"Lately our water smells fishy and there's yellow sediment coming out of the taps", or "We haven't flushed the tank for years and want both the rooftop tank and the underground cistern done properly for peace of mind". The job sounds simple — "drain it, scrub it, pump it back up" — but it comes with three big risks: working at height on the roof, entering the confined space of an underground cistern, and using electricity and chemicals next to water.
By the end of this lesson, you will be able to plan a tank flush, isolate equipment, drain sediment without contaminating the pipework, safely scrub rooftop tanks and underground cisterns, know when disinfection is needed and calculate the amount of bleach (Javel water) by volume, and then hand over to the customer after proper checks.
If you need to revise how to install pumps, floats and rooftop tanks, see the lesson Installing pumps, rooftop water tanks and water heaters for townhouses.
Understand the water storage system before flushing
A townhouse usually has two water "stores" connected by a pump:
Underground cistern (or below-ground storage tank): receives mains water from the meter; built of concrete or a precast tank buried under the yard. It has an inspection hatch and a mechanical float valve on the inlet pipe; the pump draws water from here.
Rooftop tank: a stainless steel, plastic or composite tank on the roof. It has a supply pipe from the pump, a mechanical float valve or electric float switch, an outlet pipe down to the house near the bottom, and many models have a bottom drain valve.
Downstream pipework and appliances: water heaters, RO water purifiers, taps. Sediment and chemicals will flow straight into these if they are not isolated.
Sediment comes from mud and rust carried in with mains water, dust, leaves and insects getting in through loose lids, and microbial slime (biofilm) on the tank walls. Sediment settles at the bottom, below the mouth of the outlet pipe to the house, until the water level drops low (water cut, pump failure) and it gets drawn into the pipes.

Safety before you start
Working at height. Only go on the roof when it is dry, not raining and not very windy. Use a sturdy ladder with someone holding the base. On roofs without railings, or with tanks on high stands: wear a full-body harness clipped to a solid anchor point. Never stand on the tank lid, a corrugated metal roof or a tiled roof to reach.
An underground cistern is a confined space. A cistern that has been closed for a long time may be short of oxygen or contain toxic gases that you cannot smell. The rule: work from above the hatch, and do not go down unless absolutely necessary. If you must go down: use forced ventilation, test the air with a gas detector before and during the work, wear a harness with a line to the surface, always have someone standing at the hatch to watch, and never jump in to rescue someone who has collapsed below. Without a gas detector and a helper, do not go down.
Never run an engine inside or right next to the cistern opening. Petrol pumps and generators produce carbon monoxide (CO), which is colourless and odourless and causes asphyxiation very quickly in enclosed spaces.
Electricity next to water. Submersible pumps and pressure washers must be plugged in through a socket or breaker with residual current protection (RCD/RCBO); never leave temporary cable joints lying in puddles. Unplug before lifting a pump or putting your hand into the cistern. Switch off the house's main pump at its circuit breaker (MCB) and hang a sign.
Chemicals. Javel water (chlorine bleach) burns skin and eyes. Wear rubber gloves and safety glasses and mix in a ventilated place. Never mix bleach with acidic cleaners (vinegar, descalers, toilet cleaners) or products containing ammonia: this can release toxic gas.
Personal hygiene. Sludge may contain disease-causing microbes: wear gloves and boots, and wash your hands after work.
Tools and materials to bring
An A-frame or telescopic ladder tall enough, a full-body harness, a hard hat, non-slip shoes.
An electric submersible sludge pump, a flexible discharge hose long enough to reach the drain, a socket with residual current protection; a voltage tester pen.
A long-handled soft plastic-bristle brush and sponges (no metal fibres) for tanks; a stiffer brush for concrete.
Buckets, scoops, a waterproof torch, a ventilation fan; a gas detector if you might have to go down into the cistern.
Rubber gloves, safety glasses, a face mask, boots; bleach that is within its expiry date (read the concentration on the label), a graduated measuring jug.
A colour-comparison residual chlorine test kit or test strips, a tape measure, and a phone to take before and after photos.
Quick reference table: signs, causes and what to do
Sign reported by the customer | Possible cause | What to do |
|---|---|---|
Cloudy water with yellow-brown sediment after a water cut | Sediment at the bottom of the rooftop tank or cistern drawn into the pipes when the water level dropped | Flush the tank and cistern, flush each tap; check the tap aerator screens |
Water smells fishy or muddy | Biofilm on the tank walls, loose lid, water standing for a long time | Scrub; if there are also signs of contamination, disinfect |
Dead insects, rats or lizards found in the tank | Lid not sealed, vent/overflow pipe without a mesh screen | Drain everything, scrub, disinfect; repair the lid, fit mesh screens |
Rainwater or floodwater has got into the cistern | Inspection hatch lower than the yard surface, lid not sealed | Drain, scrub, disinfect; raise the hatch collar and seal it |
Brown rust spots on the walls of a stainless steel tank | Iron deposits, metal objects dropped in, previously scrubbed with steel wool | Scrub with a soft sponge; ask the tank manufacturer for advice |
There is no universal flushing interval; many tank sellers recommend roughly every 6 to 12 months (for reference only), more often if the water carries a lot of sediment or after flooding.
Step 1: Survey the site and agree with the customer
Before the job day, walk around and check:
The route up to the roof, where to attach the harness, and how the tank lid opens.
Where the underground cistern is, and whether the inspection hatch is wide enough to lower a submersible pump and a long-handled brush.
The sludge discharge route: preferably the main drain. Do not discharge strongly chlorinated water into the septic tank, because chlorine can harm the microbes in the tank.
Whether there is a water heater, an RO purifier or a whole-house inlet filter.
Whether the tank manufacturer provides cleaning instructions. Some stainless steel tank manufacturers advise against chlorine-based or acidic cleaners; the manufacturer's instructions take priority.
Agree with the customer on:
How long the water will be off (much longer if disinfecting, because of the soaking time); tell the customer to store some water for temporary use.
The scope: scrubbing only, or disinfection as well (see Step 6).
Any additional damage found (floats, valves, cracks in the cistern) will be quoted separately before repair.
Real-life example
A four-storey house has a stainless steel tank on the roof terrace and an underground cistern under the stairs; the customer reports sediment in the water after a water cut. The survey shows that the cistern lid is a concrete slab lying flush with the yard, with many gaps, so yard water floods in during the rainy season. The plumber proposes: flush both, disinfect the cistern because of the risk of dirty water getting in, and only scrub and rinse the rooftop tank; quote separately for raising the hatch collar and fitting a sealed lid.
Step 2: Isolate the system
Switch off the pump at its circuit breaker and hang a sign. If there is an electric float switch, still switch off the pump's power rather than just pulling the float.
Close the mains supply valve to the cistern (the valve after the meter) if you will be flushing the cistern.
Switch off the water heater's power and close its inlet valve.
Close the inlet valve to the RO purifier and any filters. Chlorine damages RO membranes, and sediment will clog the coarse filter cartridges.
Step 3: Flush the underground cistern first
Do the cistern first and the rooftop tank second: if you do it the other way round, the first pumping will push sediment from the cistern up into the rooftop tank you have just cleaned. The cistern is also usually dirtier, because it receives water directly from the mains and surface water easily gets in.

Pump it dry and remove sludge from above
Open the lid and let the cistern air out for a while; do not put your head deep into the opening.
Press the TEST button on the residual current socket, lower the submersible pump to the bottom on a suspension rope (never by its power cable), and run the discharge hose to the drain.
Pump until the pump starts drawing sludge; use a long-handled brush to scrub the cistern walls and push the sediment towards the pump, rinse, and keep pumping until the water comes out fairly clear.
When the cistern is empty, use a torch to check for cracks, seepage, tree roots, the float valve, and whether any manholes or waste pipes are too close. Take photos, then open the mains valve to refill the cistern so you have clean water to rinse the rooftop tank.

When you absolutely must go down into the cistern
This is confined space work: meet all the conditions in the Safety section (ventilation, continuous gas monitoring, harness, attendant, a rescue plan from outside) and unplug the submersible pump while anyone is down there. If the team does not have the equipment and trained people, tell the customer straight and only do the work that can be done from the opening.
Step 4: Drain the rooftop tank without pushing sediment into the house
A common mistake is opening every tap in the house "to empty the tank quickly": the bottom layer of sediment will run into the pipes and settle in elbows, fittings and tap aerator screens. The right way:
Let the household use water normally until the tank is low (tell them the day before) to make use of the clean water at the top.
Close the outlet valve to the house (the valve at the start of the tank's outlet pipe).
Drain the remainder through the bottom drain valve into the roof drainage gutter if the tank has one. If the tank has no bottom drain valve, use a small submersible pump or a scoop and bucket to remove the last layer of dirty water, and only open the outlet valve to the house once the tank is clean.
Step 5: Scrub stainless steel and plastic rooftop tanks
Most household rooftop tanks are too small to climb into, and you should not climb into them anyway. Work through the lid opening:
Open the lid and use a torch to look for sediment, rust spots, algae, cracks and the float. Take "before" photos.
Use a long-handled soft brush or a sponge to scrub the walls and bottom of the tank, from top to bottom, working round the tank. Rinse with clean water (run the pump for a few seconds from the cleaned cistern, then switch it off) to wash sediment down to the bottom.
Drain the rinse water through the bottom drain valve or scoop it out. Repeat until the rinse water runs clear.
Wipe the inside of the lid, the tank opening and the gasket; check the mesh screens on the vent and overflow pipes.
Notes by material:
Stainless steel tanks: do not use steel wool, wire brushes or sandpaper; iron particles left behind will turn into rust spots. Do not let chlorine or strong acids sit on the tank walls for long; follow the manufacturer's instructions.
Plastic and composite tanks: do not scrape hard with knives or trowels, because this easily scratches the inner layer, and scratches later collect deposits.
Step 6: Disinfect when necessary
Not every flush requires chlorine disinfection. Disinfect when:
There are dead animals or many insects in the tank or cistern.
Rainwater, floodwater or wastewater has got into the cistern; the lid has been left open for a long time.
A water test shows microbial contamination, or the health authority requires it.
For stainless steel tanks, read the manufacturer's recommendations carefully before using chlorine. If the manufacturer does not allow it, only scrub mechanically and rinse thoroughly.
Calculate the volume
Rooftop tank: check the capacity on the tank label (for example 1000 L, 1500 L).
Rectangular cistern: length × width × water depth when full (in m), multiplied by 1000 to get litres. For example, a 2 m × 1.5 m cistern with water 1.2 m deep: 2 × 1.5 × 1.2 = 3.6 m³ = 3600 L.
Round tank: 3.14 × radius × radius × water depth.
Reference table: bleach (Javel water) disinfection doses
Guidance source | Reference dose | Reference contact time | Notes |
|---|---|---|---|
Alberta Health Services (Canada), guidance on disinfecting water storage tanks | 1 L of 5.25% household bleach per 1000 L of tank capacity (about 50 mg/L of chlorine) | At least 6 hours | Run each tap until you smell chlorine; after soaking, drain, refill and run each tap for at least 5 minutes |
CDC (USA), guidance for rainwater cisterns | About 3 cups (about 0.7 L) of 5–6% bleach per 100 gallons (about 380 L) | At least 12 hours | Run each tap until you smell chlorine; drain after soaking |
These two guidelines are for reference only; their doses and times differ. In practice, give priority to the instructions of the tank manufacturer, the water supply company or the local health authority.
Bleach sold in Vietnam comes in various concentrations, so you must read the concentration on the label and convert: amount needed = reference amount × (5.25 ÷ concentration on the label). For example, using the Alberta dose, a 3600 L cistern needs about 3.6 L of 5.25% bleach; if the bottle label shows only half that concentration, you need about twice as much. Do not use scented bleach or bleach containing other detergents.
Method
Fill the tank about a quarter full with clean water, pour in the measured bleach, then keep filling to the top so the incoming water mixes it.
If you also want to disinfect the pipework: with the water heater and purifier still isolated, open each tap in the house in turn until you smell chlorine, then close it.
Close the lid, stick "DISINFECTING – DO NOT USE WATER" notes on the taps, and tell the whole household.
When the contact time is up, drain the chlorinated water to the drain (not into the septic tank, vegetable garden or fish pond), refill with clean water, and run each tap in turn until the chlorine smell is gone.

Step 7: Restore the water supply, check and hand over
Close the bottom drain valve and seal the lids of the cistern and the rooftop tank.
Switch on the pump's breaker and watch that the cistern float valve and rooftop tank float shut off correctly when full. If there are problems with the floats, see the lesson Rooftop water tank overflowing or not filling.
Run each tap, from the top floor down, until the water is clear and the chlorine smell is gone; remove and rinse the tap aerator screens.
Open the water heater inlet valve and run the hot tap until the water flows steadily before switching the heater's power back on. Open the RO purifier last, once the water no longer smells of chlorine, and discard the first filtered water as instructed by the manufacturer.
Check the joints you have worked on for leaks.
Handover inspection table
Item | How to check | Passes when |
|---|---|---|
Clarity | Fill a glass from the top-floor tap and hold it up to a light | Clear, no suspended particles |
Smell, residual chlorine | Smell it; measure with a colour-comparison kit and compare with mains water taken before the cistern | No fishy smell; chlorine similar to the incoming mains water |
Floats, pump | Watch one complete filling cycle | Float valves seal fully, no overflow; pump stops when full |
Lids, mesh screens | Close the lids to test; check the mesh on the vent and overflow pipes | Sealed, mesh intact |
Downstream appliances | Water heater and purifier reopened | Working normally, no leaks |
The permitted residual chlorine level in domestic water is set by the Ministry of Health's technical regulation; when a customer asks for the figure, look up the current document rather than quoting from memory.
Working with the customer at handover
Send "before" and "after" photos and note what you found: how thick the sediment was, whether the lid had gaps, whether the cistern was cracked.
Suggest further work: insect mesh screens, raising the cistern hatch collar, a coarse inlet filter.
Do not promise that the water is "drinkable straight away" based only on sight and smell; if the customer is worried, advise them to have a sample tested by an accredited laboratory.
Safety and quality checklist
☐ Dry weather, no strong wind; sturdy ladder with someone holding it; harness clipped to an anchor point when working on a roof without railings.
☐ Pump breaker switched off and sign hung; water heater power off and inlet valve closed; RO purifier isolated.
☐ Submersible pump plugged into a residual current socket (TEST button checked), hung by rope or chain; no engines running near the cistern opening.
☐ Nobody goes down into the cistern without ventilation, gas testing, a harness and an attendant.
☐ Gloves, glasses and mask worn when mixing bleach; never mixed with acidic or ammonia-based cleaners.
☐ Sludge discharged to the drain, not into the house supply pipes; chlorinated water not discharged into the septic tank, vegetable garden or fish pond.
☐ Stainless steel tanks not scrubbed with steel wool; no chemicals left sitting for long.
☐ Every tap flushed; water heater refilled before switching on; purifier opened last.
☐ Tank and cistern lids sealed; before and after photos taken, additional damage noted for the customer.
Frequently asked questions
Should I add bleach to the tank regularly to keep the water clean?
No. Mains water is already disinfected. Adding bleach regularly yourself makes the water smell and can affect stainless steel tanks and RO purifiers. Only disinfect when there is a reason, after scrubbing off the sediment, and always drain and rinse thoroughly.
My stainless steel tank has brown rust spots inside — does that mean it's poor quality?
Not necessarily. Brown spots may be iron deposits from the mains water, metal particles dropped in during installation, marks from steel wool, or caused by the tank material. Try scrubbing with a soft sponge; if the spots remain, or there are pits or pinholes, take photos and contact the manufacturer or the seller, and do not use acid to remove them yourself.
The cistern is small — is it a problem if I just climb in for a few minutes?
Yes. Toxic gas or lack of oxygen in a closed cistern cannot be seen or smelled; asphyxiation happens very quickly, and anyone who jumps in to help is easily overcome too. Work from the opening; only go down when all the safety conditions above are met.
Practice exercises
Calculate volume and bleach quantity: measure a rectangular cistern or storage container at the workshop, calculate its volume in litres, then calculate the amount of bleach using the Alberta reference dose for a bottle with the concentration printed on its label. Write down your working for your instructor to check.
Plan the isolation: draw the water supply diagram of a sample house (cistern, pump, rooftop tank, water heater, RO purifier, taps) and number the order in which to close valves before flushing and reopen them afterwards.
Safe use of a submersible pump: test the residual current socket's TEST button, hang the pump by a rope in a water container, pump it dry and run the water to the drain.
Customer role-play: one trainee plays a homeowner asking you to "climb into the cistern and scrub it clean, just be quick". Explain the confined-space risks and propose working from the opening.