A client calls because the toilet "keeps running". Sometimes it is a constant hiss from the cistern; sometimes the toilet refills by itself for a few seconds every half hour, even at night. Either way, clean water is going down the drain and the water bill rises.
A running toilet is one of the most common plumbing call-outs, and the fault is almost always in one of two parts inside the cistern: the flush valve that lets water out into the bowl, or the fill valve (inlet valve) that lets water in. This guide shows trainee plumbers in Vietnam how to work out which one is at fault, how to adjust or repair it, and when to replace the valve kit instead. It covers lever-and-flapper cisterns and the dual-flush push-button cisterns found in most Vietnamese homes, on both mains-pressure and rooftop-tank gravity supply.
Scope and safety. This article covers the fill valve and flush valve inside a visible ceramic cistern (close-coupled or one-piece toilet). It does not cover concealed in-wall cisterns, sensor or electronic flushes, replacing the angle stop valve, or removing and refitting the toilet. Ceramic lids and cisterns are heavy and break easily, and broken ceramic cuts deeply. The bowl is not clean: wear gloves and wash your hands afterwards. Trainees should do this work under the supervision of an experienced plumber. All figures here are for reference only; the toilet and valve manufacturers' instructions always come first.
How a cistern works, in one minute
Every gravity cistern follows the same cycle:
Flush. The lever or button lifts the flush valve (a rubber flapper, or a "drop valve" with a rubber seal in push-button cisterns) and water rushes into the bowl.
Close. As the cistern empties, the flapper or drop valve falls back and seals the outlet.
Refill. The float drops with the water, opening the fill valve. On many valves a small refill tube also sends some water down the overflow tube to top up the water seal in the bowl.
Shut off. The float rises with the water and closes the fill valve at the set level.
Safety overflow. If the fill valve fails to close, water spills into the overflow tube and drains into the bowl. This stops the bathroom flooding, but it is also why a failed fill valve can run silently for months.

Figure 1. A gravity cistern at rest. 1 float, 2 fill valve, 3 lift arm, 4 tank fill tube, 5 bowl refill tube, 6 flush valve flapper, 7 overflow tube, 8 flush handle, 9 chain, 10 water line, 11 fill valve shaft, 12 flush tube. Push-button cisterns use a drop valve instead of the flapper, but the fill valve, float and overflow work the same way. (Photo: Klork, Wikimedia Commons, CC BY-SA 3.0)
So a toilet runs for only two reasons: water is leaving through the flush valve when it should be sealed, or water is entering and going over the overflow because the fill valve does not shut off. Your first job is to find out which.
Before you start
Bring gloves, rags, a sponge, a small bucket, a torch, food colouring or a dye tablet, a pencil, spanners and a flat screwdriver. Identify the valves before buying parts; sizes differ between makers.
Removing the lid. A lever cistern lid simply lifts off. On many dual-flush cisterns the button passes through the lid, and you must first unscrew the button ring or pull the button out (the method depends on the model). Never force it. Lay the lid flat on a folded towel where it cannot be knocked over.
Check the stop valve. Confirm that the angle stop valve behind the toilet actually shuts the water off. If it is seized or leaks when turned, use the main stop valve and treat the angle valve as a separate repair.
Step 1: Look and listen, then check the overflow
Lift the lid and watch for a minute or two:
Where is the water level? Below the top of the overflow tube, level with it, or spilling into it?
Is the fill valve running now? You will hear a hiss and see water entering.
Is water moving in the bowl? A thin stream or ripples means water is leaving the cistern.
How often does it happen? Ask the client: constant hiss, or short refills now and then?
Many cisterns have a water line mark ("WL" or a moulded line) on the wall or on the overflow tube. Without a mark, a common guide is about 2–3 cm below the top of the overflow (for reference only).
If water is at the top of the overflow and spilling in, the fill valve is not shutting off. Go to the fill valve section.
If the level is clearly below the overflow but the cistern still refills by itself, water is almost always leaving through the flush valve. To confirm, turn off the stop valve, draw a pencil line at the water surface and wait 15–30 minutes (for reference). If the level drops and nobody has flushed, water is escaping. Usually it is the flush valve; rarely it is a crack or a leaking cistern bolt or cistern-to-bowl seal, so check the outside of the cistern and the floor too.
Step 2: The dye test for flush valve leaks
The dye test reveals leaks too slow to see.
With the cistern full and the fill valve stopped, add a few drops of food colouring or a dye tablet to the cistern, not the bowl. Do not flush.
Wait at least 15–30 minutes (for reference; longer for a very slow leak).
If coloured water appears in the bowl, the flush valve is leaking.
Flush afterwards and rinse any dye off the cistern walls.
A quick alternative: wipe the back of the bowl dry under the rim and press dry toilet paper there. If it gets wet within a few minutes, water is trickling in.
Fixing a lever and flapper flush valve
The cover photo shows this type of valve opened up: the flapper lifted off its seat, the chain that lifts it, and the overflow tube beside it.
Chain length. The chain needs a little slack when the flapper is closed, typically one or two links (for reference). Too short, and it holds the flapper slightly open; too long, and it can get trapped under the flapper. Move the clip to another link and cut off any excess that could catch.
The flapper. With the water off and the cistern empty, run a gloved finger round the flapper and seat. A flapper that is hard, warped, swollen, slimy or cracked will not seal; replace it with one that matches the seat (take the old one to the shop). On flappers with a plastic frame and a rubber face, a worn-through face cannot seal at all. Many manufacturers warn that strong in-cistern cleaning tablets, especially chlorine-based ones, can damage rubber parts.
The seat. Feel for scale, grit or chips. Clean scale gently with a non-scratch pad. A cracked or badly pitted seat means the flush valve must be replaced.
The lever. It must return fully after flushing. A sticky handle, or an arm rubbing on the lid or fill valve, can hold the flapper up.
Fixing a dual-flush push-button flush valve
Most toilets sold in Vietnam today have a dual-flush push-button cistern. Instead of a flapper there is a vertical drop valve. Pressing a button lifts the valve body off its seat for a half or full flush, and it falls back under its own weight. The overflow is usually a central tube built into the valve itself.

Figure 2. A close-coupled toilet with a dual-flush push button in the cistern lid, the type found in most Vietnamese homes. The two buttons work a drop valve inside the cistern through rods, so a lid refitted out of position can hold the valve slightly open. Image cropped and brand name removed. (Photo: Eugenio Hansen, OFS, Wikimedia Commons, CC BY-SA 3.0)
Button and linkage
Check this first. Press each button and release: both must spring back fully. The buttons act on the valve through rods, pins or a cable. If the rods are too long or the lid sits slightly out of position, the button can hold the valve a fraction open. The tell-tale sign is a trickle that stops with the lid off and starts again with the lid on. Most designs allow the rod length or button height to be adjusted (follow that model's instructions); leave a small gap between rod and valve at rest.
The drop-valve seal
The seal is a rubber ring at the bottom of the valve body, pressing onto the outlet seat. Over time it hardens, collects scale, or traps grit.
Turn off the stop valve, flush, and sponge out the remaining water.
Remove the valve body. On many drop valves the upper part twists out of a base frame or releases with a clip, so you can reach the seal without removing the cistern. Others are not designed to come apart this way; check before forcing anything.
Replace a seal that is hard, flattened, cracked, deformed or coated in slime or scale with the correct part for that valve.
Clean the outlet seat with a soft cloth or non-scratch pad, checking for grit, sand or chips.
Refit the valve body exactly as it came out, turn the water on and check that it seats.

Figure 3. A used flush valve seal (left) next to a new one (right) over a centimetre scale. The old seal is coated with residue and no longer seals cleanly. Seals for different valve systems differ slightly in size, so take the old one with you when buying a replacement. (Photo: Abrev, Wikimedia Commons, CC BY-SA 3.0)
Some drop valves also have sliders or floats that set the half and full flush volumes. These rarely cause running, but if they have been disturbed, return them to the manufacturer's range so the flush still clears the bowl.
Fixing the fill valve (inlet valve)
If water is going over the overflow, the fill valve is not shutting off. Work from the simplest adjustment to the most involved repair.

Figure 4. A side-entry fill valve with a float cup. As the water rises, the float lifts and closes the valve; the rod sets the float height and therefore the water level. Bottom-entry valves work the same way. (Photo: Cschirp, Wikimedia Commons, CC BY-SA 3.0)
Float height
Turn the water back on after a flush and watch the valve close. If it only closes once water is already at or over the overflow, the float is set too high.
Float-cup valves (float slides on the valve body) usually have a threaded rod, clip or screw that sets the height.
Float-arm (ballcock) valves have a float on an arm; plastic arms usually have an adjusting screw.
Lower the float a little at a time until the water stops at the water line mark, well below the overflow. Let the cistern refill completely after each adjustment.
Float problems
Rubbing or catching on the cistern wall, the flush valve or the button linkage. The float must move freely over its whole travel.
Waterlogged float. A float with water inside sits too low and cannot close the valve. Shake it; if you hear water, replace the float or the valve.
Wrongly fitted after a previous repair. Check it is the right way up and in the correct position.
Debris and worn seals inside the valve
If the float is set correctly but water still enters with the float fully up, the valve is not sealing internally, usually because of grit on the seal or a worn washer or diaphragm.
Turn off the stop valve and open the valve top following the manufacturer's method (often a twist-off cap or a screw).
Clean out any grit, and clean the inlet filter screen if there is one.
Where the design allows, hold a cup over the open valve and briefly open the stop valve to flush debris from the supply pipe into the cistern.
Refit, or replace the seal, diaphragm or whole valve.
Debris is common after pipe repairs, tank cleaning and in new buildings.
Supply pressure: mains and rooftop tanks
Mains pressure or a booster pump. High or fluctuating pressure can stop a worn valve shutting off cleanly and can cause noise and water hammer. Check that the fill valve is rated for that supply (the pressure range is usually on the packaging or instructions). A running toilet can also make a booster pump cycle, so ask whether the pump starts by itself.
Gravity from a rooftop tank. Pressure can be low, especially on the top floor. Some fill valves are designed for low pressure; others need a minimum pressure to work properly. A valve that fills very slowly or does not close firmly may be the wrong type for the supply.
The refill tube
On lever cisterns with a separate overflow tube, the refill tube should be clipped so its end sits above the top of the overflow. If it has been pushed down into the overflow below the water line, it can siphon water out continuously, and the fill valve keeps topping up. Clip it back. On many dual-flush valves the refill feature is built in.
Slow leak or constant hiss?
The pattern of running points to the cause:
Short refill every few minutes or hours, level below the overflow: a slow flush valve leak. Water seeps into the bowl until the level drops enough to open the fill valve. Confirm with the dye test.
Constant hiss, level at or over the overflow: the fill valve is not shutting off.
Constant hiss, level well below the overflow, water flowing into the bowl: a large flush valve leak, such as a missing seal, a jammed button or a flapper caught on its chain.
Reference table: symptom, likely cause, test and fix
Symptom | Likely cause | Test or check | Typical fix |
|---|---|---|---|
Water flowing into the overflow tube | Float set too high | Watch where the level stops; compare with the WL mark | Lower the float to the mark |
Overflowing, float cannot rise freely | Float rubbing on parts or the wall | Move the float by hand | Reposition the float or valve |
Water still enters with float fully up | Grit on seal, worn washer or diaphragm | Open valve top; check seal and filter screen | Clean, flush supply, replace seal or valve |
Short refills at intervals, level below overflow | Flush valve leak | Dye test; pencil line on water level | Clean seat; replace flapper or drop-valve seal |
Trickle in bowl only with the lid on | Button rods too long or lid misaligned | Compare lid on and lid off | Adjust rods or button; refit lid correctly |
Runs until the handle is jiggled | Chain too short or caught; sticky lever | Watch chain and flapper during a flush | Adjust chain slack; free the lever |
Refill tube end inside the overflow | Siphoning | Check where the tube ends | Clip the tube above the overflow |
Level drops, dye test negative | Cistern bolts, cistern-to-bowl seal, crack | Check outside of cistern and floor | Separate repair; do not ignore it |
Very slow refill | Low pressure, stop valve part closed, blocked screen | Check valve, screen and pressure | Open valve, clean, or fit a suitable valve |
When to replace the whole valve kit
Consider replacing the fill valve, the flush valve or both when plastic parts are brittle or have broken clips, the rubber parts are hard and no longer sold for that model, the fault returns after cleaning and adjusting, or the client prefers to renew old valves once rather than call you back.
Before buying, note whether the inlet enters from the bottom or the side and its thread size, the cistern height and water line position, and for drop valves the outlet hole diameter and the size and position of the button hole in the lid. The safest choice is the toilet manufacturer's own kit; if you use a "universal" kit, check that the button fits the lid and the valve height fits the cistern.
Be clear about the size of the job. On many close-coupled toilets, replacing the flush valve base means removing the cistern from the bowl and renewing the cistern-to-bowl seal and bolts, which takes longer, and old bolts may be seized. On some one-piece toilets access is very limited. Tell the client before you start. After fitting new valves, set the water level, flush several times, repeat the dye test and check every connection underneath for drips.
Working with clients
Explain simply and show the evidence: "This seal is worn, so water leaks into the bowl and the cistern keeps topping up." Show them the old part.
Give options: a seal or adjustment now, or a new valve kit, and let them decide.
Teach the meter check: with all taps closed, the water meter should not move. With a rooftop tank, a pump starting when nobody is using water is a similar warning.
Leave it clean and recorded: wipe up spills, take away old parts, and note the parts replaced and test results.
Worked examples
Example 1: Constant hiss in an apartment
An apartment on mains pressure has a toilet that hisses constantly. Water is spilling into the central overflow of the dual-flush valve. The float of a recently fitted fill valve is at its highest setting. The trainee lowers the float until the water stops at the WL mark, about 2 cm below the overflow top. After three test flushes the level stops at the same height and the cistern is silent.
Example 2: The toilet that refills at night
In a townhouse fed from a rooftop tank, the toilet refills briefly "every half hour or so" and the pump runs more than it used to. The level is below the overflow, so the trainee does a dye test; after 20 minutes colour appears in the bowl. With the water off, the drop valve twists out of its base: the seal is hard, with a ring of scale and sand on its face. The trainee cleans the seat, fits the correct new seal and repeats the dye test, and the bowl stays clear. He also cleans the fill valve's inlet screen, which was half blocked with sand from the tank.
Example 3: It only leaks with the lid on
After a bathroom clean, a toilet starts trickling. With the lid off the bowl is still; with the lid on, a thin stream appears. The lid has been refitted slightly turned and one button rod is pressing on the valve. The trainee refits the lid, adjusts the rod to leave a small gap at rest, and checks that both buttons spring back.
Safety and hygiene checklist
Gloves on; the bowl and rim carry germs even when they look clean.
Ceramic lid laid flat on a towel where it cannot fall.
Stop valve confirmed to shut off before any part is removed.
No forcing of ceramic parts and no overtightening of cistern nuts; a cracked cistern is replaced, not patched.
No harsh chemicals on rubber parts unless the manufacturer permits them.
Spilled water mopped up; old parts and dirty rags bagged and removed.
Inlet connection and underside of the cistern checked for drips after the repair, then dried so any new drip is easy to see.
Hands washed thoroughly at the end.
Frequently Asked Questions
Why does my toilet refill by itself every so often?
Usually water is slowly leaking from the cistern into the bowl past the flush valve seal. When the level drops far enough, the fill valve tops it up. A dye test confirms it; the usual fix is cleaning the seat and replacing the flapper or drop-valve seal.
Can I bend the float arm to lower the water level?
Bending was a traditional adjustment on old brass arms, but it is imprecise and can crack old parts. Modern plastic valves have an adjusting screw or rod; use that. Never bend a plastic arm.
Can I just turn the stop valve down a little to stop the running?
No. It only slows the leak, makes refilling slow and hides the real fault. Find and fix the cause.
Do I need to remove the cistern to replace a dual-flush seal?
Often not: on many drop valves the valve body twists or clips out so the seal can be reached. If the valve base itself must be replaced, the cistern usually has to come off the bowl. Check the manufacturer's instructions for that model.
Why does a new fill valve fill slowly on the top floor?
With rooftop-tank supply, pressure on the upper floors can be low, and some fill valves need a minimum pressure to work as designed. Check the valve's stated pressure range and choose one suitable for low-pressure supply.
Practice Exercises
Exercise 1: Name the parts. Using Figure 1 or a training cistern, identify the float, fill valve, flush valve, overflow tube and refill tube, and explain in one sentence what each does.
Exercise 2: Dye test. On a training cistern with a deliberately worn seal, carry out a dye test and record how long colour takes to appear. Replace the seal and repeat the test.
Exercise 3: Set the water level. Raise a float until the cistern overflows, then lower it step by step until the level stops at the water line mark. Record how you confirmed the final level.
Exercise 4: Diagnose from the symptom. For each case, say whether you suspect the fill valve or the flush valve, and which test you would do first: (a) constant hiss, level over the overflow; (b) short refill every 40 minutes; (c) trickle only with the lid on.
Exercise 5: Client explanation. Write a short, plain-language explanation for a client of why their toilet keeps running, what you found, and the repair or replacement options.