"I replaced the angle valve under the basin myself and wrapped half a roll of PTFE tape on it, but it still drips." Leaks at threaded joints are one of the faults plumbers see most often, both on new installations and during repairs. Most of the time the cause is not poor fittings but tape wrapped in the wrong direction, in the wrong place, with the wrong number of turns, or tightened the wrong way, or PTFE tape applied to a joint that is supposed to be sealed by a washer.
This lesson teaches the technique of sealing threaded water pipe joints in detail. By the end of this lesson, you will be able to tell which joints need PTFE tape and which are sealed by a washer; wrap in the correct direction with the correct number of layers; choose between PTFE tape, thread sealant paste and sealing cord; tighten just enough on brass and plastic threads; and fix a leaking threaded joint in the correct order. For replacing a whole valve assembly, see the lesson Main shut-off and isolating valves leaking or seized; for concealed leaks in walls whose location is not yet known, see Finding concealed leaks in walls without breaking them open.
What is PTFE tape and why do threaded joints need it?
In Vietnam plumbers call it "cao su non" (literally "soft rubber"), but it is really thread seal tape, i.e. PTFE tape (also called Teflon tape or plumber's tape). It is not rubber at all, but a thin, white, soft, slippery, non-sticky film of PTFE plastic. The most common type on the market is about 12 mm wide (for reference; thickness and density vary by product and are usually printed on the packaging).
Even well-cut pipe threads leave small gaps between the crests and roots of the threads. Water under pressure will creep out along that spiral path. PTFE tape does two jobs:
It fills the gap between the two sets of threads when they are pressed together, blocking the spiral path for water.
It lubricates, so the threads screw in deeper and more smoothly, with less risk of binding or stripping.
The key point: PTFE tape only works on joints that seal on the thread itself, where the further the threads screw in, the tighter they press together. On joints with a washer, sealing is the washer's job, not the thread's.
Tapered threads and threads with washers: tell them apart before wrapping
In domestic water supply you will come across two kinds of threaded joint:
Self-sealing threaded joints (usually tapered threads)
The thread narrows slightly towards the end; the more you screw it in, the tighter the male and female threads press together. Examples: the tail of an angle valve into the threaded outlet in the wall, the body of a wall-mounted tap, hex nipples, elbows, threaded tees, the main valve body. This is where you use PTFE tape or thread sealant.
Joints sealed by a washer (usually parallel threads with a seating face)
The thread only draws the two faces together; the water is stopped by a flat washer or an O-ring clamped between the two seating faces. Examples: the nut on a flexible supply hose, the end of a shower hose, a washing machine inlet hose, the face of a union, a cap with a washer. Here you do not wrap PTFE tape onto the washer or the seating face. If it leaks, check the washer (missing, misaligned, hardened, torn) and the seating face (scratched, chipped, dirty).

Figure 1. A ball valve with a green lever handle and a male-threaded outlet; the metal cap is open, hanging from a small metal strap, with a black flat washer inside the cap. On this type of joint it is the washer pressing against the end face that does the sealing, so PTFE tape is not needed. (Photo: BlackEyedLion, Wikimedia Commons, CC BY-SA 4.0)
If you are not sure which type a fitting is, read the documentation that comes with it or ask the supplier. Two threads of different standards may screw together for a few turns without fully engaging; don't try to force them with lots of tape.
Reference table: what seals each joint
Joint location | Main sealing method | Wrap PTFE tape? | Notes |
|---|---|---|---|
Angle valve tail into the threaded outlet in the wall | Thread | Yes | Wrap the valve tail thread; don't let tape protrude into the bore of the pipe |
Flexible supply hose nut onto the angle valve or the tap | Washer inside the nut | No | Check that the washer is present, flat and not misaligned |
Offset (S-union) legs of a hot and cold shower mixer into the wall | Thread | Yes | The other end of the offset leg into the mixer body is usually sealed by a washer |
Washing machine inlet hose | Washer | No | Mainly hand-tighten; see the washing machine installation lesson |
Union | Washer or a conical face in the middle | Don't wrap the union face | The two threaded ends joining onto the pipe are wrapped like normal threads |
Hex nipples, elbows, tees, threaded brass valves or galvanised pipe | Thread | Yes | Use two spanners when tightening |
PPR or uPVC fittings with threaded ends | Thread | Yes | Mainly hand-tighten; be careful not to crack plastic fittings |
Water meter threads, pipe before the meter | Belongs to the water utility | Don't handle it yourself | Report it to the water utility |
Reference table: common thread sizes and suggested number of turns
In Vietnam plumbers usually refer to pipe sizes by outside diameter ("phi 21", "phi 27", i.e. 21 mm, 27 mm...), while threads are named in inches. The table below is for quick cross-reference; the number of turns is only a guide for the common thin tape and also depends on the tape thickness, how loose the thread is and the fitting manufacturer's instructions.
Pipe size as plumbers call it | Thread size | Nominal size | Turns of PTFE tape (guide) |
|---|---|---|---|
21 mm | 1/2" | DN15 | About 4 to 6 turns |
27 mm | 3/4" | DN20 | About 5 to 7 turns |
34 mm | 1" | DN25 | About 6 to 8 turns |
42 mm | 1 1/4" | DN32 | More; test-fit to adjust |
49 mm | 1 1/2" | DN40 | More; test-fit to adjust |
The correct result: the tape fills the roots of the thread but the thread shape is still visible. If the thread disappears under a bulky layer of tape, there is too much; if metal shows between the turns, there is too little. In practice, you should be able to screw it in by hand for a few turns of thread before you need a spanner; if it goes almost all the way in by hand, the tape is too thin or the thread is worn.
Preparation before you start
Shut off the water and release the pressure: close the branch valve or the main valve, open a lower tap to release the pressure and drain some of the water from that section of pipe. Never undo a threaded joint while the pipe is still under pressure.
Hot water branches: switch off the water heater's circuit breaker (MCB) and wait for the water to cool before undoing anything.
Tools: PTFE tape suitable for domestic water; two spanners or adjustable wrenches and water pump pliers to hold against the turning force; a small wire brush and a pointed scriber; rags, a bucket, a torch and tissue paper. On chrome-plated fittings, put a rag in the jaws of the wrench to avoid scratching.
A 7-step process for wrapping PTFE tape and fitting a threaded joint leak-free the first time
Step 1. Clean and inspect the threads
Scrape off all old tape and old sealant from the male thread and inside the female thread. Brush along the thread grooves with the wire brush, and pick out tape stuck in the thread roots with the scriber. Wipe dry; leave no oil, grease, sand or metal filings on the thread. Inspect closely: stripped, chipped or worn-flat threads; hairline cracks on plastic threaded ends; longitudinal cracks on brass fittings. If the thread is damaged or the fitting is cracked, replace it; don't compensate by wrapping more tape.
Step 2. Test-fit without tape
Screw the male thread into the female thread by hand, with nothing wrapped on it. It should go in smoothly without cross-threading. If it gets stiff after only half a turn, the thread standards may not match or the thread may be damaged: stop and check.
Step 3. Work out the wrapping direction
Hold the fitting so that the end of the male thread is pointing towards your face. For a standard right-hand thread (turned clockwise to tighten), wrap the PTFE tape clockwise when viewed from the end like this. In other words, the tape is wrapped in the same direction as the female fitting screws on.
If you wrap the wrong way, when you screw the parts together the female thread "strips" the tape off and bunches it up at the end of the thread, and the joint leaks no matter how much you wrapped. This is a common mistake among beginners.

Figure 2. PTFE tape being wrapped onto the male thread of a chrome-plated connector attached to a valve with a light green handle; above it is a chrome-plated fitting with a female thread waiting to be screwed on, and below is the roll of tape in a blue case. The tape is pulled taut so it hugs the thread grooves. (Photo: NA, uploaded by Nagao, Wikimedia Commons, public domain)
Step 4. Wrap taut, overlap the edges, leave the first thread clear
Place the start of the tape on the first or second thread from the end of the pipe. Many plumbers leave the first thread bare: it makes it easier to start the thread when screwing in and reduces the chance of tape fragments getting into the bore, where they travel with the water and jam tap cartridges, aerator screens and float valves.
Hold the end of the tape with your thumb and pull it moderately taut so the tape thins out and sinks into the thread grooves. Slack tape will bunch up as you screw in.
Wrap in a spiral working towards the base of the thread, each turn overlapping the previous one by about half the width of the tape.
Wrap the required number of turns (see the reference table), finish towards the base of the thread, snap the tape off and smooth the loose end down in the wrapping direction.
Gently smooth the whole wrap with your finger in the wrapping direction so the tape presses into the thread grooves. Check again: the thread shape is still visible, there are no gaps and no large folds.

Figure 3. The smaller male thread of a nickel-plated reducing adaptor neatly wrapped in white PTFE tape: the tape covers all the thread turns, but the thread shape is still clearly visible; the larger thread below has not been wrapped yet. When you do it yourself, leave the first thread at the end of the pipe clear so tape fragments don't get inside. (Photo: Pece, Wikimedia Commons, CC BY 3.0, cropped)
Step 5. Hand-tighten first, then use a spanner, and always hold against the turning force
Screw in by hand until hand-tight. If it won't go in a single turn, take it out and remove some tape.
Use a spanner to tighten further. For metal fittings, the usual amount is about 1 to 2 turns beyond hand-tight (for reference; follow the manufacturer's instructions if available). For plastic fittings with plastic threads, mostly hand-tighten, adding just a little with a tool if needed, and avoid long-handled spanners.
Always use a second spanner to hold the opposite fitting (valve body, tee, elbow). Without holding against it, the twisting force is transmitted back, turning the whole section of pipe, loosening threaded joints further back, or twisting off or cracking a joint buried in the wall.
Take special care with threaded outlets on PPR pipe in the wall (elbows or tees with a brass female insert moulded into the plastic): overtightening can make the brass insert turn inside the plastic or crack the plastic around the insert. The crack sits behind the tiles, water seeps out slowly, and it only shows up weeks later.
Step 6. Adjust the position: never back off
Many fixtures need to end up facing the right way after tightening: the offset legs of a shower mixer must be level on both sides, an angle valve's handle must face outwards, a tap must be vertical. Only adjust by tightening further to the correct position, never by backing off. Backing off even slightly loosens the tape and the joint will easily leak.
If tightening further would make it too tight before it reaches the right position: take it apart, add or remove one or two turns of tape, and refit. For places that need to be taken apart regularly, consider using a union.
Step 7. Turn the water on slowly and check for leaks
Close the taps you opened earlier, and open the branch valve slowly so water and air flow through gently.
Wipe the threaded joint completely dry. Wrap a piece of dry tissue paper around the joint or place paper underneath it: if the paper gets a wet patch, there is a leak, even if you can't yet see a drop.
Check straight away, then again after about 15 to 30 minutes (for reference). On new installations, before plastering and tiling, pressure-test the whole run following the procedure in the lesson Installing hot and cold water supply lines and pressure testing before plastering.
Hot water branch: only switch the water heater's circuit breaker back on once the hot tap runs steadily with no air left.

Figure 4. A galvanised threaded pipe wrapped with PTFE tape at both ends, one end screwed into a galvanised elbow: at the edge of the elbow only a thin rim of white tape is visible, while the threaded end on the other side still has its white tape wrap waiting to be fitted. (Photo: Miya.m, Wikimedia Commons, CC BY-SA 3.0)
PTFE tape, thread sealant or sealing cord: how to choose?
Material | Advantages | Limitations | Best for |
|---|---|---|---|
PTFE tape (thread seal tape) | Cheap, clean, easy to carry, easy to take apart again, withstands domestic hot water | Easy to get the direction or number of turns wrong; cannot make up for damaged threads | Most small-diameter domestic water supply threads |
Liquid or paste thread sealant (including anaerobic types that harden in the absence of air) | Fills threads well, depends less on wrapping skill, some types allow adjustment for a short time | Must cure as instructed; many types are for metal threads only; harder to take apart | Metal threads; choose a product clearly labelled for drinking water |
Thread sealing cord (cord type, or hemp fibre with a sealing compound) | Copes with coarse or slightly loose threads; can be adjusted within the limits the manufacturer allows | Must be wrapped with the correct technique; traditional hemp needs an accompanying sealing compound | Large metal threads, coarse threads |
Three principles when choosing:
Domestic and drinking water: only use products the manufacturer clearly states are suitable for domestic and drinking water.
Plastic threads: use PTFE tape or a sealant clearly labelled as suitable for plastics. Some sealants and jointing compounds contain solvents or ingredients that can make plastic brittle and crack over time. If unsure, use PTFE tape.
Don't mix at random: don't wrap tape and also smear on sealant unless the sealant's instructions allow it.
Gas pipework is outside the scope of this lesson; leave gas joints to a qualified gas fitter.
A threaded joint that is already leaking: deal with it in order
1. Find exactly where it is leaking
Wipe the whole assembly dry, wait a few minutes, then trace it with tissue paper from the top down; the place where you see drops is usually lower than the real leak. Distinguish between:
A leak at the base of the thread, between two fittings: a thread sealing fault.
A leak at the flexible hose nut or a union: a washer or seating face fault.
A leak at the valve stem or handle: a fault in the valve's internal seal, not the threaded joint.
A leak from the body of the fitting: usually a crack, so it must be replaced.
A cold pipe wet evenly along its whole length in humid weather: it may be condensation, not a leak. Wrap paper at a point away from the joint to compare.
2. Try tightening a little more (only on metal threads in good condition)
A newly fitted metal threaded joint with a very slight leak: you can tighten a little more (about 1/8 to 1/4 of a turn, for reference), holding against the turning force. If that doesn't stop it, or the thread is already screwed in deep, or it is a plastic thread or a PPR threaded outlet: stop tightening and redo the joint. Forcing it can easily turn a leaking joint into a broken fitting.
3. Take it apart, clean it and redo it from scratch
Shut off the water, release the pressure, undo the threaded joint and "read" the old tape: tape bunched up at one end means it was wrapped in the wrong direction; thin tape with metal showing means too little was wrapped; torn tape and misaligned threads mean the thread was cross-threaded. Clean it, inspect the threads, then redo it from Step 1 to Step 7.
4. "Quick fixes" you should not do
Wrapping extra PTFE tape around the outside of a fitted threaded joint: tape on the outside does nothing to seal it.
Smearing silicone or two-part epoxy (AB glue) over a leaking thread and handing over: it may slow the leak for a few days, but it won't last under pressure, and it makes the next repair harder.
Real examples from the job
Case 1. A basin angle valve the client replaced themselves, wrapped very thickly but still leaking
The client replaced the angle valve themselves and wrapped nearly ten turns of tape, yet the valve tail still dripped. When it was taken apart, the tape was bunched into a lump at the end of the thread and the rest of the thread was almost bare: it had been wrapped in the wrong direction. The plumber cleaned the thread, rewrapped it in the correct direction with a moderate number of turns, screwed it in by hand and then tightened further while holding against the turning force. The valve stopped leaking, and the handle ended up facing the right way without backing off.
Case 2. A crooked shower mixer, with one offset leg leaking
The previous plumber had backed off the hot-side offset leg to level the shower mixer, and after that it leaked every time someone took a hot shower. The plumber shut off the water, switched off the power to the water heater, removed the offset leg, cleaned the thread, test-fitted it dry to see where the leg would stop, and then adjusted the number of turns of tape so that when tightened fully the two legs were level. The end of the offset leg that goes into the mixer body is sealed by a washer, so only the washer was replaced.
Case 3. A washing machine tap overtightened, water seeping out through the wall
A month after a washing machine tap was fitted into a concealed PPR threaded outlet, the wall around the tap became damp and the paint started peeling. When the tap was removed and inspected with a torch, the plastic around the brass insert was cracked, because during fitting a long-handled spanner had been used to tighten it hard, braced against the wall. The tiles had to be chiselled open, the damaged section cut out and a new PPR fitting welded in (see the lesson Welding PPR pipe correctly), pressure-tested and only then finished again. The lesson: tighten threaded outlets in the wall just enough, with the right number of turns of tape, and never force them.
Safety checklist
Shut off the water and release the pressure before undoing any threaded joint; never undo it while the pipe is still under pressure.
Working on a hot branch: switch off the water heater's circuit breaker, wait for the water to cool, and wear gloves when undoing joints that are still hot.
Working near sockets, pumps, water heaters or washing machines: disconnect the power to the relevant equipment and shield it so water can't splash onto it.
Wear safety glasses when brushing threads with a wire brush and when working face-up under pipes.
Tighten while holding against the turning force; don't overtighten plastic threads or PPR threaded outlets; don't use walls or tiles as a brace for your spanner.
When using sealants or jointing compounds: read the label, wear gloves and ventilate as the manufacturer instructs; choose products suitable for domestic water.
Don't interfere with the water meter or the pipe before the meter, which belong to the water utility; don't work on gas pipe joints.
Clean up tape fragments and metal filings; flush the water through before refitting the tap's aerator screen.
Frequently asked questions
How many turns of PTFE tape are enough?
There is no single number for every case. For a 1/2" thread (21 mm pipe) and the common thin tape, many plumbers wrap about 4 to 6 turns (for reference). The correct result is: the tape fills the roots of the thread but the thread shape is still visible, and it screws in by hand for a few turns before you need a spanner.
Which direction should PTFE tape be wrapped?
Looking at the end of the male thread, wrap clockwise for a standard right-hand thread, i.e. in the same direction as the female fitting screws on. For a left-hand thread (rare in domestic water supply) do the opposite.
I've tightened past the right position. Is it OK to back it off a little?
Backing off loosens the tape, so the threaded joint is likely to leak, especially under pressure. The correct way is to take it apart, change the number of turns of tape and refit it so that it reaches the right position when fully tightened.
Can PTFE tape be used on plastic threads?
Yes, and it is usually the safe choice for plastic threads. The thing to watch is not to wrap it too thickly and not to tighten hard with a spanner, because a plastic female thread can crack when a metal male thread is forced into it.
Practical exercises
Identify the joints: walk around the bathroom and kitchen in your own home or at your placement, list every joint and note clearly which ones are sealed by the thread and which by a washer.
Right and wrong wrapping: on a brass hex nipple and a threaded elbow, wrap once in the correct direction and once in the wrong direction, screw them together and take them apart again to compare the tape. Take photos of both cases.
Position adjustment: fit an angle valve into a threaded elbow so the handle stops facing the right way without backing off; record the number of turns of tape on the successful attempt.
Role-play: the client says "it's only a little leak, just smear some glue on it to be quick." In 1 minute, explain why it should be taken apart and redone, and what the client needs to know about cost and time.