“The pump is humming away, I can feel it vibrating, but when I open the tap from the rooftop tank there isn’t a drop.” Plumbers get this call a lot in the dry season, especially in homes that use a pump to lift water from an underground tank to a rooftop tank or a pump drawing from a shallow borehole or dug well.
Most of these cases are not caused by a failed motor but by the suction side: the tank or well has run dry; the pump has lost its prime; the strainer or foot valve (non-return valve) is stuck or not sealing; the suction pipe is drawing in air; or the pump is mounted too high above the water level. Less often, the impeller is jammed with debris or worn, or the motor runs slowly because of a weak capacitor. This lesson takes you through the checks in order from easiest to hardest. By the end of this lesson, you will be able to find out why a running pump delivers no water and fix the most common causes safely.
This lesson only covers the case where the pump runs but delivers no water. For booster pumps that keep switching on and off, see Booster pump running continuously or switching on and off repeatedly; for installing a new pump and rooftop tank, see Installing a pump, rooftop water tank and water heater for a townhouse.
Quick understanding: why does a pump spin but not draw water?
Most household water pumps placed above ground are centrifugal pumps: the impeller spins, flings water outwards and creates a low-pressure zone at the suction inlet. It is atmospheric pressure acting on the water surface in the tank or well that pushes water up the suction pipe. This leads to three things to remember:
An impeller spinning in air can hardly draw anything. The pump body and suction pipe must contain water (the prime).
Even a small leak on the suction side is enough to stop the pump drawing. The suction side is at lower pressure than the outside, so a leak sucks air in rather than dripping water out, which makes it very hard to see.
Suction lift is limited. In theory, atmospheric pressure at sea level can only support a water column of about 10 m (for reference); in practice you must subtract losses in the pipe, elbows and strainer, plus the pump’s own limits, so it is considerably less. The figure for each pump must be taken from the rating plate and manual (the “suction lift” or “suction depth” item).
A non-self-priming pump must have a strainer with a foot valve at the end of the suction pipe to hold water in the pipe, and both the pump body and the suction pipe must be filled. A self-priming pump retains water in its body, so after the first priming it can evacuate the air from the suction pipe by itself, but “self-priming” does not mean it can run dry.
Step 0. Isolate the power and observe before touching anything
Switch off the circuit breaker (MCB) feeding the pump and unplug it (if it has a plug). Do not just turn off the switch or the float switch, because the float can close at any moment.
Look around: is there standing water on the floor, are the cables or junction box submerged or cracked? If there are signs of electrical leakage, stop and call an electrician.
If the pump body is very hot, it has been running dry for quite a while; the water left in the pump chamber may be very hot. Let it cool before opening the priming plug, stand to one side and do not put your face close to the plug.
Ask the owner: did it fail suddenly or weaken gradually? Has anyone just repaired the pipes or cleaned the tank? How long has the mains water been off? The answers often point straight to the cause.
This lesson is about pumps that do spin (you can hear the motor running smoothly and the cooling fan turning). If the pump only hums and vibrates without turning, the impeller is usually seized, or there is a problem with the capacitor or windings: switch off immediately, do not keep applying power to test it, and get an electrician. For the principle of capacitors, see the lesson Electric fan not turning, turning weakly or humming.
Step 1. Is there enough water in the tank or well?
Underground tank: open the lid, stand at the opening and shine a torch down from above; do not climb in. The strainer must be fully submerged below the water surface; if the water level is right at the strainer, the pump draws in air as well, creating a vortex, and the water comes up intermittently and then stops. If the tank is empty because the mains water has not arrived or the tank float valve is broken: deal with the supply first. If the tank is empty but the pump keeps running, the low-level (dry-run) float switch is wrongly installed or faulty; see the lesson Rooftop tank overflowing or not filling: checking mechanical and electric float switches.
Shallow borehole or dug well: the water level when the well is resting differs from the level while pumping. In a weak well, after a few minutes of pumping the water level drops below the strainer or beyond the pump’s suction lift. Signs: water comes when first switched on, then weakens, becomes frothy and stops; after a rest, switching on again gives a little water. Measure with a cord tied to a weight lowered from the top of the well, marking the water level at rest and while pumping.
If the water source is not enough, repairing the pump is pointless: wait for the supply, lower the strainer if there is still depth, or advise the owner to change to a suitable type of pump (deep-well jet pump, submersible pump) after a survey by someone who specialises in well pumps.

Figure 1. An orange-red pump drawing groundwater in Dong Hoa, Phu Yen: the grey plastic suction pipe runs straight up from the ground to the suction inlet, and the joints have been wrapped with extra black rubber; a single leaking joint on the suction side is enough for the pump to draw air and lose water. (Photo: Nghiem DangVi, Wikimedia Commons, CC BY 3.0, cropped)
Step 2. Prime the pump correctly
Isolate the power. Never pour in priming water while the pump is energised.
Open the priming plug (usually on top of the pump body, near the delivery outlet) and wipe around it.
Open a tap or valve on the delivery side (if there is one) so the air has somewhere to escape.
Pour in clean water slowly until it is full to overflowing with no more air bubbles. For a non-self-priming pump, the water must also fill the suction pipe; if you keep pouring and the level keeps dropping, the foot valve is leaking or the suction pipe is holed (go to Steps 3 and 4).
Check the priming plug washer and tighten by hand. A priming plug with a missing washer is also a place where air gets in.
Dry your hands and the area around the pump, stand on a dry spot, switch on the power and observe.
If no water comes within the time allowed by the manufacturer, switch off, let it cool, check it and only then prime again. If priming twice does not work, go and look for the leak; do not keep priming.
Reading the result:
After priming it runs normally for many days: the cause was the earlier loss of water (tank ran dry, water cut off, pipe removed).
It loses its prime again overnight: the foot valve is leaking or the suction pipe has a small air leak.
No water at all, or water for a few seconds and then nothing: a large air leak, a blocked strainer, the pump mounted too high, or the water level has dropped below the strainer.
Note: do not run the pump dry “to see whether it will pick up”. The mechanical seal on the pump shaft is cooled by the water in the pump itself; when it runs dry, the seal faces heat up very quickly and can burn or crack, after which water leaks at the shaft. There is no such thing as “a safe dry-running time”; if no water comes, switch off.
Step 3. Check the strainer and foot valve
The strainer has both a debris screen and a non-return valve that lets water go up and holds it when the pump stops. It fails in two opposite ways:
Blocked screen, valve stuck shut (algae, mud, plastic bags, sediment; strainer lying on the bottom sucking up mud): the pump spins but delivers nothing or very little, and may make a grinding, gravelly noise.
Valve stuck open, not sealing (debris caught on the valve seat, broken spring, hardened rubber disc): it runs, but loses its prime every time it is switched off.
How to check:
Isolate the power. Undo the union at the suction inlet (if there is one) so you do not have to drag the whole pump.
Pull the suction pipe up from the top of the tank or well by hand, with a rope or hook, with a helper. Do not climb in.
Wash the screen and clear debris from the valve opening. Press the valve disc: it should open easily and close by itself when released.
Seal test: stand the suction pipe upright with the strainer at the bottom and fill it with water from the top. The water must stay put; if it leaks at the strainer or drops gradually, the valve is not sealing.
If the valve is torn, the spring broken or the body cracked, replace the strainer with one matching the suction pipe size.
When you lower it back, keep the strainer submerged below the lowest water level and clear of the bottom so it does not draw in sediment (see the pump or strainer instructions for the distance); hang it securely so the strainer does not lie on the bottom. If the tank has a lot of sediment, recommend cleaning and flushing the underground tank.

Figure 2. The end of a blue ribbed flexible suction hose fitted with a strainer basket, hung on a red rope and fully submerged in the water. The photo shows fire brigade water-suction equipment, but the principle is the same as a household pump strainer: it must be submerged, have a debris screen and not be buried in the mud at the bottom. (Photo: Stefan-Xp, Wikimedia Commons, CC BY-SA 3.0)
Don’t forget the delivery side
If the non-return valve on the delivery pipe is fitted against the direction of the arrow or stuck shut, the delivery isolating valve has been closed by someone by mistake, or the filter cartridge is blocked, the pump still runs, the delivery pipe is hard, and no water flows. Checking these points takes a few minutes, so do it early.

Figure 3. A brass spring check valve with an arrow engraved on the body showing the direction of flow. The arrow must point in the direction the water travels: from the source to the pump on the suction side, and from the pump up to the tank on the delivery side. (Photo: SilverBullet X, Wikimedia Commons, CC0)
Step 4. Find the air leak on the suction pipe
If the strainer is fine but the pump still loses its prime, or delivers weakly with bubbles, suspect an air leak in the suction pipe. Common leak points:
The threaded joint at the pump suction inlet (not enough PTFE tape, plastic thread cracked from overtightening). For how to seal threads, see the lesson Wrapping PTFE tape on threaded water pipe joints correctly.
Unions with missing or hardened washers; hastily made solvent-welded joints on plastic pipe; the priming plug washer.
Buried pipe cracked by vehicles driving over it or by tree roots; old galvanised pipe corroded through.
Ordinary flexible hose (without a suction-resistant reinforcing core) collapsing when the pump runs.
How to find it:
Foam test: while the pump runs, brush thick soapy water or shaving foam onto each suction-side joint (keep your hands dry and keep water away from electrical parts). At the leak, the foam is sucked inwards or the sound of the pump changes.
Temporarily seal to narrow it down: switch off, wrap cling film and tape around the suspect joint, prime again and test run. If the delivery is much better, you have found the spot; afterwards the joint must be remade properly — do not leave the tape as a long-term repair.
After the pump is switched off, any suction-side joint that drips is also a clue.
The routing of the suction pipe also matters: the pipe should rise steadily towards the pump; a section with a hump will trap an air pocket. The suction pipe should not be smaller than the suction inlet, and should not be too long or have many square elbows. Any valve on the suction pipe must be fully open. Air drawn into the water also makes the taps in the house sputter; see the lesson Taps sputtering and intermittent flow caused by air in the pipes.
Step 5. Is the pump mounted too high, or the tank too high?
Suction lift: measure vertically from the lowest water level while pumping to the suction inlet and compare with the rating plate. The figure on the plate is for good conditions; with a long pipe and many elbows, the real figure is lower. If you are close to or above the limit, the pump delivers weakly, makes a gravelly noise or delivers nothing. Fixes: lower the strainer, move the pump closer to the source in a dry, well-ventilated place, or change the type of pump. Do not dig a deep pit and put the pump at the bottom to “reduce the height”: the pit collects water, creating an electrical hazard and a danger for anyone going down to repair it.
Delivery head: if the pump draws water but the water does not reach the rooftop tank, the total height plus losses may be close to the maximum head (H max) on the rating plate; at that point the flow is almost zero. Sign: strong flow on the lower floors, nothing on the roof. The pump needs to be reselected using the manufacturer’s performance curve.
Step 6. Check the impeller
Only when the suction side, water source and heights are all fine but the delivery is still weak do you get to the impeller. Signs: flow gradually decreasing even when fully primed, unusual rubbing noises, water with a lot of sand or alum-like sediment; a strainer that lost its screen long ago.
Isolate the power, unplug, close the delivery valve and drain the water from the pump.
Turn the shaft by hand via the motor’s cooling fan (refit the fan cover before reconnecting the power). The shaft should turn lightly and evenly, without sticking or grittiness.
For pumps that can be dismantled, open the pump chamber according to the manual: look for debris, roots, sediment and rust; worn, chipped or cracked impeller.
Clean it; replace the pump casing gasket if it is hardened or torn, because a leaking gasket here also makes the pump draw air.
Badly worn impeller, leaking seal, noisy bearings: advise the owner to compare repair with replacement; replacing seals and removing impellers is best left to a pump repair technician.

Figure 4. A pump with its casing removed: the inside of the pump chamber is thickly coated with mineral scale mixed with rust, with the shaft end exposed in the middle; the disc-type impeller removed and placed in front is also rusty. According to the photographer, this scale most likely stopped the impeller from turning. (Photo: Matt, Wikimedia Commons, public domain)
Step 7. The electrical side: a job for the electrician
Weak capacitor (single-phase pumps): sluggish starting, not reaching full speed, heating up quickly, weak delivery. The capacitor should be replaced with the correct rating from the plate, by an electrician.
Low voltage (end of the supply line, small or long cables): the motor runs slowly and the pump is weak. Have an electrician measure it while the pump is running.
Running in reverse: mainly with three-phase motors connected with the wrong phase sequence; the pump still delivers some water but very weakly. Rare with single-phase pumps, unless the motor has just been rewound or wrongly reconnected. Compare the direction of the motor’s cooling fan with the arrow on the pump body; reversing the direction is done by an electrician.
Quick reference table
Symptom | Common cause | Check | Fix |
|---|---|---|---|
Runs smoothly, not a drop of water, body hot | Lost prime; tank or well dry | Check the water level from the tank opening; open the priming plug once the pump is cool | Wait for the supply; prime again; check the dry-run float switch |
Loses its prime again overnight | Foot valve leaking; small air leak in suction pipe | Pull up the strainer and test that it holds water; foam-test the joints | Clean or replace the strainer; remake the leaking joint |
Delivers, then weakens, froths and stops | Water level drops below the strainer; strainer too shallow | Measure the water level while pumping | Lower the strainer; advise changing the pump type |
Weak delivery, gravelly noise | Suction lift too high; strainer blocked; suction pipe small or long | Compare the height with the rating plate; clean the strainer | Lower the strainer, move the pump closer to the source; change to the correct pipe size |
Delivery pipe hard, no water comes out | Isolating valve closed; check valve reversed or stuck; filter cartridge blocked | Check the arrow, isolating valve, filter cartridge | Open the valve; fit in the correct direction; replace the cartridge |
Draws well but does not reach the rooftop tank | Delivery head close to H max | Compare with the rating plate; test on a lower floor | Reselect the pump |
Shaft stiff, flow decreasing gradually | Impeller jammed with debris, scaled up, worn | Turn the shaft by hand (power isolated) | Clean; replace the impeller, gasket or pump |
Turns slowly, hot; three-phase pump delivering very weakly | Weak capacitor; low voltage; reverse rotation | Electrician measures | Electrician fixes |
Real-life examples
Case 1. Underground tank pump that needs priming every morning
In the afternoon the pump fills the tank normally; the next morning, switching it on gives no water and it has to be primed. After priming it delivers immediately, which rules out an empty tank and excessive suction lift. Pulling the suction pipe up from the tank opening, the plumber found a scrap of plastic bag loosely caught on the valve disc in the strainer; water poured into the pipe drained away within a few minutes. The valve disc was deformed, so the strainer was replaced with a new one of the same pipe size, hung securely clear of the bottom, and the owner was advised to clean the screen regularly.
Case 2. Shallow borehole that only runs for a few minutes in the dry season
In the rainy season the pump runs well; in the dry season it delivers for a few minutes, then weakens, froths and stops. Measuring with a cord: at rest the water level is still high, but while pumping it drops much further; combined with a long suction pipe and two square elbows, the real suction lift exceeded what the pump could manage. Advice: reduce the elbows and change the suction pipe to match the suction inlet size; if that does not help, invite a well pump installer to survey and recommend a suitable type of pump.
Case 3. New pump fitted, weak delivery with air bubbles
The owner replaced the pump himself, the delivery was weaker than the old pump and the taps upstairs sputtered. A soapy foam test with the pump running showed the foam being sucked in right at the suction inlet thread: the plastic fitting had cracked at its base from being overtightened with a spanner. After replacing the fitting and wrapping PTFE tape in the correct direction, the pump ran normally.
Safety checklist
Isolate the power before touching the pump: switch off the circuit breaker, unplug it and tell the household not to switch it back on. Do not rely on the switch or the float switch.
Never touch a wet pump, cables or junction box while they are live; do not stand on a flooded floor while equipment is energised.
The pump circuit should have RCD/RCBO shock protection and earthing of the casing; press the RCD’s TEST button regularly. If it is missing or trips repeatedly: call an electrician (see the lesson Wiring a water heater safely: RCBO, RCD and earthing).
Do not let the pump run dry; recommend a dry-run float switch or dry-running protection device.
Pump hot after running dry: let it cool before opening the priming plug, stand to one side and wear gloves.
Underground tanks and wells are confined spaces: there may be a lack of oxygen, toxic gases, slippery surfaces and depth. Never climb down into them, and do not lean your head deep into the opening. Any work that requires entering must be done by a company with the equipment and procedures for confined-space entry.
When the tank or well lid is open, guard the opening, especially in homes with small children; close it again as soon as you finish. Pull long pipes up with a helper and do not stand right at the edge.
Leave the electrical side (capacitor, cables, motor, phase reversal) to an electrician.
Frequently asked questions
Does a self-priming pump need priming water?
Yes. A self-priming pump can only evacuate the air in the suction pipe by itself when the pump body already contains water. At first installation and whenever the pump body has run dry, you still have to prime it according to the manufacturer’s instructions.
Why does it lose its prime every time it is left overnight?
Usually because the non-return valve in the strainer does not seal or the suction pipe has a small air leak: when the pump stops, the water gradually drains back to the tank. Check the strainer first, then check the joints on the suction side.
How many metres deep can a pump draw water from?
The theoretical limit is about 10 m of water column at sea level (for reference); in practice it is always less. The correct figure is the suction lift on the pump’s rating plate, and you should leave a margin. Deeper wells need a different type of pump.
What does it mean when the pump makes a grinding noise as if it has gravel inside?
The most common cause is cavitation: the pressure on the suction side is too low (blocked strainer, small pipe, suction lift too high), so the water forms vapour bubbles that collapse inside the pump and, over time, pit the impeller. It may also be actual gravel or a failed bearing; check the suction side first, then isolate the power and turn the shaft by hand.
The pump accidentally ran dry for a while. Is it damaged?
Not necessarily. Let it cool, prime it again, test run and watch for water leaking at the shaft, unusual noises or the motor getting abnormally hot. A leak at the shaft means the seal is damaged and should be replaced soon.
Practice exercises
Draw a diagram of the suction side: draw the pipework from the strainer up to the pump suction inlet, label every joint, elbow and valve, and mark the places where air could get in.
Read the rating plate: note the suction lift, maximum head, flow rate and suction inlet size of two pumps; compare them with the real height from the water level to the pump and to the rooftop tank.
Test a strainer: stand an old strainer upright, fill it with water and see whether it holds; clean it, test again and record the results.
Practise priming (under supervision): go through all the steps of isolating the power, opening the plug, filling, checking the washer, closing the plug, switching on and observing.
Advisory role-play: the owner of a weak well wants to “fit a bigger pump to make it stronger”. Explain in 2 minutes why the well’s water level should be surveyed first.