nuts at both ends and the black flat rubber washer that makes the seal. The washer, not the thread, stops the water, so hose nuts do not need PTFE tape. (Photo: Ich, Wikimedia Commons, CC BY-SA 4.0; label details blurred)
Water seeping along the hose
Water along the hose, or where the metal sheath meets an end fitting, means the inner tube has split or pulled out of its fitting. This cannot be repaired: replace the hose with one of the same thread and a suitable length. Advise the client not to kink the hose.
Drips from the hand shower itself
Water between the head and the handle, or around a spray-mode button: internal seals have failed. Most hand showers are not designed to be taken apart, so replace it.
Cracked plastic thread on the handle: usually from over-tightening a metal hose nut. Replace the hand shower and tighten the new one gently.
A few drops from the face plate just after closing the mixer: water draining from the hose and head. This is normal. A drip that goes on and on means water is passing the mixer (Step 4).
The holder
A holder or slide rail carries no water, so it cannot leak. Water "from the holder" is dripping from the hand shower or hose nut above it. A worn swivel can let the head droop and spray the wall, and a loose bracket may need re-fixing. Before drilling tile, find out where the pipes run: the pipes to the mixer and to any overhead shower are hidden in the wall, often directly above or below the outlets. Ask for pre-tiling photos and avoid drilling in line with the outlets.
Step 3: Leaks at the wall unions and cover plates
Water running down the wall under the mixer, or from behind the cover plates, points to the eccentric unions. Slide the cover plates away from the wall, dry the area, run the water and watch. Each union has two possible leak points.
Leak at the mixer nut
If water appears where the mixer nut meets the union, the flat washer in that nut is worn or crushed.
Shut off and release the pressure.
Support the mixer and undo both nuts with a padded spanner. Lift the mixer off.
Replace both washers; they are the same age.
Clean the union faces, refit the mixer and tighten the two nuts evenly, a little at a time on each side, so the mixer sits straight and both washers are compressed equally.
Leak at the wall thread
If water comes out around the union where it enters the wall, the thread seal has failed. Treat this seriously: water may also be running inside the wall.
Remove the mixer as above.
Photograph or pencil-mark the position of each union.
Unscrew the union, counting the turns.
Clean all old tape from the male thread and loose fibres from the female thread.
Re-tape (see the PTFE section) and screw the union back to the marked position.
Offer up the mixer to check the centre distance and level before fitting the cover plates.
A rule for eccentric unions: finish by turning the union forward into position. Backing a taped thread out by a large amount to reach the right angle loosens the tape and is a common cause of slow leaks. If you overshoot a lot, take it out, re-tape and try again.
If the wall outlet itself is cracked, stripped, or set so deep that the union cannot reach it properly, the job becomes a pipework repair behind the tile, not a mixer repair.
Step 4: Water passing the mixer when it is closed
A steady drip from the shower head or spout after the mixer is fully closed means water is passing the shut-off parts inside the body.
Single-lever mixers: the ceramic disc cartridge
Most modern mixers in Vietnam use a ceramic disc cartridge: two very hard, very flat ceramic discs slide over each other. The lever moves the upper disc to uncover more or less of the hot and cold inlet holes; in the closed position both holes are blocked.
A cartridge stops sealing when sand, rust or scale scratches the discs (common after pipe work), when its base seals harden, or with age. A stiff, rough or loose lever is another sign of wear.

Figure 3. How a ceramic disc cartridge works (German labels): Hebelbefestigung = lever mount; bewegliche Ventilplatte = moving disc; feststehende Ventilsitzplatte = fixed seat disc; Kaltzulauf / Warmzulauf = cold / hot inlet; gemischter Ablauf = mixed outlet; aus, warm, wärmer, heiss = off, warm, warmer, hot. If grit scratches the two discs, water passes even in the 'off' position. (Diagram: Cschirp, Wikimedia Commons, CC BY-SA 3.0)
To replace the cartridge:
Shut off hot and cold, switch off the water heater and release the pressure.
Remove the lever: usually a screw under the red-and-blue cap, or a grub screw needing a small hex key.
Unscrew the chrome shroud over the cartridge, if there is one.
Undo the brass retaining nut with a correctly sized spanner while holding the body steady, so you do not twist it on its unions.
Pull the cartridge straight out and note its position; most have locating lugs that fit holes in the body.
Take it to the shop. Match diameter, height, spindle shape, spline count and base, not just the "size". Common single-lever sizes are 35 mm and 40 mm, for reference only.
Clean the seat with a soft cloth. Never scrape the sealing faces with a screwdriver.
Fit the new cartridge with its lugs located and its base seals in place, and tighten the nut firmly but not excessively; over-tightening can stiffen the lever or crack the cartridge.
Refit the shroud and lever, open the supply slowly and test.
If a new cartridge starts passing again soon, look for debris: clean any strainers or filter screens upstream and flush the pipes before fitting another one.
Two-handle mixers: headworks
Quarter-turn handles usually have ceramic headworks; replace the faulty one with a matching headwork.
Handles that turn several times usually have compression headworks with a rubber washer on a spindle. Replace the washer; if the drip soon returns, the brass seat is probably damaged.
To find the faulty side, close the hot and cold supplies one at a time. If the drip stops when the hot supply is closed, the hot side is passing.
Thermostatic bar mixers
These have a thermostatic cartridge and a separate flow control, with parts specific to each make and model. Use the manufacturer's instructions and genuine parts, and do not alter the maximum-temperature stop beyond what the instructions allow; it is part of the scald protection.
A worn cartridge can also let hot and cold water cross inside the mixer, so a cold tap elsewhere may run warm. Test by closing one supply at a time. Weak flow, by contrast, is usually a blockage or supply problem rather than a leak; see our separate guide to diagnosing low water pressure at home.
Step 5: The diverter
A worn diverter on a bath-shower mixer gives two typical symptoms:
The spout keeps running while the shower is on: the diverter seal is worn, or scale stops it closing fully.
The knob drops back while the water is still running: the seal or spring is worn. (Many push-pull diverters are designed to drop back when the water is turned off; that is normal.)
On many exposed mixers the diverter unscrews as a unit, and new O-rings or a replacement diverter can be fitted. Shut off and release the pressure, note the order of the parts, clean scale from the bore gently, and lubricate new O-rings only with silicone grease suitable for drinking-water fittings. Never use petroleum grease on rubber seals; it makes many rubbers swell. If the diverter is built into the body and no spare exists, the mixer must be replaced.

Figure 4. A cut-open bath-shower valve body. Hot and cold water meet in the mixing device; the diverter valve (here set to shower) then sends the mixed water either up to the shower or down to the tub spout. A worn diverter seal lets water reach both outlets at once. This example is a concealed valve, but exposed bath-shower mixers work on the same principle. (Photo: Christoph Roser at AllAboutLean.com, Wikimedia Commons, CC BY-SA 4.0)
PTFE tape: where it belongs and how to use it
PTFE tape ("băng tan", also called "cao su non") belongs on the wall threads of the eccentric unions, not on joints that seal with a flat washer.
Make sure the male thread is clean and dry.
Looking at the end of the thread, wrap clockwise, the same direction the fitting turns as it screws in. Wrapped the other way, the tape unwinds.
Start one thread back from the end so loose tape cannot hang into the bore, and keep it flat and slightly stretched so it sinks into the threads.
Too little tape weeps; too much can stop the union reaching its position or strain the female fitting. Follow the practice of your supervising plumber and the tape maker's guidance on the number of turns.
Screw in by hand first, then finish with a padded spanner.

Figure 5. PTFE tape being wound onto a male thread; wrap it in the direction the fitting turns as it screws in. On a shower set, this belongs on the wall threads of the eccentric unions, not on washer-sealed hose nuts. (Photo: NA, Wikimedia Commons, public domain)
Step 6: Leak test after the repair
Check every nut and washer, then dry all joints.
Open the supply slowly; a sudden surge can push a washer out of place.
With the mixer closed, check every joint with tissue for a minute or two.
Run the shower on cold, then hot, and switch the diverter both ways, checking again.
Close the mixer and watch the head and spout for at least ten minutes (for reference). A few draining drops are normal; a steady drip is not.
Switch the water heater back on only after the hot line is full and air has been purged at the mixer.
Refit the cover plates. After a wall-thread repair, ask the client to watch the wall below the mixer for a day or two.
When to replace the whole mixer
Replace rather than repair when:
The body is cracked, porous (weeping through the casting) or badly corroded where the seals sit.
No matching cartridge, headwork or diverter can be found.
Threads on the body or outlets are damaged, or the chrome is peeling over corroded brass.
Several parts have failed and the repair cost approaches that of a new mixer of similar quality.
The client wants an upgrade, such as a thermostatic mixer for better scald protection.
Check that the new mixer's inlet centres can be met by the existing unions, or that it comes with new unions. Replace worn unions and washers at the same time.
Reference table: symptom, likely cause, fix and parts
Symptom | Likely cause | Fix | Parts |
|---|---|---|---|
Spray or drip at a hose nut while running | Hard, cracked or missing flat washer | Replace washer, clean seats, hand-tight plus a little | 1/2" flat shower washer |
Water along the hose or at its end fitting | Split inner tube or failed crimp | Replace hose | Hose with matching threads |
Leak from the hand-shower body or button | Internal seal failure | Replace hand shower | Hand shower |
Water at the mixer nuts | Crushed or aged washer | Remove mixer, replace both washers, tighten evenly | 1/2" flat washers |
Water from the wall behind a cover plate | Failed union thread seal, or damaged wall outlet | Re-tape and refit union; repair outlet if damaged | PTFE tape; S-union pair |
Steady drip from head or spout with mixer closed | Worn or scratched cartridge or headwork | Replace it; clean strainers | Matching cartridge or headwork |
Spout runs while showering | Worn diverter seal or scale | Service or replace diverter | O-rings or diverter unit |
Lever stiff, rough or loose | Worn cartridge | Replace cartridge | Matching cartridge |
Damp wall under the mixer, no visible drips | Union wall thread or concealed pipe | Test unions first, then pressure-test concealed pipes | Depends on cause |
Practical examples
Example 1: The hose that was "too tight". In a rented flat, the shower spurted at the bottom of the hose. The previous tenant had wrapped thick PTFE tape round the mixer outlet and tightened the hose nut with pliers, crushing the washer into a thin, cracked ring. Removing the tape, fitting a new washer and tightening by hand plus a quarter turn stopped the leak.
Example 2: The drip that came back. A single-lever mixer began dripping a few weeks after pipe repairs in the house. A new cartridge stopped it, but only for days. The filter screen in the hot line turned out to be packed with sand from the repair. After cleaning the screen, flushing both lines and fitting another cartridge, the drip did not return.
Example 3: The damp tile. A tile under a mixer was always damp, but no drip was visible. With the cover plates off and the area dried, a bead of water formed at the hot union's wall thread whenever hot water was used. The union had been turned back during installation to level the mixer. After making the hot line safe, the plumber re-taped the union, turned it forward to the marked position and refitted the mixer with new washers. The wall dried within days.
Safety checklist
Shut off the supply and release the pressure before opening any joint.
Switch off the electric water heater at its breaker before working on the hot line; switch it on again only when the line is refilled and purged.
Let hot water cool before opening a hot joint; heater water can scald.
Do not overtighten chrome or plastic fittings: padded spanner only, no pliers or pipe wrench on chrome, never force a plastic thread.
Before drilling tile, check where hidden pipes run and avoid drilling in line with the mixer outlets.
Use only parts and lubricants suitable for drinking-water fittings.
Leak-test every joint before you leave and tell the client what to watch for.
Frequently Asked Questions
Is it normal for the shower head to drip after I turn it off?
A few drops for a minute or two are normal: water is draining from the hose and head. A drip that continues for many minutes, or all night, means water is passing the mixer, usually through a worn cartridge or headwork.
Should I use PTFE tape on the shower hose threads?
No. Hose nuts seal on a flat rubber washer; if they leak, replace the washer and clean the seats. PTFE tape is for the wall threads of the eccentric unions.
What size are shower hose and mixer threads in Vietnam?
On most sets they are 1/2-inch British pipe threads, marked G1/2. Some products use other sizes, so compare the old and new parts before buying.
How do I know which cartridge to buy?
Take the old one to the shop and match its diameter, height, spindle and splines, and base. Buying from a dealer who stocks the mixer maker's spare parts is safest.
Water comes out of the wall, but the mixer joints are dry. What now?
Remove the cover plates and test the union wall threads. If they are dry too, the leak is in the concealed pipework: pressure-test the hot and cold pipes separately to find which one leaks before any tile is removed.
Practice Exercises
Exercise 1: Read the symptoms. A client says water drips from the shower head all night. With the supply open and the mixer closed, the drip is steady; when you close the hot supply, it stops. What is the likely fault, and what will you check and replace?
Exercise 2: Plan the shut-off. A bathroom has no shower stop valve. The house has a rooftop tank, a meter with a main valve and an electric storage heater. List, in order, the steps to make the hot line safe before removing the mixer.
Exercise 3: Wrap a union. On a practice board, tape an eccentric union, screw it into a 1/2-inch female fitting, and set it to a marked position by turning forward only. Pressure-test the joint and inspect it for weeps.